| Mfr Part # | Rated Voltage(V) | Size(mm) | Max.Air Flow(m³/h) | Max.Pressure(Pa) | Input Power(W) | Speed(rpm) | Noise(db) | |
|---|---|---|---|---|---|---|---|---|
![]() R3G630-PC08-03 | ebm-papst 400V EC Centrifugal Fan for Data Centers The ebm-papst R3G630-PC08-03 is a high-performance EC centrifugal fanfrom the renowned RadiPac series, engineered specifically formission-critical data center cooling applications. |
- | - | - | - | - | - | - | |
![]() 9GA0912P4S03 | Sanyo Denki 12VDC 2.4W DC Axial Fan for UPS, server and telecom equipment cooling The 9GA0912P4S03 is a Sanyo Denki 12 VDC, 92 × 92 × 25 mm DC axial fan for servers, UPS systems, and telecom equipment. Long-life series construction is the main characteristic stated in the supplied reference. The recorded operating point should guide duty-point matching. Confirm control inputs against the complete ordering code. |
12 | 92*92*25 | 100 | 60.6 | 2.4 | 3800 | 35 | |
![]() GR31I-ZID.DC.CR 116889/A01 | ZIEHL-ABEGG 3~380-480VAC 2400W EC Centrifugal Fan for data center cooling GR31I-ZID.DC.CR 116889/A01 is a 3~380-480 VAC centrifugal fan for data centers. Its main supplied feature is 2400 W input power for the listed electrical version. It also lists a 310 mm size specified in the upload data. Review performance curve for spares planning. Check the exact variant before ordering. |
- | - | - | - | - | - | - | |
![]() GR25I-6ID.BD.CR 116883/A01 | ZIEHL-ABEGG 1~200-277VAC 780W EC Centrifugal Fan for data center cooling GR25I-6ID.BD.CR 116883/A01 is a 1~200-277 VAC centrifugal fan for data centers. Its main supplied feature is 1190 Pa maximum pressure stated for this model. It also lists a 250 mm size specified in the upload data. Review maintenance access for spares planning. Check the exact variant before ordering. |
- | - | - | - | - | - | - | |
![]() GR56I-ZID.GG.CR 116907/A01 | ZIEHL-ABEGG 3~380-480VAC 3400W EC Centrifugal Fan for data center cooling GR56I-ZID.GG.CR 116907/A01 is a 3~380-480 VAC centrifugal fan for data centers. Its main supplied feature is a backward-curved impeller configuration. It also lists a 560 mm size specified in the upload data. Review fan selection for spares planning. Use the complete model code and supplied parameters when confirming the final installation. |
- | - | - | - | - | - | - | |
![]() GR31I-6IK.BD.CR 116887/A01 | ZIEHL-ABEGG 1~220-277VAC EC Centrifugal Fan for data center cooling Specified at 1~220-277 VAC, GR31I-6IK.BD.CR 116887/A01 is a centrifugal fan developed around data centers. Its representative supplied feature is a 310 mm size specified in the upload data. Selection focus: equipment interface during cabinet planning. Use the complete model code and supplied parameters when confirming the final installation. |
- | - | - | - | - | - | - | |
![]() GTW091PBU29E-V007 | Delta 3~380-480VAC 2153/4000W 910mm EC Axial Fan for Data Center AHU Delta GTW091PBU29E-V007 is a 3~380-480 VAC EC axial fan for data-center air-handling units. Its supplied data lists 32,843 m³/h maximum airflow, 504 Pa pressure, 1,260 rpm, and 2,153/4,000 W power. It supports 0-10 V, PWM, and RS485 control, with IP55 protection and maintenance-free ball bearings. |
3~ 380-480 | 910 | 32843 | 504 | 2153/4000 | 1260 | 86.3 | |
![]() 109R0624G401 | Sanyo Denki 24VDC 3.12W DC Axial Fan for UPS, server and telecom equipment cooling Sanyo Denki configures 109R0624G401 for servers, UPS systems, and telecom equipment as a 24 VDC DC axial fan with 60 × 60 × 25 mm dimensions. The 46.2 m³/h airflow figure supports its stated equipment-cooling role. The recorded thermal-duty record should guide mounting verification. Verify the exact bearing and signal options in the datasheet. |
24 | 60*60*25 | 46.2 | 87.3 | 3.12 | 5600 | 39 | |
![]() 9A0624H4D08 | Sanyo Denki 24VDC DC Axial Fan for UPS, server and telecom equipment cooling For servers, UPS systems, and telecom equipment, 9A0624H4D08 combines 24 VDC operation with a 60 × 60 × 25 mm DC axial fan design. High airflow is highlighted together with a high-static-pressure design. The 60 × 60 × 25 mm format is the primary stated selection detail. Check spares strategy planning ventilation capacity. |
24 | 60*60*25 | - | - | - | - | - | |
![]() 109P0424H302 | Sanyo Denki 24VDC DC Axial Fan for UPS, server and telecom equipment cooling The 40 × 40 × 28 mm Sanyo Denki 109P0424H302 brings 24 VDC DC axial fan cooling to servers, UPS systems, and telecom equipment. Series focus: high airflow and pressure. Treat the thermal-duty record as a primary input to power-budget planning. Validate mounting and wiring from the model drawing. Focus: spares strategy planning equipment fit. |
24 | 40*40*28 | - | - | - | 8700 | 37 | |
![]() 9CRA0612P6K001 | Sanyo Denki 12VDC 37.2W Counter-Rotating DC Axial Fan for data center and telecom cooling Within servers, UPS systems, and telecom equipment, Sanyo Denki 9CRA0612P6K001 operates as a 60 × 60 × 56 mm DC axial fan at 12 VDC. Series options require suffix verification. The supplied row lists 73 dB as an important acoustic selection value. Focus: spares strategy planning suffix definition. |
12 | 60*60*56 mm | 136.8 | 1130 | 37.2 | 18300 | 73 | |
![]() 9HV0824P1G003 | Sanyo Denki 24VDC 40.8W DC Axial Fan for AI servers and high-density equipment cooling Sanyo Denki configures 9HV0824P1G003 for AI servers and high-density electronics as a 24 VDC DC axial fan with 80 × 80 × 38 mm dimensions. The supplied row lists 69 dB as an important acoustic selection value. For enclosure sizing, start with the supplied ventilation capacity. Use the latest specification for frequency and tolerance limits. |
24 | 80*80*38 mm | 222 | 1000 | 40.8 | 14900 | 69 | |
![]() 9A0824S401 | Sanyo Denki 24VDC 2.4W DC Axial Fan for UPS, server and telecom equipment cooling Within servers, UPS systems, and telecom equipment, 9A0824S401 provides a 80 × 80 × 25 mm, 24 VDC DC axial fan configuration. High airflow is highlighted together with a high-static-pressure design. 48.1 Pa maximum pressure is the most distinctive duty-point parameter. Check spares strategy planning performance curve. |
24 | 80*80*25 | 71.4 | 48.1 | 2.4 | 3400 | 34 | |
![]() 9A0812H401 | Sanyo Denki 12VDC 1.56W DC Axial Fan for UPS, server and telecom equipment cooling Within servers, UPS systems, and telecom equipment, 9A0812H401 provides a 80 × 80 × 25 mm, 12 VDC DC axial fan configuration. High airflow is highlighted together with a high-static-pressure design. A listed input of 1.56 W is the notable efficiency-related parameter. Check spares strategy planning mounting size. Focus: spares strategy planning. |
12 | 80*80*25 | 61.2 | 35.4 | 1.56 | 2900 | 29 | |
![]() 109P0624S702 | Sanyo Denki 24VDC 1.92W DC Axial Fan for UPS, server and telecom equipment cooling For servers, UPS systems, and telecom equipment, 109P0624S702 combines 24 VDC operation with a 60 × 60 × 15 mm DC axial fan design. High airflow is highlighted together with a high-static-pressure design. The 28.4 m³/h airflow figure supports its stated equipment-cooling role. Check spares strategy planning supply requirement. |
24 | 60*60*15 | 28.4 | 58.8 | 1.92 | 5000 | 36 | |
![]() 109P0612H602 | Sanyo Denki 12VDC 1.56W DC Axial Fan for UPS, server and telecom equipment cooling A 60 × 60 × 20 mm frame and 12 VDC rating define 109P0612H602, a DC axial fan for servers, UPS systems, and telecom equipment. Series focus: high airflow and pressure. 31.8 Pa maximum pressure is the most distinctive duty-point parameter. Check spares strategy planning static-pressure entry. Focus: spares strategy planning static-pressure entry. |
12 | 60*60*20 | 24.8 | 31.8 | 1.56 | 4200 | 31 | |
![]() 9S1224M4011 | Sanyo Denki 24VDC 1.44W DC Axial Fan for UPS, server and telecom equipment cooling Equipment designers serving servers, UPS systems, and telecom equipment can evaluate Sanyo Denki 9S1224M4011, a DC axial fan rated at 24 VDC and sized 120 × 120 × 25 mm. Its 1850 rpm rating defines a lower-speed operating point. The recorded duty-point values should guide spares assessment. Match the exact part number before approving a substitute. |
24 | 120*120*25 mm | 99.6 | 22.7 | 1.44 | 1850 | 24 | |
![]() 9GA0812P1G61 | Sanyo Denki 12VDC 14.4W DC Axial Fan for UPS, server and telecom equipment cooling A 80 × 80 × 38 mm frame and 12 VDC rating define 9GA0812P1G61, a DC axial fan for servers, UPS systems, and telecom equipment. Long-life series construction is the main characteristic stated in the supplied reference. 480 Pa maximum pressure is the most distinctive duty-point parameter. Selection focus: spares strategy planning sound level. |
12 | 80*80*38 mm | 171 | 480 | 14.4 | 10500 | 60 | |
![]() 9GA0924P4J03 | Sanyo Denki 24VDC 4.8W DC Axial Fan for UPS, server and telecom equipment cooling Sanyo Denki 9GA0924P4J03 combines a 92 × 92 × 25 mm DC axial fan platform with a 24 VDC rating for servers, UPS systems, and telecom equipment. Long-life series construction is the main characteristic stated in the supplied reference. Its listed airflow of 132.09 m³/h is the standout performance value. Focus: spares strategy planning. |
24 | 92*92*25 | 132.09 | 104.6 | 4.8 | 5000 | 43 | |
![]() 9GA0824P4G001 | Sanyo Denki 24VDC 5.04W DC Axial Fan for UPS, server and telecom equipment cooling For thermal management in servers, UPS systems, and telecom equipment, the 9GA0824P4G001 provides a 24 VDC DC axial fan configuration measuring 80 × 80 × 25 mm. 6800 rpm is the model's most prominent operating value. The recorded power demand should guide replacement evaluation. Validate mounting and wiring from the model drawing. |
24 | 80*80*25 | 115 | 150 | 5.04 | 6800 | 45 |
The most reliable way to specify data Center Cooling is to work from the system, not from the catalog. Measure or calculate the airflow and pressure demand first, add the dimensional limits of the mounting position, and only then shortlist series whose curves cover your operating point with margin.
Electrical matching is the next gate. Confirm the supply voltage — 12 V, 24 V or 48 V DC for compact electronics cooling, 115 V or 230 V AC for equipment and panel cooling — and decide whether you need speed control. EC models accept PWM or 0-10 V signals and report speed through a tachometer output, which makes them the default choice for variable-airflow systems, while AC units remain a cost-effective answer for fixed-speed duty.
Then filter by environment. High ambient temperature, dust or moisture loads dictate the IP rating and bearing choice — ball bearings keep airflow and noise stable over years, while sleeve bearings suit light-duty horizontal mounting. Regulatory needs such as UL, CE and RoHS recognition should be confirmed before the shortlist goes to purchasing, together with a maximum allowed sound pressure level in dBA.
End the process by checking supply, not just specification: confirm current stock, the lead time for follow-up quantities, and obtain datasheets and dimension drawings so the mechanical interface is verified before the PO. Send us your airflow and pressure requirements and our engineers will confirm the best-matched series — 816 products are available in this category today.
The daily work of our sales engineers is built around data Center Cooling used in data center cooling, refrigeration and cold chain projects, building ventilation, telecom base stations, medical devices and industrial control cabinets — environments where a stopped fan is a stopped business process. That daily exposure to real installations is exactly what we bring back into every selection: not just reading curves, but knowing which models survive dust, heat, continuous duty and restricted service access.
A typical case: an equipment builder needed to replace an aging AC fan inside a control cabinet that could not be taken offline for more than an hour. By cross-referencing the frame dimensions, voltage and airflow curve, we supplied a current-series drop-in replacement with a matching tachometer signal, and the swap was completed during a scheduled maintenance window.
Refrigeration and cold chain customers bring us another pattern: the failed condenser fan is unavailable for weeks. Comparing diameter, speed, bearings and IP rating, we supply a functionally equivalent unit from stock so the system returns to duty the same week — the reason many service companies keep our contact number on file.
From one-piece emergency replacements to volume supply for equipment manufacturers, every enquiry is handled by the same rule: verify the parameters first, then quote — so what arrives on site is the fan the project actually needs.
Datasheets, performance curves, dimension drawings and certification files (UL, CE, RoHS where applicable) are available on request before you buy — we believe a purchase order should follow a verified selection, not replace it. For project tenders we can also provide product comparison tables that put the candidate models side by side on the parameters you care about.
Common series and mainstream voltage versions are normally in stock and can ship within a few working days; specialized or customized variants are produced to order and typically require additional production time. Send us the exact model or the required parameters and we will confirm stock, unit price and the earliest shipment date in one reply Currently 816 products in this category are listed online.
Yes. Replacement supply is one of our core services: we cross-reference the mounting dimensions, voltage, speed and performance curve of your installed unit and propose the closest current-series equivalent. Where the frame or connector differs slightly, we state the difference clearly before you order, so the replacement installs without surprises.
Bag
Bag packaging indicates that a specified quantity of product is packaged by the manufacturer in a bag, sealed pouch, or similar container and sold as a unit without repackaging. It is also used to describe kits/assortments where components are packaged in separate bags according to part number or parametric value, rather than in a compartmentalized box or similar rigid container.