| Mfr Part # | Rated Voltage(V) | Size(mm) | Max.Air Flow(m³/h) | Max.Pressure(Pa) | Input Power(W) | Speed(rpm) | Noise(db) | |
|---|---|---|---|---|---|---|---|---|
![]() R2K150-AC01-33 | ebm-papst 230V 32W AC Hot-Air Blower for Hot-Air Systems Built for Hot-Air Systems, the ebm-papst R2K150-AC01-33 is a 230 V AC forward-curved centrifugal fan, built around a documented 32 W input rating. This supports technical purchasing review. |
230 | 150 | - | - | 32 | 2000 | - | |
![]() RL90-18/06 | ebm-papst 115V 19.5W Centrifugal Blower for Equipment Cooling Matched to Equipment Cooling, the ebm-papst RL90-18/06 is a 115 V AC forward-curved centrifugal fan, documented with a documented 19.5 W input rating. It provides a traceable selection parameter. |
115 | 121*121*37 | 42 | 120 | 19.5 | 2550 | - | |
![]() WSFAN230 | ebm-papst 230V 13W AC Cooling Fan for ABB Inverter Drives Created for ABB Inverter Drives, the ebm-papst WSFAN230 is a 230 V AC forward-curved centrifugal fan, presenting a documented speed of 5,500 rpm. It supports an evidence-based shortlist. |
230 | - | - | - | 13 | 5500 | - | |
![]() RRL152/0020A72-3020LH-503 | ebm-papst 230V 42W Centrifugal Blower for HVAC Applied in HVAC, the ebm-papst RRL152/0020A72-3020LH-503 is a 230 V AC forward-curved centrifugal fan, documented with a documented 42 W input rating. This supports duty-point selection. |
230 | - | - | - | 42 | 2300 | - | |
![]() RLA97/0034-3612-020299 | ebm-papst Centrifugal Blower for Boilers Applied in Boilers, the ebm-papst RLA97/0034-3612-020299 is a 0 V AC forward-curved centrifugal fan, centered on model-specific construction for its stated cooling duty. The value helps verify equipment fit. |
0 | - | - | - | - | - | - | |
![]() RG90-18/56 | ebm-papst 230V 22W Centrifugal Blower for Boilers Designed for Boilers, ebm-papst RG90-18/56 is a 230 V AC forward-curved centrifugal fan, noted for a documented 22 W input rating. This supports duty-point selection. Its documented data supports integration planning. |
230 | 135*135*38 | 54 | - | 22 | 2200 | - | |
![]() RG128/1300-3612-030204 | ebm-papst 230V 92W Centrifugal Blower for Boilers Suited to Boilers, the ebm-papst RG128/1300-3612-030204 is a 230 V AC forward-curved centrifugal fan, documented with a documented 92 W input rating. The data supports model-level evaluation. |
230 | - | - | - | 92 | - | - | |
![]() RG125-19/96 | ebm-papst 230V 20W Centrifugal Blower for Boilers Intended for Boilers, the ebm-papst RG125-19/96 is a 230 V AC forward-curved centrifugal fan, with a focus on a documented 20 W input rating. It gives engineers a clear comparison point. |
230 | 180*180*33.5 | 86 | - | 20 | 2 550 | - | |
![]() RG175/2000-3633-010204 | ebm-papst 230V 240W Centrifugal Blower for Boilers Designed for Boilers, the ebm-papst RG175/2000-3633-010204 is a 230 V AC forward-curved centrifugal fan, defined by 175 mm dimensions for installation planning. The data helps compare K-series variants. |
230 | 175 | - | - | 240 | - | - | |
![]() RG160-28/56S | ebm-papst 230V 47W Centrifugal Blower for Boilers Engineered around Boilers, ebm-papst RG160-28/56S is a 230 V AC forward-curved centrifugal fan, noted for a documented 47 W input rating. The data supports model-level evaluation. Its documented data supports integration planning. |
230 | - | 188 | 335 | 47 | 2750 | - | |
![]() RG148/1200-3633-010212 | ebm-papst 230-240V 300W Centrifugal Blower for Boilers Selected for Boilers, the ebm-papst RG148/1200-3633-010212 is a 230-240V AC forward-curved centrifugal fan, whose supplied data highlights a documented 300 W input rating. The rating aids system-fit checks. |
230/240 | - | - | - | 300 | - | - | |
![]() RG128/1300-3612-030206 | ebm-papst 230V 92W Centrifugal Blower for Boilers Selected for Boilers, the ebm-papst RG128/1300-3612-030206 is a 230 V AC forward-curved centrifugal fan, with a focus on a documented 92 W input rating. It gives engineers a clear comparison point. |
230 | - | - | - | 92 | - | - | |
![]() RG125-19/56 | ebm-papst 230V 20W Centrifugal Blower for Boilers Built for Boilers, ebm-papst RG125-19/56 is a 230 V AC forward-curved centrifugal fan, with a focus on a documented 20 W input rating. It gives engineers a clear comparison point. Its documented data supports integration planning. |
230 | - | 80 | - | 20 | 2550 | - | |
![]() R2S133-AE17-05 | ebm-papst 230V 34W Centrifugal Fan for Automation Intended for Automation, the ebm-papst R2S133-AE17-05 is a 230 V AC forward-curved centrifugal fan, distinguished by 133 mm dimensions for installation planning. The rating clarifies its operating profile. |
230 | 133 | 320 | 180 | 34 | 3200 | - | |
![]() R2S175-AA07-39 | ebm-papst 230V 57W Centrifugal Fan for Automation Selected for Automation, the ebm-papst R2S175-AA07-39 is a 230 V AC forward-curved centrifugal fan, characterized by 175 mm dimensions for installation planning. The value helps verify equipment fit. |
230 | 175 | 450 | 100 | 57 | 2440 | - | |
![]() R2S175-AB56-56 | ebm-papst 230V 51W Centrifugal Fan for Cleanroom Used in Cleanroom, the ebm-papst R2S175-AB56-56 is a 230 V AC forward-curved centrifugal fan, whose supplied data highlights a documented 51 W input rating. The rating aids system-fit checks. |
230 | 175 | - | - | 51 | 2300 | - | |
![]() R2S175-AB56-01 | ebm-papst 230V 53W Centrifugal Fan for Automation Selected for Automation, the ebm-papst R2S175-AB56-01 is a 230 V AC forward-curved centrifugal fan, distinguished by a listed acoustic value of 55 dB. It provides a practical sizing reference. |
230 | 175 | 445 | 140 | 53 | 2350 | 55 | |
![]() R2S133-AE17-43 | ebm-papst 230V 38W Centrifugal Fan for Cleanroom Used in Cleanroom, the ebm-papst R2S133-AE17-43 is a 230 V AC forward-curved centrifugal fan, centered on 133 mm dimensions for installation planning. The value helps verify equipment fit. |
230 | 133 | - | - | 38 | 2950 | - | |
![]() R2E225-BD92-36 | ebm-papst 230V 200W Centrifugal Fan for Automation Configured for Automation, ebm-papst R2E225-BD92-36 is a 230 V AC forward-curved centrifugal fan, defined by a documented speed of 2,950 rpm. The value helps verify equipment fit. Its documented data supports integration planning. |
230 | 225 | 1350 | 450 | 200 | 2950 | - | |
![]() R2E250-AC09-05 | ebm-papst 230V 265W Centrifugal Fan for Automation Used in Automation, ebm-papst R2E250-AC09-05 is a 230 V AC forward-curved centrifugal fan, defined by a documented speed of 2,650 rpm. The value helps verify equipment fit. Its documented data supports integration planning. |
230 | 250 | - | - | 265 | 2650 | - |
Before comparing models of AC Forward, write down the real operating requirements: required airflow, system static pressure, available installation space and the electrical supply on site. A selection that ignores any of these four factors usually ends in returned goods or on-site retrofits.
Voltage and control define the shortlist. Standard options include 12/24/48 V DC and 115/230 V AC; for applications where operating points move, EC fans with PWM or 0-10 V input give precise speed control, and a tach signal provides the feedback many safety systems require.
Environmental conditions eliminate unsuitable models faster than any catalog filter. Check the ambient temperature range, required IP protection for dust and moisture, and the expected service life — ball-bearing units hold their noise and airflow figures far longer than sleeve-bearing designs in vertical or high-temperature positions. If the equipment must ship into regulated markets, verify UL, CE and RoHS compliance at this stage, and set a realistic noise target in dBA so acoustic requirements do not surface after installation.
Close the selection by de-risking the order: verify stock levels, confirm production lead time, and request datasheets plus dimension drawings for the final candidates so the mounting holes and connectors are checked before purchase. Share your operating point with us and we will validate the fit 269 products in this category are ready for comparison.
Across our project record, AC Forward are specified wherever equipment must stay cool and air must keep moving: data centers and server rooms, commercial refrigeration, air handling and ventilation systems, telecom and battery cabinets, industrial machinery, and power electronics in the new-energy sector. What these projects share is a simple truth — the fan is small in cost but decisive for uptime, so it deserves the same engineering attention as the equipment it protects.
In a recent retrofit project, a customer's cooling unit had to keep running while its worn fan was exchanged. We identified a current-series replacement with identical mounting dimensions and an equivalent airflow-pressure curve, confirmed the tach output compatibility, and the installation was finished within a single maintenance window.
A second frequent case is refrigeration service: a condenser or evaporator fan fails and the exact original model is on long lead time. Instead of waiting, we check bearing type, IP rating, blade diameter and speed, then offer an equivalent that restores capacity immediately — one of the most common ways our stock protects cold chain operations.
New builds and replacement projects on ebmpapst equipment follow the same path at our company: you send the required airflow, pressure and dimensions; we respond with a shortlist, performance curves and firm delivery dates.
Yes. Replacement supply is one of our core services: we cross-reference the mounting dimensions, voltage, speed and performance curve of your installed unit and propose the closest current-series equivalent. Where the frame or connector differs slightly, we state the difference clearly before you order, so the replacement installs without surprises.
Single-piece orders and samples are welcome — many customers validate one unit in their system before committing to volume. There is no minimum order quantity for standard stock models, and the sample price is deducted from the bulk order in most repeat purchases. Tell us the quantity you plan to use and we will quote both scenarios.
Yes. Beyond catalogue models we can discuss modified lead wires, connectors, speed curves, IP upgrades or private-label packaging for OEM projects. Customization usually starts from a defined annual quantity; our engineers will review your requirement and confirm feasibility, tooling cost and lead time before any commitment.
Bag
Bag packaging indicates that a specified quantity of product is packaged by the manufacturer in a bag, sealed pouch, or similar container and sold as a unit without repackaging. It is also used to describe kits/assortments where components are packaged in separate bags according to part number or parametric value, rather than in a compartmentalized box or similar rigid container.