Get Quote
Home > Products > By type > Axial Fans > 9GA0612P1J031 | Sanyo Denki 12VDC 18W DC Axial Fan for UPS, server and telecom equipment cooling

9GA0612P1J031 Sanyo Axial Fan

Brand :
Sanyo
Model:
9GA0612P1J031 | Sanyo Denki 12VDC 18W DC Axial Fan for UPS, server and telecom equipment cooling
Type:
Axial Fans
Industry:
Data Center Cooling
Description:

The 60×60×38 mm Sanyo Denki 9GA0612P1J031 brings 12 VDC DC axial fan cooling to servers, UPS systems, and telecom equipment. Long-life series construction is the main characteristic stated in the supplied reference. Treat the installation footprint as a primary input to power-budget planning. Review connector, alarm, and sensor options separately.

Datasheet:
9GA0612P1J031 | Sanyo Denki 12VDC 18W DC Axial Fan for UPS, server and telecom equipment cooling Datasheet (Pdf)

Product Features

Rated Voltage(V)12
Size(mm)60×60×38
Max.Air Flow(m³/h)105
Max.Pressure(Pa)820
Input Power(W)18
Speed(rpm)17500
Noise(db)63

Product Features

Stable San Ace Fan

The SANYO DENKI 9GA0612P1J031 is a DC axial fan developed for servers, storage systems and ICT equipment. Its directed airflow helps remove heat from densely arranged components and supports predictable equipment temperatures.

Its 105 m3/h maximum airflow supports rapid air exchange, while 820 Pa pressure capability helps overcome resistance within the finished equipment. Buyers should confirm the complete suffix, connector, sensor output and control option before ordering. Engineers should validate the operating point with the actual grille and filter.

Confirm inlet clearance around nearby cables. It also creates a clearer thermal approval record. Confirm the final fan curve in the assembled equipment.

Application Industry

Frequently Asked Questions

What should be checked if 9GA0612P1J031 stops?

Verify supply, connector, obstructions, impeller movement, and alarm or protection status using the model-specific troubleshooting data.

Is 9GA0612P1J031 easy to install and maintain?

Confirm connector and mounting details, keep the airflow path clear, and isolate power before cleaning or service.

How should 9GA0612P1J031 be matched to an enclosure?

Check its 60×60×38 mm size, 105 m³/h airflow, 820 Pa pressure, mounting points, airflow direction, and system resistance.

What certifications apply to 9GA0612P1J031?

The workbook marks it RoHS compliant. Confirm model-specific UL, CSA, TÜV, or other required approvals from official documentation.

Which application details matter most for 9GA0612P1J031?

Review ambient temperature, airflow restriction, contamination exposure, noise limit, mounting orientation, and maintenance access.

What maintenance does 9GA0612P1J031 require?

Inspect dust buildup, airflow blockage, abnormal noise, mounting security, and wiring condition; disconnect power before service.