| Mfr Part # | Rated Voltage(V) | Size(mm) | Max.Air Flow(m³/h) | Max.Pressure(Pa) | Input Power(W) | Speed(rpm) | Noise(db) | |
|---|---|---|---|---|---|---|---|---|
![]() 109S074UL | SANYO DENKI 115VAC 18/16W 120x120x38mm AC Axial Fan for data center cooling 109S074UL is a 115 VAC axial fan for servers, data-communications equipment, control cabinets. Its main supplied feature is a 120*120*38 mm size specified in the upload data. It also lists 150 m³/h maximum airflow stated for this model. Review air direction for motor selection. Check the exact variant before ordering. |
115 | 120*120*38 | 150 | 57.9/68.7 | 18/16 | 2700/3100 | 42/45 | |
![]() 109-602 | SANYO DENKI 200VAC 37.5W AC Axial Fan for servers and data communications equipment 109-602 is a 200 VAC axial fan for servers, data-communications equipment, control cabinets. Its main supplied feature is a 160*160*51 mm size specified in the upload data. It also lists 432 m³/h maximum airflow stated for this model. Review control method for energy review. Check the exact variant before ordering. |
200 | 160*160*51 | 432 | 156.8 | 37.5 | 2850 | 56 | |
![]() 109-603 | SANYO DENKI 230VAC 37.5W AC Axial Fan for servers and data communications equipment 109-603 is a 230 VAC axial fan for servers, data-communications equipment, control cabinets. Its main supplied feature is 56 dB noise data recorded for this model. It also lists a 160*160*51 mm size specified in the upload data. Review system resistance for compatibility checking. Check the exact variant before ordering. |
230 | 160*160*51 | 432 | 156.8 | 37.5 | - | 56 | |
![]() 109-601 | SANYO DENKI 100VAC 37.5W AC Axial Fan for servers and data communications equipment 109-601 is a 100 VAC axial fan for servers, data-communications equipment, control cabinets. Its main supplied feature is a 160*160*51 mm size specified in the upload data. It also lists 432 m³/h maximum airflow stated for this model. Review pressure requirement for compatibility checking. |
100 | 160*160*51 | 432 | 156.8 | 37.5 | 2850 | 56 | |
![]() 109S072UL | SANYO DENKI 230VAC 18W AC Axial Fan for servers and data communications equipment 109S072UL is a 230 VAC axial fan for servers, data-communications equipment, control cabinets. Its main supplied feature is 57.9 Pa maximum pressure stated for this model. It also lists a 120*120*38 mm size specified in the upload data. Review control method for site verification. Check the exact variant before ordering. |
230 | 120*120*38 | 150 | 57.9 | 18 | 2700 | 42 | |
![]() 109S082 | Sanyo Denki 200VAC 9.5/8.5W AC Axial Fan for automation and control cabinet cooling Within servers, UPS systems, and telecom equipment, Sanyo Denki 109S082 operates as a 120 × 120 × 25 mm AC axial fan at 200 VAC. The series cooling function is confirmed; suffix-specific options require datasheet verification. Its 2200/2350 rpm rating defines a lower-speed operating point. Selection focus: cooling margin validation operating point. |
200 | 120*120*25 | 102 | 29.4/26.5 | 9.5/8.5 | 2200/2350 | 34/35 | |
![]() 109S053 | Sanyo Denki 115VAC San Ace AC Axial Fan for automation and control cabinet cooling A 80×80×25 mm frame and 115 VAC rating define 109S053, a AC axial fan for servers, UPS systems, and telecom equipment. Series options require suffix verification. The 80×80×25 mm format is the primary stated selection detail. Check compatibility risk checking supply requirement. Focus: compatibility risk checking supply requirement. |
115 | 80×80×25 | - | - | - | - | - | |
![]() 109S051 | Sanyo Denki 200VAC 9/7W AC Axial Fan for automation and control cabinet cooling The 109S051 is a Sanyo Denki 200 VAC, 80 × 80 × 25 mm AC axial fan for servers, UPS systems, and telecom equipment. Series options require suffix verification. For compatibility checking, start with the supplied pressure capability. Review connector, alarm, and sensor options separately. Focus: service access planning installation footprint. |
200 | 80*80*25 | 37.8/45.6 | 27.5/38.3 | 9/7 | 2650/3100 | 30/33 | |
![]() 109-043UL | Sanyo Denki 115VAC 9W AC Axial Fan for automation and control cabinet cooling The 109-043UL is a Sanyo Denki 115 VAC, 80 × 80 × 42 mm AC axial fan for servers, UPS systems, and telecom equipment. Series options require suffix verification. Review its mounting size during power-budget planning. Confirm control inputs against the complete ordering code. Focus: service access planning ventilation capacity. |
115 | 80*80*42 | 59.3 | 35.4 | 9 | 3100 | 44 | |
![]() 109S478UL | Sanyo Denki 200VAC AC Axial Fan for automation and control cabinet cooling Sanyo Denki 109S478UL combines a 120×120×38 mm AC axial fan platform with a 200 VAC rating for servers, UPS systems, and telecom equipment. The series cooling function is confirmed; suffix-specific options require datasheet verification. The 120×120×38 mm format is the primary stated selection detail. Focus: service access planning mounting size. |
200 | 120×120×38 | - | - | - | - | - | |
![]() 109S006 | Sanyo Denki 100VAC San Ace AC Axial Fan for automation and control cabinet cooling For thermal management in servers, UPS systems, and telecom equipment, the 109S006 provides a 100 VAC AC axial fan configuration measuring 120×120×38 mm. The 120×120×38 mm format is the primary stated selection detail. During airflow-path design, compare the model's power demand. Use the latest specification for frequency and tolerance limits. |
100 | 120×120×38 | - | - | - | - | - | |
![]() 109044UL | Sanyo Denki 230VAC 9W AC Axial Fan for automation and control cabinet cooling The 80 × 80 × 42 mm Sanyo Denki 109044UL brings 230 VAC AC axial fan cooling to servers, UPS systems, and telecom equipment. Series options require suffix verification. For procurement comparison, start with the supplied motor input. Treat bearing and life data as suffix-specific. Focus: procurement data comparison thermal-duty record. |
230 | 80*80*42 | 59.3 | 35.4 | 9 | 3100 | 44 | |
![]() 109S025 | Sanyo Denki 230VAC 12W AC Axial Fan for automation and control cabinet cooling Within servers, UPS systems, and telecom equipment, Sanyo Denki 109S025 operates as a 119 × 119 × 38 mm AC axial fan at 230 VAC. The series cooling function is confirmed; suffix-specific options require datasheet verification. Its 3100 rpm rating defines a lower-speed operating point. Selection focus: wiring scheme review performance curve. |
230 | 119*119*38 | 160.2 | 65.7 | 12 | 3100 | 43 | |
![]() 109S096 | Sanyo Denki 100VAC 6W AC Axial Fan for automation and control cabinet cooling 109S096 addresses servers, UPS systems, and telecom equipment through a 100 VAC AC axial fan platform measuring 92 × 92 × 25 mm. The series cooling function is confirmed; suffix-specific options require datasheet verification. Its 1700 rpm rating defines a lower-speed operating point. Selection focus: wiring scheme review electrical load. |
100 | 92*92*25 | 38.6 | 16.2 | 6 | 1700 | 27 | |
![]() 109S005UL | Sanyo Denki 100VAC 12W AC Axial Fan for automation and control cabinet cooling The 109S005UL is a Sanyo Denki 100 VAC, 119 × 119 × 38 mm AC axial fan for servers, UPS systems, and telecom equipment. Series options require suffix verification. For equipment integration, start with the supplied acoustic value. Match the exact part number before approving a substitute. Focus: wiring scheme review speed benchmark. |
100 | 119*119*38 | 160.2 | 65.7 | 12 | 3100 | 43 | |
![]() 109S054 | Sanyo Denki 230VAC 7W AC Axial Fan for automation and control cabinet cooling The 109S054 is a Sanyo Denki 230 VAC, 80 × 80 × 25 mm AC axial fan for servers, UPS systems, and telecom equipment. Series options require suffix verification. For airflow-path design, start with the supplied performance curve. Review connector, alarm, and sensor options separately. Focus: control interface planning suffix definition. |
230 | 80*80*25 | 45.2 | 38.4 | 7 | 3100 | 33 | |
![]() 109S024UL | Sanyo Denki 115VAC 12W AC Axial Fan for automation and control cabinet cooling Within servers, UPS systems, and telecom equipment, Sanyo Denki 109S024UL operates as a 119 × 119 × 38 mm AC axial fan at 115 VAC. The series cooling function is confirmed; suffix-specific options require datasheet verification. Its 3100 rpm rating defines a lower-speed operating point. Selection focus: control interface planning mounting size. |
115 | 119*119*38 | 160.2 | 65.7 | 12 | 3100 | 43 | |
![]() 9AD1201H121 | Sanyo Denki 100~240VAC 4.4W ACDC Axial Fan for AC-powered equipment cooling The 120 × 120 × 38 mm Sanyo Denki 9AD1201H121 brings 100~240 VDC DC axial fan cooling to industrial equipment cooling. Series options require suffix verification. Review its installation footprint during procurement comparison. Obtain the applicable curve before final duty-point approval. Focus: control interface planning static-pressure entry. |
100~240 | 120*120*38 | 180.2 | 84.7 | 4.4 | 3250 | 42 | |
![]() 109S-074UL | Sanyo Denki 115VAC 16W AC Axial Fan for automation and control cabinet cooling The 119 × 119 × 38 mm Sanyo Denki 109S-074UL brings 115 VAC AC axial fan cooling to servers, UPS systems, and telecom equipment. Series options require suffix verification. Review its thermal-duty record during duty-point matching. Treat bearing and life data as suffix-specific. Focus: control interface planning power demand. |
115 | 119*119*38 | 172.2 | 68.7 | 16 | 3100 | 45 | |
![]() 109S085 | Sanyo Denki 100VAC 12W AC Axial Fan for automation and control cabinet cooling The 109S085 is a Sanyo Denki 100 VAC, 119 × 119 × 25 mm AC axial fan for servers, UPS systems, and telecom equipment. Series options require suffix verification. Base power-budget planning on the stated selection parameters. Use the latest specification for frequency and tolerance limits. Focus: mounting geometry validation rotational rating. |
100 | 119*119*25 | 136.8 | 53.9 | 12 | 2900 | 41 |
Before comparing models of san Ace Ac Fan, write down the real operating requirements: required airflow, system static pressure, available installation space and the electrical supply on site. A selection that ignores any of these four factors usually ends in returned goods or on-site retrofits.
Voltage and control define the shortlist. Standard options include 12/24/48 V DC and 115/230 V AC; for applications where operating points move, EC fans with PWM or 0-10 V input give precise speed control, and a tach signal provides the feedback many safety systems require.
Environmental conditions eliminate unsuitable models faster than any catalog filter. Check the ambient temperature range, required IP protection for dust and moisture, and the expected service life — ball-bearing units hold their noise and airflow figures far longer than sleeve-bearing designs in vertical or high-temperature positions. If the equipment must ship into regulated markets, verify UL, CE and RoHS compliance at this stage, and set a realistic noise target in dBA so acoustic requirements do not surface after installation.
Close the selection by de-risking the order: verify stock levels, confirm production lead time, and request datasheets plus dimension drawings for the final candidates so the mounting holes and connectors are checked before purchase. Share your operating point with us and we will validate the fit 44 products in this category are ready for comparison.
Across our project record, san Ace Ac Fan are specified wherever equipment must stay cool and air must keep moving: data centers and server rooms, commercial refrigeration, air handling and ventilation systems, telecom and battery cabinets, industrial machinery, and power electronics in the new-energy sector. What these projects share is a simple truth — the fan is small in cost but decisive for uptime, so it deserves the same engineering attention as the equipment it protects.
In a recent retrofit project, a customer's cooling unit had to keep running while its worn fan was exchanged. We identified a current-series replacement with identical mounting dimensions and an equivalent airflow-pressure curve, confirmed the tach output compatibility, and the installation was finished within a single maintenance window.
A second frequent case is refrigeration service: a condenser or evaporator fan fails and the exact original model is on long lead time. Instead of waiting, we check bearing type, IP rating, blade diameter and speed, then offer an equivalent that restores capacity immediately — one of the most common ways our stock protects cold chain operations.
New builds and replacement projects on Sanyo equipment follow the same path at our company: you send the required airflow, pressure and dimensions; we respond with a shortlist, performance curves and firm delivery dates.
Yes. Replacement supply is one of our core services: we cross-reference the mounting dimensions, voltage, speed and performance curve of your installed unit and propose the closest current-series equivalent. Where the frame or connector differs slightly, we state the difference clearly before you order, so the replacement installs without surprises.
Single-piece orders and samples are welcome — many customers validate one unit in their system before committing to volume. There is no minimum order quantity for standard stock models, and the sample price is deducted from the bulk order in most repeat purchases. Tell us the quantity you plan to use and we will quote both scenarios.
Yes. Beyond catalogue models we can discuss modified lead wires, connectors, speed curves, IP upgrades or private-label packaging for OEM projects. Customization usually starts from a defined annual quantity; our engineers will review your requirement and confirm feasibility, tooling cost and lead time before any commitment.
Bag
Bag packaging indicates that a specified quantity of product is packaged by the manufacturer in a bag, sealed pouch, or similar container and sold as a unit without repackaging. It is also used to describe kits/assortments where components are packaged in separate bags according to part number or parametric value, rather than in a compartmentalized box or similar rigid container.