| Mfr Part # | Rated Voltage(V) | Size(mm) | Max.Air Flow(m³/h) | Max.Pressure(Pa) | Input Power(W) | Speed(rpm) | Noise(db) | |
|---|---|---|---|---|---|---|---|---|
![]() W3G910-GV02-01/F03 | ebm-papst 400VAC 2880W EC Axial Fan for air handling and HVAC systems W3G910-GV02-01/F03 is a 400 VAC axial fan for data-communications equipment, heat pumps, ventilation systems. Its main supplied feature is axial airflow intended for low-to-moderate system resistance. It also lists a 910 mm size specified in the upload data. Review mounting envelope for system integration. |
400 | 910 | 34930 | 190 | 2880 | 1000 | 74 | |
![]() S3G500-AM56-21/F02 | ebm-papst 230VAC 750W EC Axial Fan for air handling and HVAC systems S3G500-AM56-21/F02 is a 230 VAC axial fan for data-communications equipment, heat pumps, ventilation systems. Its main supplied feature is 1420 rpm rated speed in the supplied parameter row. It also lists a 500 mm size specified in the upload data. Review mounting envelope for replacement review. |
230 | 500 | 9245 | 175 | 750 | 1420 | 66 | |
![]() W3G800-GV01-01/F02 | ebm-papst 400VAC 2980W EC Axial Fan for air handling and HVAC systems W3G800-GV01-01/F02 is a 400 VAC axial fan for data-communications equipment, heat pumps, ventilation systems. Its main supplied feature is a 800 mm size specified in the upload data. It also lists 18115 m³/h maximum airflow stated for this model. Review air direction for final model confirmation. |
400 | 800 | 18115 | 260 | 2980 | 1090 | 70 | |
![]() A3G400-BK13-P1 | ebm-papst 110VAC 460W 400mm EC Axial Fan for air handling and HVAC systems A3G400-BK13-P1 is a 110 VAC axial fan for data-communications equipment, heat pumps, ventilation systems. Its main supplied feature is 1670 rpm rated speed in the supplied parameter row. It also lists a 400 mm size specified in the upload data. Review duct connection for procurement comparison. |
110 | 400 | 3400 | 170 | 460 | 1670 | - | |
![]() W3G300-QX25-23 | ebm-papst 26V 400W EC Axial Fan for Air Handling Cooling Suited to Air Handling Cooling, the ebm-papst W3G300-QX25-23 is a 26 V EC axial fan, distinguished by a listed pressure capability of 400 Pa. It gives project engineers a selection cue. |
26 | 300 | 3160 | 400 | 400 | 3800 | 80 | |
![]() W3G910-LV12-03/F01 | ebm-papst 400V 3250W EC Axial Fan for Industrial Cooling Used in Industrial Cooling, ebm-papst W3G910-LV12-03/F01 is a 400 V EC axial fan, whose supplied data highlights a listed airflow of 35,825 m³/h. The rating aids system-fit checks. |
400 | 910 | 35825 | 300 | 3250 | 1070 | 84 | |
![]() W3G300-BV24-01 | ebm-papst 26V 205W EC Axial Fan for Air Handling Cooling Aimed at Air Handling Cooling, ebm-papst W3G300-BV24-01 is a 26 V EC axial fan, defined by a documented speed of 3,160 rpm. This helps guide installation planning. Its documented data supports integration planning. |
26 | 300 | 2570 | 244 | 205 | 3160 | 74 | |
![]() W3G800-GO84-01 | ebm-papst 3~380-480V 835W EC Axial Fan for Industrial Cooling Assigned to Industrial Cooling, ebm-papst W3G800-GO84-01 is a 380-480V EC axial fan, showing a listed acoustic value of 62 dB. It provides a traceable selection parameter. Its documented data supports integration planning. |
3`380-480 | 800 | 18480 | 110 | 835 | 735 | 62 | |
![]() W3G910-LU25-03 | ebm-papst 400V 2500W EC Axial Fan for Industrial Cooling Used in Industrial Cooling, ebm-papst W3G910-LU25-03 is a 400 V EC axial fan, recognized through a listed airflow of 32,930 m³/h. This guides model-to-system comparison. Its documented data supports integration planning. |
400 | 910 | 32930 | 260 | 2500 | 980 | 82 | |
![]() W3G280-EQ20-43 | ebm-papst 26V 200W EC Axial Fan for Air Handling Cooling Adapted for Air Handling Cooling, ebm-papst W3G280-EQ20-43 is a 26 V EC axial fan, presenting a documented speed of 3,100 rpm. It supports an evidence-based shortlist. Its documented data supports integration planning. |
26 | 280 | - | - | 200 | 3100 | - | |
![]() W3G200-HD01-01 | ebm-papst 1~ 200-240V 54W EC Axial Fan for Air Handling Cooling Created for Air Handling Cooling, ebm-papst W3G200-HD01-01 is a 200-240V EC axial fan, defined by a listed acoustic value of 64 dB. The data helps compare W-series variants. Its documented data supports integration planning. |
1~ 200-240 | 225*225*80 | 1000 | 96 | 54 | 2900 | 64 | |
![]() W3G710-GU23-03 | ebm-papst 400V 3700W EC Axial Fan for Air Handling Cooling Suited to Air Handling Cooling, ebm-papst W3G710-GU23-03 is a 400 V EC axial fan, built around a listed airflow of 26,785 m³/h. It gives engineers a clear comparison point. Its documented data supports integration planning. |
400 | 710 | 26785 | 320 | 3700 | 1360 | 79 | |
![]() W3G800-GU25-01 | ebm-papst 3~380-480V 2560W EC Axial Fan for Industrial Cooling Selected for Industrial Cooling, ebm-papst W3G800-GU25-01 is a 380-480V EC axial fan, using a listed airflow of 26,600 m³/h. The value helps verify equipment fit. Its documented data supports integration planning. |
3`380-480 | 800 | 26600 | 230 | 2560 | 1020 | 74 | |
![]() W3G650-CK02-03 | ebm-papst 3~380-480V 2870W EC Axial Fan for Air Handling Assigned to Air Handling, ebm-papst W3G650-CK02-03 is a 380-480V EC axial fan, supported by a listed pressure capability of 325 Pa. It provides a traceable selection parameter. Its documented data supports integration planning. |
3`380-480 | 650 | 21180 | 325 | 2870 | 1500 | 79 | |
![]() W3G630-GN37-23 | ebm-papst 1~ 200-277V 730W EC Axial Fan for Air Handling Serving Air Handling, ebm-papst W3G630-GN37-23 is a 200-277V EC axial fan, identified by a documented speed of 960 rpm. This assists electrical and mechanical review. Its documented data supports integration planning. |
1~ 200-277 | 630 | - | 120 | 730 | 960 | - | |
![]() W3G385-BV44-12 | ebm-papst 26V 245W EC Axial Fan for Air Handling Cooling Assigned to Air Handling Cooling, the ebm-papst W3G385-BV44-12 is a 26 V EC axial fan, documented with 385 mm dimensions for installation planning. It provides a traceable selection parameter. |
26 | 385 | - | - | 245 | 2580 | - | |
![]() W3G385-BV44-01 | ebm-papst 26V 250W EC Axial Fan for Air Handling Cooling Serving Air Handling Cooling, ebm-papst W3G385-BV44-01 is a 26 V EC axial fan, showing a listed pressure capability of 254 Pa. The figure helps confirm design suitability. Its documented data supports integration planning. |
26 | 385 | 3425 | 254 | 250 | 2600 | - | |
![]() W3G300-RQ30-51 | ebm-papst 26V 185W EC Axial Fan for Air Handling Cooling Selected for Air Handling Cooling, ebm-papst W3G300-RQ30-51 is a 26 V EC axial fan, recognized through a documented speed of 2,850 rpm. This supports duty-point selection. Its documented data supports integration planning. |
26 | 300 | - | - | 185 | 2850 | - | |
![]() W3G300-HH13-10 | ebm-papst 26V EC Axial Fan for Air Handling Cooling Focused on Air Handling Cooling, the ebm-papst W3G300-HH13-10 is a 26 V EC axial fan, for which the table lists 300 mm dimensions for installation planning. It gives engineers a clear comparison point. |
26 | 300 | - | - | - | - | - | |
![]() W3G300-RQ28-56 | ebm-papst 27.5V 320W EC Axial Fan for Air Handling Cooling Serving Air Handling Cooling, the ebm-papst W3G300-RQ28-56 is a 27.5 V EC axial fan, combining its format with a documented speed of 3,380 rpm. It gives project engineers a selection cue. |
27.5 | 300 | - | - | 320 | 3380 | - |
The most reliable way to specify EC Axial is to work from the system, not from the catalog. Measure or calculate the airflow and pressure demand first, add the dimensional limits of the mounting position, and only then shortlist series whose curves cover your operating point with margin.
Electrical matching is the next gate. Confirm the supply voltage — 12 V, 24 V or 48 V DC for compact electronics cooling, 115 V or 230 V AC for equipment and panel cooling — and decide whether you need speed control. EC models accept PWM or 0-10 V signals and report speed through a tachometer output, which makes them the default choice for variable-airflow systems, while AC units remain a cost-effective answer for fixed-speed duty.
Then filter by environment. High ambient temperature, dust or moisture loads dictate the IP rating and bearing choice — ball bearings keep airflow and noise stable over years, while sleeve bearings suit light-duty horizontal mounting. Regulatory needs such as UL, CE and RoHS recognition should be confirmed before the shortlist goes to purchasing, together with a maximum allowed sound pressure level in dBA.
End the process by checking supply, not just specification: confirm current stock, the lead time for follow-up quantities, and obtain datasheets and dimension drawings so the mechanical interface is verified before the PO. Send us your airflow and pressure requirements and our engineers will confirm the best-matched series — 129 products are available in this category today.
The daily work of our sales engineers is built around EC Axial used in data center cooling, refrigeration and cold chain projects, building ventilation, telecom base stations, medical devices and industrial control cabinets — environments where a stopped fan is a stopped business process. That daily exposure to real installations is exactly what we bring back into every selection: not just reading curves, but knowing which models survive dust, heat, continuous duty and restricted service access.
A typical case: an equipment builder needed to replace an aging AC fan inside a control cabinet that could not be taken offline for more than an hour. By cross-referencing the frame dimensions, voltage and airflow curve, we supplied a current-series drop-in replacement with a matching tachometer signal, and the swap was completed during a scheduled maintenance window.
Refrigeration and cold chain customers bring us another pattern: the failed condenser fan is unavailable for weeks. Comparing diameter, speed, bearings and IP rating, we supply a functionally equivalent unit from stock so the system returns to duty the same week — the reason many service companies keep our contact number on file.
From one-piece emergency replacements to volume supply for equipment manufacturers, every ebmpapst enquiry is handled by the same rule: verify the parameters first, then quote — so what arrives on site is the fan the project actually needs.
Single-piece orders and samples are welcome — many customers validate one unit in their system before committing to volume. There is no minimum order quantity for standard stock models, and the sample price is deducted from the bulk order in most repeat purchases. Tell us the quantity you plan to use and we will quote both scenarios.
Yes. Beyond catalogue models we can discuss modified lead wires, connectors, speed curves, IP upgrades or private-label packaging for OEM projects. Customization usually starts from a defined annual quantity; our engineers will review your requirement and confirm feasibility, tooling cost and lead time before any commitment.
Every unit is covered by the manufacturer's warranty against defects in materials and workmanship, and we support you through the whole claim process so you deal with one supplier instead of chasing a factory overseas. If a failure appears in service, send us the serial number, operating conditions and photos, and we will arrange the replacement or credit path agreed in the quotation.
Bag
Bag packaging indicates that a specified quantity of product is packaged by the manufacturer in a bag, sealed pouch, or similar container and sold as a unit without repackaging. It is also used to describe kits/assortments where components are packaged in separate bags according to part number or parametric value, rather than in a compartmentalized box or similar rigid container.