Get Quote
Home > Products > By brand > SUNON > AC Fans

AC Fans

By type

By industry

Rated Voltage(V)

Size(mm)

Max.Air Flow(m³/h)

Max.Pressure(Pa)

Input Power(W)

Speed(rpm)

Noise(db)

Stocking Options

Environmental Options

Media

Exclude

45 results

Applied Filters

Showing
1-20
1-20 21-40 41-45
of 45
Download Table
Mfr Part # Rated Voltage(V) Size(mm) Max.Air Flow(m³/h) Max.Pressure(Pa) Input Power(W) Speed(rpm) Noise(db)
DP201AT 2122HBT.GN | SUNON 220–240VAC 18/16.5W 120×120×25mm AC Axial Fan for data center cooling

DP201AT 2122HBT.GN is a 220–240 VDC axial fan for servers, data-communications equipment, control cabinets. Its main supplied feature is 2150 / 2500 rpm rated speed in the supplied parameter row. It also lists a 120×120×25 mm size specified in the upload data. Review power budget for application engineering.

220–240 120×120×25 112.13 / 135.92 34.87 / 42.35 18 / 16.5 2150 / 2500 44 / 48
MA2072-HVL.GN | SUNON 220VAC 4.4W AC Axial Fan for servers and data communications equipment

MA2072-HVL.GN is a 220 VAC axial fan for servers, data-communications equipment, control cabinets. Its main supplied feature is 29 m³/h maximum airflow stated for this model. It also lists a 70*70*25 mm size specified in the upload data. Review operating point for ductwork design. Check the exact variant before ordering.

220 70*70*25 29 - 4.4 3900 31
DP200A 2123XBT.GN | SUNON 220-240VAC 21W 120x120x38mm AC Axial Fan for data center cooling

DP200A 2123XBT.GN is a 220-240 VDC axial fan for servers, data-communications equipment, control cabinets. Its main supplied feature is 21 W input power for the listed electrical version. It also lists a 120*120*38 mm size specified in the upload data. Review procurement specification for motor selection.

220-240 120*120*38 198.9 97.1 21 3150 50
DP201A 2123HBT.GN | SUNON 220–240VAC 20/19W 120×120×38mm AC Axial Fan for data center cooling

DP201A 2123HBT.GN is a 220–240 VDC axial fan for servers, data-communications equipment, control cabinets. Its main supplied feature is 45 / 50 dB noise data recorded for this model. It also lists a 120×120×38 mm size specified in the upload data. Review system resistance for commissioning review.

220–240 120×120×38 147.81 / 181.79 64.76 / 79.71 20 / 19 2750 / 3050 45 / 50
A2175-HBT TC.GN | SUNON 220VAC 25W AC Axial Fan for servers and data communications equipment

A2175-HBT TC.GN is a 220 VAC axial fan for servers, data-communications equipment, control cabinets. Its main supplied feature is a 172*150*51 mm size specified in the upload data. It also lists 203 m³/h maximum airflow stated for this model. Review duct connection for commissioning review.

220 172*150*51 203 - 25 2800 51
SF23080A 2083HBL.GN | SUNON 240VAC 13.5W 80x80x38mm AC Axial Fan for data center cooling

SF23080A 2083HBL.GN is a 240 VAC axial fan for servers, data-communications equipment, control cabinets. Its main supplied feature is 13.5 W input power for the listed electrical version. It also lists a 80x80x38 mm size specified in the upload data. Review performance curve for site verification.

240 80x80x38 52.67 47.33 13.5 2850 36.5
SF23092A/2092HBL.GN | SUNON 220–240VAC 14.5/14W 92×92×25mm AC Axial Fan for data center cooling

SF23092A/2092HBL.GN is a 220–240 VDC axial fan for servers, data-communications equipment, control cabinets. Its main supplied feature is a 92×92×25 mm size specified in the upload data. It also lists 50.97 / 62.86 m³/h maximum airflow stated for this model. Review air direction for project specification.

220–240 92×92×25 50.97 / 62.86 32.38 / 47.33 14.5 / 14 2350 / 2850 37 / 40
SP100A 1123XBT.GN | SUNON 115VAC 22/20W 120×120×38mm AC Axial Fan for data center cooling

SP100A 1123XBT.GN is a 115 VAC axial fan for servers, data-communications equipment, control cabinets. Its main supplied feature is axial airflow intended for low-to-moderate system resistance. It also lists a 120×120×38 mm size specified in the upload data. Review performance curve for project specification.

115 120×120×38 164.8 / 198.78 84.69 / 97.14 22 / 20 2850 / 3150 45 / 50
SF23080AT 2082HBL.GN | SUNON 220VAC 13.5W 80x80x25mm AC Axial Fan for data center cooling

SF23080AT 2082HBL.GN is a 220 VAC axial fan for servers, data-communications equipment, control cabinets. Its main supplied feature is axial airflow intended for low-to-moderate system resistance. It also lists a 80*80*25 mm size specified in the upload data. Review operating point for maintenance planning.

220 80*80*25 - - 13.5 2900 -
DP201AT 2122HBL.GN | SUNON 220/240VAC 19W 120x120x25mm AC Axial Fan for data center cooling

DP201AT 2122HBL.GN is a 220/240 VDC axial fan for servers, data-communications equipment, control cabinets. Its main supplied feature is axial airflow intended for low-to-moderate system resistance. It also lists a 120*120*25 mm size specified in the upload data. Review system resistance for maintenance planning.

220/240 120*120*25 136 42.3 19 2500 48
A2175-HBL TC.GN | SUNON 220VAC 25W AC Axial Fan for servers and data communications equipment

A2175-HBL TC.GN is a 220 VAC axial fan for servers, data-communications equipment, control cabinets. Its main supplied feature is a 172*150*51 mm size specified in the upload data. It also lists 203 m³/h maximum airflow stated for this model. Review procurement specification for equipment design.

220 172*150*51 203 - 25 2800 51
DP200A 2123XBL.GN | SUNON 220-240VAC 21W 119x119x38.5mm AC Axial Fan for data center cooling

DP200A 2123XBL.GN is a 220-240 VDC axial fan for servers, data-communications equipment, control cabinets. Its main supplied feature is 3150 rpm rated speed in the supplied parameter row. It also lists a 119x119x38.5 mm size specified in the upload data. Review duct connection for equipment design.

220-240 119x119x38.5 198.8 97.1 21 3150 50
DP200A-2123HSL | SUNON 220VAC AC Axial Fan for servers and data communications equipment

DP200A-2123HSL is a 220 VAC axial fan for servers, data-communications equipment, control cabinets. Its main supplied feature is axial airflow intended for low-to-moderate system resistance. It also lists a 120*120*38 mm size specified in the upload data. Review operating point for replacement review.

220 120*120*38 - - - - -
SF11592A-1092HBL.GN | SUNON 115V 13W 92x92x25mm 2350rpm AC Axial Fan for HVAC & Ventilation

Within commercial refrigeration and refrigerator cooling, SUNON SF11592A-1092HBL.GN serves as a 92 × 92 × 25 mm AC axial fan operating at 115 VAC. Its 2350 rpm rating defines a lower-speed operating point. For project documentation, start with the supplied application data. Reconcile the model code with the required electrical interface.

115 92x92x25mm - 32.4 13 2350 -
SF11580A-1083HBL.GN | SUNON 115V 14W 80x80x38mm 2400rpm AC Axial Fan for HVAC & Ventilation

The 80 × 80 × 38 mm SF11580A-1083HBL.GN brings 115 VAC AC axial fan cooling to commercial refrigeration and refrigerator cooling. Its 2400 rpm rating defines a lower-speed operating point. Use the documented technical profile when planning project documentation. Reconcile the model code with the required electrical interface.

115 80x80x38mm - 32.4 14 2400 -
SF23092A-2092HBL.GN | SUNON 240V 14W Square-91.5Lx91.5Hmm AC Axial Fan for HVAC & Ventilation

The SF23092A-2092HBL.GN is SUNON's 240 VAC, Square - 91.5mm L × 91.5mm H mm AC axial fan option for commercial refrigeration and refrigerator cooling. Its 2850 rpm rating defines a lower-speed operating point. Review its model record during project documentation. Reconcile the model code with the required electrical interface.

240 Square - 91.5mm L x 91.5mm H 62.4 47.3 14 2850 40
SF23080A-2083HBL.GN | SUNON 240V 13.5W 80x80x38mm 52.67m3/h AC Axial Fan for HVAC & Ventilation

SF23080A-2083HBL.GN addresses commercial refrigeration and refrigerator cooling through a 240 VAC AC axial fan platform measuring 80 × 80 × 38 mm. Its 2850 rpm rating defines a lower-speed operating point. Treat the product configuration as a primary input to project documentation. Reconcile the model code with the required electrical interface.

240 80x80x38 52.67 47.33 13.5 2850 36.5
SF23080AT-2082HBL.GN | SUNON 240V 13.5W 80x80x25.50mm AC Axial Fan for Refrigeration Equipment

SUNON SF23080AT-2082HBL.GN combines a 80 × 80 × 25.50 mm AC axial fan platform with a 240 VAC rating for commercial refrigeration and refrigerator cooling. Its 2900 rpm rating defines a lower-speed operating point. Base project documentation on the stated system interface. Reconcile the model code with the required electrical interface.

240 80x80x25.50 37 47.3 13.5 2900 34.5
SF11592A-1092HBL | SUNON 115V 13W 92x92x25mm 2350rpm AC Axial Fan for HVAC & Ventilation

Built around commercial refrigeration and refrigerator cooling, SUNON SF11592A-1092HBL is a 115 VAC AC axial fan in a 92 × 92 × 25 mm frame. Its 2350 rpm rating defines a lower-speed operating point. During project documentation, compare the model's cooling specification. Reconcile the model code with the required electrical interface.

115 92x92x25mm - 32.4 13 2350 -
DP201AT-2122HBL.GN | SUNON 220V 19W 119x119x25.50mm 2500rpm AC Axial Fan for HVAC & Ventilation

Within commercial refrigeration and refrigerator cooling, SUNON DP201AT-2122HBL.GN serves as a 119 × 119 × 25.50 mm AC axial fan operating at 220 VAC. Its 2500 rpm rating defines a lower-speed operating point. The recorded duty-point values should guide project documentation. Reconcile the model code with the required electrical interface.

220 119x119x25.50 134.4 42.3 19 2500 48
Showing
1-20
1-20 21-40 41-45
of 45
1 2 3
GO page

About AC Fans

How to Select the Right AC Fans

The most reliable way to specify AC Fans is to work from the system, not from the catalog. Measure or calculate the airflow and pressure demand first, add the dimensional limits of the mounting position, and only then shortlist series whose curves cover your operating point with margin.

Electrical matching is the next gate. Confirm the supply voltage — 12 V, 24 V or 48 V DC for compact electronics cooling, 115 V or 230 V AC for equipment and panel cooling — and decide whether you need speed control. EC models accept PWM or 0-10 V signals and report speed through a tachometer output, which makes them the default choice for variable-airflow systems, while AC units remain a cost-effective answer for fixed-speed duty.

Then filter by environment. High ambient temperature, dust or moisture loads dictate the IP rating and bearing choice — ball bearings keep airflow and noise stable over years, while sleeve bearings suit light-duty horizontal mounting. Regulatory needs such as UL, CE and RoHS recognition should be confirmed before the shortlist goes to purchasing, together with a maximum allowed sound pressure level in dBA.

End the process by checking supply, not just specification: confirm current stock, the lead time for follow-up quantities, and obtain datasheets and dimension drawings so the mechanical interface is verified before the PO. Send us your airflow and pressure requirements and our engineers will confirm the best-matched series — 45 products are available in this category today.

Typical Applications and Use Cases for AC Fans

The daily work of our sales engineers is built around AC Fans used in data center cooling, refrigeration and cold chain projects, building ventilation, telecom base stations, medical devices and industrial control cabinets — environments where a stopped fan is a stopped business process. That daily exposure to real installations is exactly what we bring back into every selection: not just reading curves, but knowing which models survive dust, heat, continuous duty and restricted service access.

A typical case: an equipment builder needed to replace an aging AC fan inside a control cabinet that could not be taken offline for more than an hour. By cross-referencing the frame dimensions, voltage and airflow curve, we supplied a current-series drop-in replacement with a matching tachometer signal, and the swap was completed during a scheduled maintenance window.

Refrigeration and cold chain customers bring us another pattern: the failed condenser fan is unavailable for weeks. Comparing diameter, speed, bearings and IP rating, we supply a functionally equivalent unit from stock so the system returns to duty the same week — the reason many service companies keep our contact number on file.

From one-piece emergency replacements to volume supply for equipment manufacturers, every SUNON enquiry is handled by the same rule: verify the parameters first, then quote — so what arrives on site is the fan the project actually needs.

Frequently Asked Questions About Buying AC Fans

What technical documentation do you provide before purchase?

Datasheets, performance curves, dimension drawings and certification files (UL, CE, RoHS where applicable) are available on request before you buy — we believe a purchase order should follow a verified selection, not replace it. For project tenders we can also provide product comparison tables that put the candidate models side by side on the parameters you care about.

Do you have AC Fans in stock and how fast can you deliver?

Common series and mainstream voltage versions are normally in stock and can ship within a few working days; specialized or customized variants are produced to order and typically require additional production time. Send us the exact model or the required parameters and we will confirm stock, unit price and the earliest shipment date in one reply Currently 45 products in this category are listed online.

Can you replace my existing AC Fans from another supplier or a discontinued model?

Yes. Replacement supply is one of our core services: we cross-reference the mounting dimensions, voltage, speed and performance curve of your installed unit and propose the closest current-series equivalent. Where the frame or connector differs slightly, we state the difference clearly before you order, so the replacement installs without surprises.

Bag

Bag packaging indicates that a specified quantity of product is packaged by the manufacturer in a bag, sealed pouch, or similar container and sold as a unit without repackaging. It is also used to describe kits/assortments where components are packaged in separate bags according to part number or parametric value, rather than in a compartmentalized box or similar rigid container.