Mfr Part # Rated Voltage(V) Size(mm) Max.Air Flow(m³/h) Max.Pressure(Pa) Input Power(W) Speed(rpm) Noise(db)
109BC24GC7-1 | Sanyo Denki 24VDC 1.68W DC Centrifugal Blower for medical equipment cooling

Sanyo Denki 109BC24GC7-1 combines a 52 × 52 × 15 mm DC blower platform with a 24 VDC rating for medical equipment cooling. The series cooling function is confirmed; suffix-specific options require datasheet verification. The 7.5 m³/h airflow figure supports its stated equipment-cooling role. Focus: spares strategy planning cooling specification.

24 52*52*15 mm 7.5 215 1.68 6200 43
9BMB24P2H01 | Sanyo Denki 24VDC 13.2W DC Centrifugal Blower for medical equipment cooling

Sanyo Denki 9BMB24P2H01 is a 24 VDC DC blower in a 97 × 97 × 33 mm format for medical equipment cooling. Series options require suffix verification. 490 Pa maximum pressure is the most distinctive duty-point parameter. Check spares strategy planning installation footprint. Focus: spares strategy planning installation footprint.

24 97*97*33 mm 66.6 490 13.2 4850 57
9BD12SC6-1 | Sanyo Denki 12VDC 3.36W DC Centrifugal Blower for medical equipment cooling

The 76 × 76 × 20 mm Sanyo Denki 9BD12SC6-1 brings 12 VDC DC blower cooling to medical equipment cooling. Series options require suffix verification. Use the documented static-pressure entry when planning wiring review. Verify the exact bearing and signal options in the datasheet. Focus: spares strategy planning rated dataset.

12 76*76*20 mm 17.4 300 3.36 4500 43
9BMB12P2G01 | Sanyo Denki 12VDC 21.6W DC Centrifugal Blower for medical equipment cooling

For medical equipment cooling, 9BMB12P2G01 combines 12 VDC operation with a 97 × 97 × 33 mm DC blower design. Series options require suffix verification. 760 Pa maximum pressure is the most distinctive duty-point parameter. Check selection criteria review frame geometry. Focus: selection criteria review frame geometry.

12 97*97*33 mm 80.4 760 21.6 5750 61
9BMB24P2KD03 | Sanyo Denki 24VDC 97x33mm DC Centrifugal Blower for medical equipment cooling

For thermal management in medical equipment cooling, the 9BMB24P2KD03 provides a 24 VDC DC blower configuration measuring 97 × 33 mm. The 97 × 33 mm format is the primary stated selection detail. Use the documented cooling output when planning enclosure sizing. Check the full suffix before confirming connector details.

24 97*33 - - - - -
9BMB24P2K27 | Sanyo Denki 24VDC 97x33mm DC Centrifugal Blower for medical equipment cooling

A 97 × 33 mm frame and 24 VDC rating define 9BMB24P2K27, a DC blower for medical equipment cooling. Series options require suffix verification. The 97 × 33 mm format is the primary stated selection detail. Check cooling margin validation mounting size. Focus: cooling margin validation mounting size.

24 97*33 - - - - -
9GP1224P1G001 | Sanyo Denki 24VDC 38.4W San Ace DC Axial Fan for medical equipment cooling

Sanyo Denki 9GP1224P1G001 is a 24 VDC DC axial fan in a 120 × 120 × 38 mm format for electronic equipment cooling. Control and monitoring availability is suffix-specific according to the supplied reference. 38.4 W input is the defining electrical-load figure. Check wiring scheme review suffix definition. Focus: wiring scheme review.

24 120*120*38 420 370 38.4 6550 62
W1G200-HH01-52 | ebm-papst 48V 55W EC Axial Fan for Medical Equipment Cooling

Adapted for Medical Equipment Cooling, the ebm-papst W1G200-HH01-52 is a 48 V EC axial fan, distinguished by 200 mm dimensions for installation planning. It gives project engineers a selection cue.

48 200 - 120 55 2950 -
R4E355-AK05-05 | ebm-papst 230V 180W Centrifugal Fan for Medical

Built for Medical, the ebm-papst R4E355-AK05-05 is a 230 V AC backward-curved centrifugal fan, with a focus on a documented speed of 1,400 rpm. This enables specification-led selection.

230 355 2695 300 180 1400 -
R3G400-RJ75-01 | ebm-papst 3~380-480V 1320W Centrifugal Fan for Medical

Developed for Medical, the ebm-papst R3G400-RJ75-01 is a 380-480V EC backward-curved centrifugal fan, distinguished by a listed airflow of 4,090 m³/h. The rating clarifies its operating profile.

3`380-480 400 4090 - 1320 2060 -
R3G225-RD05-03 | ebm-papst 1~ 200-277V 82W Centrifugal Fan for Medical

Developed for Medical, the ebm-papst R3G225-RD05-03 is a 200-277V EC backward-curved centrifugal fan, defined by a listed acoustic value of 52 dB. The data helps compare K-series variants.

1~200-277 225 585 240 82 2200 52
R3G220-RC05-03 | ebm-papst 1~ 200-277V 85W Centrifugal Fan for Medical

Intended for Medical, the ebm-papst R3G220-RC05-03 is a 200-277V EC backward-curved centrifugal fan, defined by 220 mm dimensions for installation planning. The data helps compare K-series variants.

1~200-277 220 - - 85 2580 -
R2E225-RA92-09 | ebm-papst 230V 155W Centrifugal Fan for Medical

Designed for Medical, the ebm-papst R2E225-RA92-09 is a 230 V AC forward-curved centrifugal fan, whose supplied data highlights a listed acoustic value of 58 dB. The rating clarifies its operating profile.

230 225 705 425 155 2560 58
230 190 540 240 52 2352 58
230 190 570 240 61 2500 62
230 180 440 220 60 2550 64
QG030-353/14 | ebm-papst 24V 9.6W DC Tangential Blower for Medical

Suited to Medical, the ebm-papst QG030-353/14 is a 24 V DC Tangential Blower, with a documented 9.6 W input rating. The rating aids system-fit checks. Its supplied parameters support professional equipment integration.

24 - 155 - 9.6 3850 -
G3G225-AD29-71 | ebm-papst 230V 545W EC Centrifugal Blower for Pharmaceutical Equipment

Designed around pharmaceutical equipment, G3G225-AD29-71 uses a 230 V EC centrifugal blower platform. Among the supplied ratings, a listed 58 dB noise value with a 545 W input rating clearly differentiates this variant.

230 225 1655 600 545 1815 58
G3G180-AD43-71 | ebm-papst 230V 510W EC Centrifugal Blower for Medical Ventilation

G3G180-AD43-71 combines 230 V operation with a EC centrifugal blower format for medical ventilation. The supplied specifications highlight a listed 56 dB noise value with 0-10 V/PWM speed control.

230 180 1305 700 510 2450 56
G2E140-NS38-01 | ebm-papst 230V 105W AC Centrifugal Blower for Emergency Vehicles

A 230 V AC centrifugal blower for emergency vehicles, G2E140-NS38-01 has a clearly defined selection profile. The supplied specifications highlight thermal-overload protection with a 140 mm frame.

230 140 390 300 105 1800 -
Showing
1-20
1-20 21-23
of 23
1 2
GO page

About Medical Equipment

Medical Equipment category features specialized industrial fans designed for healthcare and medical device cooling applications. This curated collection includes ebm-papst AC centrifugal blowers engineered to meet the strict reliability and hygiene standards required in clinical environments.

The product range covers 230V models spanning 150W to 355W power output, with airflow capacities suitable for CT scanner cooling, ventilator heat dissipation, infusion pump temperature regulation, and laboratory equipment thermal management. All fans listed here maintain consistent rotational performance under demanding hospital conditions and comply with RoHS environmental standards.

Hengrui supplies these medical-grade fans worldwide with certified quality assurance, backup inventory and fast logistics to support critical healthcare operations. Browse the available models to find the exact cooling solution for your medical equipment specifications.

How to Select the Right Medical Equipment

The most reliable way to specify medical Equipment is to work from the system, not from the catalog. Measure or calculate the airflow and pressure demand first, add the dimensional limits of the mounting position, and only then shortlist series whose curves cover your operating point with margin.

Electrical matching is the next gate. Confirm the supply voltage — 12 V, 24 V or 48 V DC for compact electronics cooling, 115 V or 230 V AC for equipment and panel cooling — and decide whether you need speed control. EC models accept PWM or 0-10 V signals and report speed through a tachometer output, which makes them the default choice for variable-airflow systems, while AC units remain a cost-effective answer for fixed-speed duty.

Then filter by environment. High ambient temperature, dust or moisture loads dictate the IP rating and bearing choice — ball bearings keep airflow and noise stable over years, while sleeve bearings suit light-duty horizontal mounting. Regulatory needs such as UL, CE and RoHS recognition should be confirmed before the shortlist goes to purchasing, together with a maximum allowed sound pressure level in dBA.

End the process by checking supply, not just specification: confirm current stock, the lead time for follow-up quantities, and obtain datasheets and dimension drawings so the mechanical interface is verified before the PO. Send us your airflow and pressure requirements and our engineers will confirm the best-matched series — 23 products are available in this category today.

Typical Applications and Use Cases for Medical Equipment

The daily work of our sales engineers is built around medical Equipment used in data center cooling, refrigeration and cold chain projects, building ventilation, telecom base stations, medical devices and industrial control cabinets — environments where a stopped fan is a stopped business process. That daily exposure to real installations is exactly what we bring back into every selection: not just reading curves, but knowing which models survive dust, heat, continuous duty and restricted service access.

A typical case: an equipment builder needed to replace an aging AC fan inside a control cabinet that could not be taken offline for more than an hour. By cross-referencing the frame dimensions, voltage and airflow curve, we supplied a current-series drop-in replacement with a matching tachometer signal, and the swap was completed during a scheduled maintenance window.

Refrigeration and cold chain customers bring us another pattern: the failed condenser fan is unavailable for weeks. Comparing diameter, speed, bearings and IP rating, we supply a functionally equivalent unit from stock so the system returns to duty the same week — the reason many service companies keep our contact number on file.

From one-piece emergency replacements to volume supply for equipment manufacturers, every enquiry is handled by the same rule: verify the parameters first, then quote — so what arrives on site is the fan the project actually needs.

Frequently Asked Questions About Buying Medical Equipment

What technical documentation do you provide before purchase?

Datasheets, performance curves, dimension drawings and certification files (UL, CE, RoHS where applicable) are available on request before you buy — we believe a purchase order should follow a verified selection, not replace it. For project tenders we can also provide product comparison tables that put the candidate models side by side on the parameters you care about.

Do you have medical Equipment in stock and how fast can you deliver?

Common series and mainstream voltage versions are normally in stock and can ship within a few working days; specialized or customized variants are produced to order and typically require additional production time. Send us the exact model or the required parameters and we will confirm stock, unit price and the earliest shipment date in one reply Currently 23 products in this category are listed online.

Can you replace my existing medical Equipment from another supplier or a discontinued model?

Yes. Replacement supply is one of our core services: we cross-reference the mounting dimensions, voltage, speed and performance curve of your installed unit and propose the closest current-series equivalent. Where the frame or connector differs slightly, we state the difference clearly before you order, so the replacement installs without surprises.

Bag

Bag packaging indicates that a specified quantity of product is packaged by the manufacturer in a bag, sealed pouch, or similar container and sold as a unit without repackaging. It is also used to describe kits/assortments where components are packaged in separate bags according to part number or parametric value, rather than in a compartmentalized box or similar rigid container.