Supporting HVAC Ventilation, ebm-papst A2D300-AP02-01 is a 400 V AC axial fan, noted for a listed airflow of 3,350 m³/h. The figure helps confirm design suitability. Its documented data supports integration planning.
| Rated Voltage(V) | 400 |
|---|---|
| Size(mm) | 300 |
| Max.Air Flow(m³/h) | 3350 |
| Max.Pressure(Pa) | 125 |
| Input Power(W) | 300 |
| Speed(rpm) | 2750 |
| Noise(db) | 71 |
The ebm-papst A2D300-AP02-01 is an AC axial fan for hvac systems, supporting equipment thermal management and integration.
Data includes 400 V operation, airflow up to 3350 m³/h and pressure up to 125 Pa for comparing the documented operating point with the intended air channel. Listed noise is 71 dB at the stated test point. The datasheet lists ball-bearing support for durable motor support. Correct wiring and unobstructed inlet clearance help preserve cooling efficiency, operating stability and service life.
Procurement teams should validate A2D300-AP02-01 against the actual system resistance, electrical connection, fit and environmental limits. Its selection record guides procurement screening during specification review with clearer fit and interface checks.
Continuous operation must remain within the published electrical, thermal and aerodynamic limits; confirm the exact datasheet and system conditions.
Its AC axial fan configuration and a listed airflow of 3,350 m³/h provide model-specific criteria for matching HVAC Ventilation systems.
The supplied table lists 3,350 m³/h, 125 Pa, 2,750 rpm; use the exact datasheet for the complete operating curve.
Verify mounting orientation, inlet and outlet clearance, fastener security, electrical connections and the exact dimensional drawing before startup.

Used in HVAC Ventilation, ebm-papst A2D300-AP02-02 is a 400 V AC axial fan, defined by a listed airflow of 3,350 m³/h. The data helps compare W-series variants. Its documented data supports integration planning.
Read More
A4E350-AP06-33 is a 230 VAC axial fan for data-communications equipment, heat pumps, ventilation systems. Its main supplied feature is 3110 m³/h maximum airflow stated for this model. It also lists a 350 mm size specified in the upload data. Review duct connection for ductwork design.
Read More
A2D250-AA06-84 is a 265 VAC axial fan for data-communications equipment, heat pumps, ventilation systems. Its main supplied feature is 150 W input power for the listed electrical version. It also lists a 250 mm size specified in the upload data. Review system resistance for equipment design.
Read More
A6D800-AA01-01 is a 400 VAC axial fan for data-communications equipment, heat pumps, ventilation systems. Its main supplied feature is 2780 W input power for the listed electrical version. It also lists a 800 mm size specified in the upload data. Review procurement specification for final model confirmation.
Read More
A6D800-AE05-03 is a 480 VAC axial fan for data-communications equipment, heat pumps, ventilation systems. Its main supplied feature is 1080 rpm rated speed in the supplied parameter row. It also lists a 800 mm size specified in the upload data. Review replacement fit for ductwork design.
Read More
A2D250-AA02-02 is a 400 VAC axial fan for data-communications equipment, heat pumps, ventilation systems. Its main supplied feature is axial airflow intended for low-to-moderate system resistance. It also lists a 250 mm size specified in the upload data. Review airflow path for commissioning review.
Read More