Get Quote
Home > Products > By brand > FULLTECH > Tangential Fans

Tangential Fans

By type

By industry

Rated Voltage(V)

Size(mm)

Max.Air Flow(m³/h)

Max.Pressure(Pa)

Input Power(W)

Speed(rpm)

Noise(db)

Stocking Options

Environmental Options

Media

Exclude

1 results

Applied Filters

Showing
1-1
1-1
of 1
Download Table
Mfr Part # Rated Voltage(V) Size(mm) Max.Air Flow(m³/h) Max.Pressure(Pa) Input Power(W) Speed(rpm) Noise(db)
UF-9060CBP23HL | Fulltech 230VAC 160W Tangential Fan for Air Curtain and Cabinet Ventilation

Fulltech UF-9060CBP23HL provides 230 VAC tangential fan cooling for air curtains and cabinet ventilation from a 滚轮Ø90 × 600 mm format. Its die-cast aluminum frame is the representative structural feature; ball bearings and documented electrical connection are also documented. Rated data: 160 W input, up to 901 m³/h, 2100 rpm, 54 dB.

230 740*150*130 901 - 160 2100 54
Showing
1-1
1-1
of 1

About Tangential Fans

Tangential fans — sometimes catalogued simply as tangential blowers — represent a specialised fan category producing wide, flat airflow suitable for applications requiring uniform air distribution across a plane much broader than the fan diameter. In industrial and commercial contexts, tangential fans excel at air curtain installations (invisible air barriers across loading docks and retail entrances), forced-convection ovens and dryers, wide-duct HVAC supply plenums, and electronic enclosures requiring side-to-side temperature uniformity. Compared with axial fans, tangential models move less air per unit of power but deliver far superior flow uniformity across their output width. Compared with centrifugal fans, they produce lower static pressure but occupy a more compact rectangular footprint. Hengrui maintains a complete inventory of tangential fans from Fulltech (the world leading cross flow fan manufacturer), SUNON, ebm-papst, and Sanyo Denki, with impeller lengths ranging from 150mm to 1,500mm and AC or DC motor options. Key selection considerations include airflow width requirement, airflow volume, noise limits, and mounting orientation. Contact Hengrui for custom impeller lengths and competitive wholesale pricing.

How to Select the Right Tangential Fans

Choosing the right tangential Fans starts with the operating point rather than the model name. Define the airflow you actually need in CFM or m³/h and the static pressure the fan must overcome, then look for units whose performance curves pass through that point with a safety margin instead of sitting at the edge of the curve.

Pay attention to the electrical details early. DC fans typically run on 12/24/48 V and integrate easily with control boards, while AC fans suit 115/230 V fixed-speed installations. If the airflow must change with load, choose EC technology with PWM or analog control and, where monitoring matters, a tachometer output so the controller can detect fan failure.

Environment and compliance come next. Match the IP rating to dust and moisture exposure, prefer ball bearings wherever the fan runs hot, vertically or around the clock, and confirm certifications — UL, CE, RoHS — against your destination market. Setting the acoustic limit in dBA early prevents late-stage redesign when the first unit proves too loud.

Finally, compare candidates on total delivery risk, not only on price: confirm stock for the quantity you need, check the lead time for the next batch, and ask for datasheets and dimension drawings before committing. Our team cross-checks curves, dimensions and electrical data for you before quotation There are currently 1 items in this category ready to compare.

Typical Applications and Use Cases for Tangential Fans

Tangential Fans appear in almost every sector where heat or stale air must be moved reliably. Typical environments include server rooms and data centers, refrigeration condensers and cold-store evaporators, HVAC air handling units, telecom cabinets, medical and laboratory equipment, welding and CNC machine enclosures, and renewable-energy power cabinets. In each of these settings the fan is a critical component: its failure stops production, damages stored goods or forces expensive emergency downtime.

One recurring scenario comes from control cabinet retrofits: the original fan is obsolete, the mounting hole pattern cannot change, and downtime is measured in hours. We match the old unit against current series by frame size, airflow and noise, propose the closest drop-in alternative, and ship with a datasheet that lets the electrician connect it without redesign.

For cold storage operators the pain is simple: a failed evaporator or condenser fan must be replaced now, not after a six-week import cycle. Matching blade diameter, speed and protection class against stocked equivalents lets us restore cooling capacity within days, which is why replacement supply has become a core part of this category for us.

Whether the project involves new equipment or the replacement of installed FULLTECH units, the workflow is the same: send us the operating point and constraints, and we return a validated selection with datasheets, curves and a clear lead time.

Frequently Asked Questions About Buying Tangential Fans

Do you support customized or OEM versions of tangential Fans?

Yes. Beyond catalogue models we can discuss modified lead wires, connectors, speed curves, IP upgrades or private-label packaging for OEM projects. Customization usually starts from a defined annual quantity; our engineers will review your requirement and confirm feasibility, tooling cost and lead time before any commitment.

What warranty and after-sales support do you provide?

Every unit is covered by the manufacturer's warranty against defects in materials and workmanship, and we support you through the whole claim process so you deal with one supplier instead of chasing a factory overseas. If a failure appears in service, send us the serial number, operating conditions and photos, and we will arrange the replacement or credit path agreed in the quotation.

What technical documentation do you provide before purchase?

Datasheets, performance curves, dimension drawings and certification files (UL, CE, RoHS where applicable) are available on request before you buy — we believe a purchase order should follow a verified selection, not replace it. For project tenders we can also provide product comparison tables that put the candidate models side by side on the parameters you care about.

Bag

Bag packaging indicates that a specified quantity of product is packaged by the manufacturer in a bag, sealed pouch, or similar container and sold as a unit without repackaging. It is also used to describe kits/assortments where components are packaged in separate bags according to part number or parametric value, rather than in a compartmentalized box or similar rigid container.