1-20 21-40 41-60 61-80 81-100 101-120 121-140 141-160 161-180 181-200 201-220 221-240 241-260 261-280 281-300 301-320 321-340 341-360 361-380 381-400 401-420 421-440 441-460 461-480 481-500 501-520 521-540 541-560 561-580 581-600 601-620 621-640 641-660 661-680 681-700 701-720 721-740 741-760 761-780 781-800 801-816
of 816
Download Table
Mfr Part # Rated Voltage(V) Size(mm) Max.Air Flow(m³/h) Max.Pressure(Pa) Input Power(W) Speed(rpm) Noise(db)
109R0612M4D01 | Sanyo Denki 12VDC DC Axial Fan for UPS, server and telecom equipment cooling

The 109R0612M4D01 is a Sanyo Denki 12 VDC, 60 × 60 × 25 mm DC axial fan for servers, UPS systems, and telecom equipment. Series focus: high airflow and pressure. Treat the frame geometry as a primary input to mounting verification. Verify the exact bearing and signal options in the datasheet. Focus: service access planning power demand.

12 60*60*25 21.4 19.6 - 2600 20
109R1212H101 | Sanyo Denki 12VDC DC Axial Fan for UPS, server and telecom equipment cooling

The 120 × 120 × 38 mm Sanyo Denki 109R1212H101 brings 12 VDC DC axial fan cooling to servers, UPS systems, and telecom equipment. High airflow is highlighted together with a high-static-pressure design. The recorded system interface should guide power-budget planning. Review connector, alarm, and sensor options separately.

12 120*120*38 - - - - -
9G0648P4S001 | Sanyo Denki 48VDC 8.64W DC Axial Fan for UPS, server and telecom equipment cooling

Sanyo Denki 9G0648P4S001 is a 48 VDC DC axial fan in a 60×60×25 mm format for servers, UPS systems, and telecom equipment. High airflow is highlighted together with a high-static-pressure design. 11000 rpm is the model's most prominent operating value. Check service access planning cooling output. Focus: service access planning cooling output.

48 60×60×25 84 305 8.64 11000 53
109E5724K502 | Sanyo Denki 24VDC 31.2W DC Axial Fan for UPS, server and telecom equipment cooling

A 172 × 150 × 51 mm frame and 24 VDC rating define 109E5724K502, a DC axial fan for servers, UPS systems, and telecom equipment. Series focus: high airflow and pressure. Its listed airflow of 504 m³/h is the standout performance value. Check service access planning operating point. Focus: service access planning operating point.

24 172*150*51 504 243 31.2 4100 60
109E1724M502 | Sanyo Denki 24VDC 4.8W DC Axial Fan for UPS, server and telecom equipment cooling

Sanyo Denki 109E1724M502 is a 24 VDC DC axial fan in a size not stated format for servers, UPS systems, and telecom equipment. Series focus: high airflow and pressure. Its 2000 rpm rating defines a lower-speed operating point. Check service access planning pressure capability. Focus: service access planning pressure capability.

24 - 248.4 67.6 4.8 2000 36
9G1248P1G051 | Sanyo Denki 48VDC DC Axial Fan for UPS, server and telecom equipment cooling

The 48 VDC Sanyo Denki 9G1248P1G051 is a DC axial fan sized 120 × 120 × 38 mm for servers, UPS systems, and telecom equipment. Series focus: high airflow and pressure. The 120 × 120 × 38 mm format is the primary stated selection detail. Check service access planning electrical load. Focus: service access planning electrical load.

48 120*120*38 - - - - -
9G1224G4D011 | Sanyo Denki 24VDC 11.28W DC Axial Fan for UPS, server and telecom equipment cooling

Sanyo Denki 9G1224G4D011 is a 24 VDC DC axial fan in a 119 × 119 × 25 mm format for servers, UPS systems, and telecom equipment. High airflow is highlighted together with a high-static-pressure design. Its listed airflow of 218.4 m³/h is the standout performance value. Check lifecycle requirement review system interface.

24 119*119*25 218.4 120 11.28 4100 51
9HV1248P1G013 | Sanyo Denki 48VDC DC Axial Fan for AI servers and high-density equipment cooling

The 9HV1248P1G013 is a Sanyo Denki 48 VDC, 120 × 120 × 38 mm DC axial fan for AI servers and high-density electronics. Ultra-high static-pressure capability is the representative series characteristic. The recorded frame geometry should guide thermal validation. Treat bearing and life data as suffix-specific. Focus: lifecycle requirement review.

48 120*120*38 - - - - -
109E4724H4D01 | Sanyo Denki 24VDC 24W DC Axial Fan for UPS, server and telecom equipment cooling

For servers, UPS systems, and telecom equipment, 109E4724H4D01 combines 24 VDC operation with a 172 × 147 × 25.4 mm DC axial fan design. Series focus: high airflow and pressure. Its listed airflow of 379.8 m³/h is the standout performance value. Check lifecycle requirement review installation footprint. Focus: lifecycle requirement review.

24 172*147*25.4 379.8 135 24 3400 57
109P0624H738 | Sanyo Denki 24VDC DC Axial Fan for UPS, server and telecom equipment cooling

For thermal management in servers, UPS systems, and telecom equipment, the 109P0624H738 provides a 24 VDC DC axial fan configuration measuring 60 × 60 × 15 mm. The 60 × 60 × 15 mm format is the primary stated selection detail. The recorded motor input should guide compatibility checking. Confirm environmental protection for the ordered version.

24 60*60*15 - - - - -
9A0912H4021 | Sanyo Denki 12VDC 2.52W DC Axial Fan for UPS, server and telecom equipment cooling

Sanyo Denki configures 9A0912H4021 for servers, UPS systems, and telecom equipment as a 12 VDC DC axial fan with 92 × 92 × 25 mm dimensions. 44.1 Pa maximum pressure is the most distinctive duty-point parameter. During cooling-margin review, compare the model's mounting size. Use the latest specification for frequency and tolerance limits.

12 92*92*25 85.8 44.1 2.52 3150 33
109R0612S4D01 | Sanyo Denki 12VDC 2.04W DC Axial Fan for UPS, server and telecom equipment cooling

Sanyo Denki 109R0612S4D01 combines a 60 × 60 × 25 mm DC axial fan platform with a 12 VDC rating for servers, UPS systems, and telecom equipment. The supplied reference emphasizes high static pressure and high airflow. A listed input of 2.04 W is the notable efficiency-related parameter. Selection focus: lifecycle requirement review motor input.

12 60*60*25 38.6 56.8 2.04 4600 33
109P0412K3013 | Sanyo Denki 12VDC 6.6W DC Axial Fan for UPS, server and telecom equipment cooling

The 40 × 40 × 28 mm Sanyo Denki 109P0412K3013 brings 12 VDC DC axial fan cooling to servers, UPS systems, and telecom equipment. Series focus: high airflow and pressure. For enclosure sizing, start with the supplied equipment fit. Use current model documentation to validate protection choices. Focus: lifecycle requirement review equipment fit.

12 40*40*28 34.9 340 6.6 15500 50
109R0812F4021 | Sanyo Denki 12VDC 1.32W DC Axial Fan for UPS, server and telecom equipment cooling

Sanyo Denki 109R0812F4021 combines a 80 × 80 × 25 mm DC axial fan platform with a 12 VDC rating for servers, UPS systems, and telecom equipment. High airflow is highlighted together with a high-static-pressure design. A listed noise figure of 26 dB is the key differentiating parameter. Focus: lifecycle requirement review suffix definition.

12 80*80*25 54.6 28.4 1.32 2600 26
9G0924G102 | Sanyo Denki 24VDC 13.2W DC Axial Fan for UPS, server and telecom equipment cooling

The 9G0924G102 is a Sanyo Denki 24 VDC, 92 × 92 × 38 mm DC axial fan for servers, UPS systems, and telecom equipment. Series focus: high airflow and pressure. For fan selection, start with the supplied equipment fit. Confirm control inputs against the complete ordering code. Focus: lifecycle requirement review catalog specification.

24 92*92*38 184.8 149.9 13.2 5000 50
9GA0824P1S61 | Sanyo Denki 24VDC 11.28W DC Axial Fan for UPS, server and telecom equipment cooling

For thermal management in servers, UPS systems, and telecom equipment, the 9GA0824P1S61 provides a 24 VDC DC axial fan configuration measuring 80 × 80 × 38 mm. 480 Pa maximum pressure is the most distinctive duty-point parameter. Base cooling-margin review on the stated electrical load. Confirm environmental protection for the ordered version.

24 80*80*38 156 480 11.28 9550 59
9GA0924P1H01 | Sanyo Denki 24VDC 26.4W DC Axial Fan for UPS, server and telecom equipment cooling

The 92 × 92 × 38 mm Sanyo Denki 9GA0924P1H01 brings 24 VDC DC axial fan cooling to servers, UPS systems, and telecom equipment. Long-life series construction is the main characteristic stated in the supplied reference. The recorded mounting size should guide system-resistance review. Review connector, alarm, and sensor options separately.

24 92*92*38 240 500 26.4 9700 63
9S0924M4D01 | Sanyo Denki 24VDC 1.68W DC Axial Fan for UPS, server and telecom equipment cooling

9S0924M4D01 addresses servers, UPS systems, and telecom equipment through a 24 VDC DC axial fan platform measuring 92 × 92 × 25 mm. Series focus: high airflow and pressure. A listed noise figure of 22 dB is the key differentiating parameter. Check lifecycle requirement review supply requirement. Focus: lifecycle requirement review.

24 92*92*25 63.6 21.7 1.68 2250 22
109L1224H105 | Sanyo Denki 24VDC DC Axial Fan for UPS, server and telecom equipment cooling

The 24 VDC Sanyo Denki 109L1224H105 is a DC axial fan sized 120 × 120 × 38 mm for servers, UPS systems, and telecom equipment. Series focus: high airflow and pressure. The 120 × 120 × 38 mm format is the primary stated selection detail. Check lifecycle requirement review static-pressure entry. Focus: lifecycle requirement review.

24 120*120*38 - - - - -
9GA0612P1J031 | Sanyo Denki 12VDC 18W DC Axial Fan for UPS, server and telecom equipment cooling

The 60×60×38 mm Sanyo Denki 9GA0612P1J031 brings 12 VDC DC axial fan cooling to servers, UPS systems, and telecom equipment. Long-life series construction is the main characteristic stated in the supplied reference. Treat the installation footprint as a primary input to power-budget planning. Review connector, alarm, and sensor options separately.

12 60×60×38 105 820 18 17500 63
Showing
181-200
1-20 21-40 41-60 61-80 81-100 101-120 121-140 141-160 161-180 181-200 201-220 221-240 241-260 261-280 281-300 301-320 321-340 341-360 361-380 381-400 401-420 421-440 441-460 461-480 481-500 501-520 521-540 541-560 561-580 581-600 601-620 621-640 641-660 661-680 681-700 701-720 721-740 741-760 761-780 781-800 801-816
of 816
1 2 ... 7 8 9 10 11 12 13 ... 40 41
GO page

About Data Center Cooling

Data center cooling fans are specialized ventilation components engineered to maintain the precise temperature and humidity requirements of modern computing infrastructure. As data centers grow in density with higher TDP processors and accelerated adoption of AI and HPC workloads, cooling fan performance and energy efficiency have become critical operational concerns. Data center cooling fans serve three primary architectural roles: server-level fans (120mm DC axial fans mounted in server chassis for direct component cooling), rack-level cooling (inline or roof-mounted EC fans for hot-aisle containment systems), and facility-level HVAC fans (air handling units with EC backward curved centrifugal blowers for building-wide circulation). Key design requirements for data center fans include: reliability (MTBF typically exceeding 100,000 hours), quiet operation (dBA levels for occupied spaces), EC technology for energy efficiency and variable speed, PWM or Modbus control for intelligent thermal management, and hot-swap capability for critical systems. Leading manufacturers include ebm-papst, ZIEHL-ABEGG, Rosenberg, Sanyo Denki, and SUNON. Hengrui supplies data center cooling fans with cross-reference tools, competitive pricing, and engineering consultation.

How to Select the Right Data Center Cooling

The most reliable way to specify data Center Cooling is to work from the system, not from the catalog. Measure or calculate the airflow and pressure demand first, add the dimensional limits of the mounting position, and only then shortlist series whose curves cover your operating point with margin.

Electrical matching is the next gate. Confirm the supply voltage — 12 V, 24 V or 48 V DC for compact electronics cooling, 115 V or 230 V AC for equipment and panel cooling — and decide whether you need speed control. EC models accept PWM or 0-10 V signals and report speed through a tachometer output, which makes them the default choice for variable-airflow systems, while AC units remain a cost-effective answer for fixed-speed duty.

Then filter by environment. High ambient temperature, dust or moisture loads dictate the IP rating and bearing choice — ball bearings keep airflow and noise stable over years, while sleeve bearings suit light-duty horizontal mounting. Regulatory needs such as UL, CE and RoHS recognition should be confirmed before the shortlist goes to purchasing, together with a maximum allowed sound pressure level in dBA.

End the process by checking supply, not just specification: confirm current stock, the lead time for follow-up quantities, and obtain datasheets and dimension drawings so the mechanical interface is verified before the PO. Send us your airflow and pressure requirements and our engineers will confirm the best-matched series — 816 products are available in this category today.

Typical Applications and Use Cases for Data Center Cooling

The daily work of our sales engineers is built around data Center Cooling used in data center cooling, refrigeration and cold chain projects, building ventilation, telecom base stations, medical devices and industrial control cabinets — environments where a stopped fan is a stopped business process. That daily exposure to real installations is exactly what we bring back into every selection: not just reading curves, but knowing which models survive dust, heat, continuous duty and restricted service access.

A typical case: an equipment builder needed to replace an aging AC fan inside a control cabinet that could not be taken offline for more than an hour. By cross-referencing the frame dimensions, voltage and airflow curve, we supplied a current-series drop-in replacement with a matching tachometer signal, and the swap was completed during a scheduled maintenance window.

Refrigeration and cold chain customers bring us another pattern: the failed condenser fan is unavailable for weeks. Comparing diameter, speed, bearings and IP rating, we supply a functionally equivalent unit from stock so the system returns to duty the same week — the reason many service companies keep our contact number on file.

From one-piece emergency replacements to volume supply for equipment manufacturers, every enquiry is handled by the same rule: verify the parameters first, then quote — so what arrives on site is the fan the project actually needs.

Frequently Asked Questions About Buying Data Center Cooling

What technical documentation do you provide before purchase?

Datasheets, performance curves, dimension drawings and certification files (UL, CE, RoHS where applicable) are available on request before you buy — we believe a purchase order should follow a verified selection, not replace it. For project tenders we can also provide product comparison tables that put the candidate models side by side on the parameters you care about.

Do you have data Center Cooling in stock and how fast can you deliver?

Common series and mainstream voltage versions are normally in stock and can ship within a few working days; specialized or customized variants are produced to order and typically require additional production time. Send us the exact model or the required parameters and we will confirm stock, unit price and the earliest shipment date in one reply Currently 816 products in this category are listed online.

Can you replace my existing data Center Cooling from another supplier or a discontinued model?

Yes. Replacement supply is one of our core services: we cross-reference the mounting dimensions, voltage, speed and performance curve of your installed unit and propose the closest current-series equivalent. Where the frame or connector differs slightly, we state the difference clearly before you order, so the replacement installs without surprises.

Bag

Bag packaging indicates that a specified quantity of product is packaged by the manufacturer in a bag, sealed pouch, or similar container and sold as a unit without repackaging. It is also used to describe kits/assortments where components are packaged in separate bags according to part number or parametric value, rather than in a compartmentalized box or similar rigid container.