| Mfr Part # | Rated Voltage(V) | Size(mm) | Max.Air Flow(m³/h) | Max.Pressure(Pa) | Input Power(W) | Speed(rpm) | Noise(db) | |
|---|---|---|---|---|---|---|---|---|
![]() UF-15PC23BTH | Fulltech 230VAC 29W AC Axial Fan for HVAC and Industrial Equipment Cooling Aimed at HVAC, refrigeration, heat exchangers, and industrial cooling, the Fulltech UF-15PC23BTH uses a 230 VAC AC axial fan architecture within 150 × 172 × 51 mm. Terminal connection distinguishes this version, alongside a die-cast frame, ball bearings, and protection. Rated data: 29 W input, up to 384 m³/h, 3400 rpm, 58 dB. |
230 | 172*150*51 | 384 | - | 29 | 3400 | 58 | |
![]() UF-15P23BWH | Fulltech 230VAC 30W AC Axial Fan for Control Cabinet and Power Supply Cooling industrial cabinets and power supplies is the target duty for UF-15P23BWH, a 230 VAC AC axial fan measuring 150 × 172 × 51 mm. Ball-bearing construction is the central durability detail, paired with lead-wire connection and motor protection. Rated data: 30 W input, up to 332 m³/h, 3100 rpm, 55 dB. |
230 | 172*150*51 | 332 | - | 30 | 3100 | 55 | |
![]() UF-15KC23BTH | Fulltech 230VAC 38W AC Axial Fan for HVAC and Industrial Equipment Cooling Built around 150 × 172 × 55 mm, the UF-15KC23BTH uses a 230 VAC AC axial fan arrangement for HVAC and industrial cooling. Its die-cast aluminum frame is the representative structural feature; ball bearings and terminal connection are also documented. Rated data: 38 W input, up to 498 m³/h, 3400 rpm, 60 dB. |
230 | 172*150*55 | 498 | - | 38 | 3400 | 60 | |
![]() UF-15AC23BTH | Fulltech 230VAC 26W AC Axial Fan for HVAC and Industrial Equipment Cooling Fulltech UF-15AC23BTH provides 230 VAC AC axial fan cooling for HVAC and industrial cooling from a 150 × 172 × 38 mm format. Motor protection is a key selection detail, supported by a die-cast frame, ball bearings, and terminal connection. Rated data: 26 W input, up to 360 m³/h, 3400 rpm, 58 dB. |
230 | 172*150*38 | 360 | - | 26 | 3400 | 58 | |
![]() UF-12AM23BWHF | Fulltech 230VAC 15W AC Axial Fan for Control Cabinet and Power Supply Cooling The 230 VAC UF-12AM23BWHF is a 120 × 120 × 38 mm AC axial fan specified for industrial cabinets and power supplies. A die-cast frame and ball bearings define the mechanical design, while lead-wire connection supports integration. Rated data: 15 W input, up to 175 m³/h, 3100 rpm, 46 dB. |
230 | 120*120*38 | 175 | - | 15 | 3100 | 46 | |
![]() UF-12A23BWH | Fulltech 230VAC 17W AC Axial Fan for Control Cabinet and Power Supply Cooling Serving industrial cabinets and power supplies, the UF-12A23BWH combines 230 VAC operation with a 120 × 120 × 38 mm AC axial fan design. Lead-wire connection distinguishes this version, alongside a die-cast frame, ball bearings, and protection. Rated data: 17 W input, up to 180 m³/h, 3100 rpm, 46 dB. |
230 | 120*120*38 | 180 | - | 17 | 3100 | 46 | |
![]() UF-12A23BTH | Fulltech 230VAC 17W AC Axial Fan for Control Cabinet and Power Supply Cooling UF-12A23BTH is a 120 × 120 × 38 mm AC axial fan rated for 230 VAC and applied in industrial cabinets and power supplies. Ball-bearing construction is the central durability detail, paired with terminal connection and motor protection. Rated data: 17 W input, up to 180 m³/h, 3100 rpm, 46 dB. |
230 | 120*120*38 | 180 | - | 17 | 3100 | 46 |
The most reliable way to specify AC Fan is to work from the system, not from the catalog. Measure or calculate the airflow and pressure demand first, add the dimensional limits of the mounting position, and only then shortlist series whose curves cover your operating point with margin.
Electrical matching is the next gate. Confirm the supply voltage — 12 V, 24 V or 48 V DC for compact electronics cooling, 115 V or 230 V AC for equipment and panel cooling — and decide whether you need speed control. EC models accept PWM or 0-10 V signals and report speed through a tachometer output, which makes them the default choice for variable-airflow systems, while AC units remain a cost-effective answer for fixed-speed duty.
Then filter by environment. High ambient temperature, dust or moisture loads dictate the IP rating and bearing choice — ball bearings keep airflow and noise stable over years, while sleeve bearings suit light-duty horizontal mounting. Regulatory needs such as UL, CE and RoHS recognition should be confirmed before the shortlist goes to purchasing, together with a maximum allowed sound pressure level in dBA.
End the process by checking supply, not just specification: confirm current stock, the lead time for follow-up quantities, and obtain datasheets and dimension drawings so the mechanical interface is verified before the PO. Send us your airflow and pressure requirements and our engineers will confirm the best-matched series — 27 products are available in this category today.
The daily work of our sales engineers is built around AC Fan used in data center cooling, refrigeration and cold chain projects, building ventilation, telecom base stations, medical devices and industrial control cabinets — environments where a stopped fan is a stopped business process. That daily exposure to real installations is exactly what we bring back into every selection: not just reading curves, but knowing which models survive dust, heat, continuous duty and restricted service access.
A typical case: an equipment builder needed to replace an aging AC fan inside a control cabinet that could not be taken offline for more than an hour. By cross-referencing the frame dimensions, voltage and airflow curve, we supplied a current-series drop-in replacement with a matching tachometer signal, and the swap was completed during a scheduled maintenance window.
Refrigeration and cold chain customers bring us another pattern: the failed condenser fan is unavailable for weeks. Comparing diameter, speed, bearings and IP rating, we supply a functionally equivalent unit from stock so the system returns to duty the same week — the reason many service companies keep our contact number on file.
From one-piece emergency replacements to volume supply for equipment manufacturers, every FULLTECH enquiry is handled by the same rule: verify the parameters first, then quote — so what arrives on site is the fan the project actually needs.
Datasheets, performance curves, dimension drawings and certification files (UL, CE, RoHS where applicable) are available on request before you buy — we believe a purchase order should follow a verified selection, not replace it. For project tenders we can also provide product comparison tables that put the candidate models side by side on the parameters you care about.
Common series and mainstream voltage versions are normally in stock and can ship within a few working days; specialized or customized variants are produced to order and typically require additional production time. Send us the exact model or the required parameters and we will confirm stock, unit price and the earliest shipment date in one reply Currently 27 products in this category are listed online.
Yes. Replacement supply is one of our core services: we cross-reference the mounting dimensions, voltage, speed and performance curve of your installed unit and propose the closest current-series equivalent. Where the frame or connector differs slightly, we state the difference clearly before you order, so the replacement installs without surprises.
Bag
Bag packaging indicates that a specified quantity of product is packaged by the manufacturer in a bag, sealed pouch, or similar container and sold as a unit without repackaging. It is also used to describe kits/assortments where components are packaged in separate bags according to part number or parametric value, rather than in a compartmentalized box or similar rigid container.