| Mfr Part # | Rated Voltage(V) | Size(mm) | Max.Air Flow(m³/h) | Max.Pressure(Pa) | Input Power(W) | Speed(rpm) | Noise(db) | |
|---|---|---|---|---|---|---|---|---|
![]() EEC0252B1-000U-G99 | SUNON 24VDC 5W DC Axial Fan for servers and data communications equipment EEC0252B1-000U-G99 is a 24 VDC axial fan for servers, data-communications equipment, control cabinets. Its main supplied feature is 5 W input power for the listed electrical version. It also lists a 120x120x25 mm size specified in the upload data. Review procurement specification for equipment design. |
24 | 120x120x25 | 183.8 | 69.7 | 5 | 3100 | 44.5 | |
![]() EEC0251B1-000U-A99 | SUNON 12VDC 5.4W 120x120x25mm DC Axial Fan for data center cooling EEC0251B1-000U-A99 is a 12 VDC axial fan for servers, data-communications equipment, control cabinets. Its main supplied feature is 5.4 W input power for the listed electrical version. It also lists a 120x120x25 mm size specified in the upload data. Review replacement fit for equipment design. |
12 | 120x120x25 | 183.8 | 69.7 | 5.4 | 3100 | 44.5 | |
![]() PF60251BX-1000U-A99 | SUNON 12VDC 3.75W DC Centrifugal Blower for data center cooling PF60251BX-1000U-A99 is a 12 VDC centrifugal fan for servers, medical equipment, laboratory equipment. Its main supplied feature is 3.75 W input power for the listed electrical version. It also lists a 60*60*25 mm size specified in the upload data. Review pressure requirement for equipment design. |
12 | 60*60*25 | 68 | - | 3.75 | 8300 | 46 | |
![]() PMD2408PMB1-A(2).GN | SUNON 24VDC 9.6W 80×80×38mm DC Axial Fan for data center cooling PMD2408PMB1-A(2).GN is a 24 VDC axial fan for servers, data-communications equipment, control cabinets. Its main supplied feature is 142.97 m³/h maximum airflow stated for this model. It also lists a 80×80×38 mm size specified in the upload data. Review airflow path for equipment design. |
24 | 80×80×38 | 142.97 | 184.3 | 9.6 | 5700 | 55.2 | |
![]() PF80381BX-1000U-S9H | SUNON 12VDC 48W 80x80x38mm DC Centrifugal Blower for data center cooling PF80381BX-1000U-S9H is a 12 VDC centrifugal fan for servers, medical equipment, laboratory equipment. Its main supplied feature is a 80*80*38 mm size specified in the upload data. It also lists 241.23 m³/h maximum airflow stated for this model. Review duct connection for replacement review. |
12 | 80*80*38 | 241.23 | 871.8 | 48 | 14000 | 59.1 | |
![]() PF80252B3-1000U-G99 | SUNON 24VDC 2.4W 80×80×25mm DC Centrifugal Blower for data center cooling PF80252B3-1000U-G99 is a 24 VDC centrifugal fan for servers, medical equipment, laboratory equipment. Its main supplied feature is 42.5 dB noise data recorded for this model. It also lists a 80×80×25 mm size specified in the upload data. Review cooling margin for replacement review. Check the exact variant before ordering. |
24 | 80×80×25 | 90.05 | 74.73 | 2.4 | 4200 | 42.5 | |
PF80384B1-000U-H99 | SUNON 48VDC 18.24W DC Centrifugal Blower for data center cooling PF80384B1-000U-H99 is a 48 VDC centrifugal fan for servers, medical equipment, laboratory equipment. Its main supplied feature is 10500 rpm rated speed in the supplied parameter row. It also lists a 80*80*38 mm size specified in the upload data. Review acoustic limit for replacement review. |
48 | 80*80*38 | 177.48 | 612.8 | 18.24 | 10500 | 62.6 | |
![]() HA40201V4-1000U-A99 | SUNON 12VDC 0.42W 40x40x20mm DC Axial Fan for data center cooling HA40201V4-1000U-A99 is a 12 VDC axial fan for servers, data-communications equipment, control cabinets. Its main supplied feature is 0.42 W input power for the listed electrical version. It also lists a 40*40*20 mm size specified in the upload data. Review control method for replacement review. |
12 | 40*40*20 | 5.5 | - | 0.42 | 4500 | 12.3 | |
![]() PMD2408PMB2-A(2).GN | SUNON 24VDC 7.2W 80×80×38mm DC Axial Fan for data center cooling PMD2408PMB2-A(2).GN is a 24 VDC axial fan for servers, data-communications equipment, control cabinets. Its main supplied feature is a 80×80×38 mm size specified in the upload data. It also lists 126.58 m³/h maximum airflow stated for this model. Review electrical supply for replacement review. |
24 | 80×80×38 | 126.58 | 141.98 | 7.2 | 4900 | 51.6 | |
![]() MF40200V1-1000U-A99 | SUNON 5VDC 0.79W 40x40x20mm DC Axial Fan for data center cooling MF40200V1-1000U-A99 is a 5 VDC axial fan for servers, data-communications equipment, control cabinets. Its main supplied feature is axial airflow intended for low-to-moderate system resistance. It also lists a 40*40*20 mm size specified in the upload data. Review pressure requirement for replacement review. |
5 | 40*40*20 | 8.9 | - | 0.79 | 7000 | 25.5 | |
![]() EEC0252B3-000U-A99 | SUNON 24VDC 2W DC Axial Fan for servers and data communications equipment EEC0252B3-000U-A99 is a 24 VDC axial fan for servers, data-communications equipment, control cabinets. Its main supplied feature is 75 m³/h maximum airflow stated for this model. It also lists a 120*120*25 mm size specified in the upload data. Review maintenance access for spares planning. |
24 | 120*120*25 | 75 | - | 2 | 2200 | 34 | |
MF60152V1-1000U-A99 | SUNON 24VDC 2.02W 60x60x15mm DC Axial Fan for data center cooling MF60152V1-1000U-A99 is a 24 VDC axial fan for servers, data-communications equipment, control cabinets. Its main supplied feature is 34.2 dB noise data recorded for this model. It also lists a 60*60*15 mm size specified in the upload data. Review housing geometry for ductwork design. Check the exact variant before ordering. |
24 | 60*60*15 | 26.4 | - | 2.02 | 4700 | 34.2 | |
![]() EEC0382B2-000U-A99 | SUNON 24VDC 5.4W 120x120x38mm DC Axial Fan for data center cooling EEC0382B2-000U-A99 is a 24 VDC axial fan for servers, data-communications equipment, control cabinets. Its main supplied feature is 116 m³/h maximum airflow stated for this model. It also lists a 120*120*38 mm size specified in the upload data. Review fan selection for cabinet planning. |
24 | 120*120*38 | 116 | - | 5.4 | 2600 | 44 | |
![]() MF80151V1-1000C-A99 | SUNON 12VDC 1.5W 80×80×15mm DC Axial Fan for data center cooling MF80151V1-1000C-A99 is a 12 VDC axial fan for servers, data-communications equipment, control cabinets. Its main supplied feature is 42.35 Pa maximum pressure stated for this model. It also lists a 80×80×15 mm size specified in the upload data. Review replacement fit for noise assessment. |
12 | 80×80×15 | 62.86 | 42.35 | 1.5 | 3500 | 32.9 | |
![]() MF50152VX-1000U-A99 | SUNON 24VDC 1.32W 50x50x15mm DC Axial Fan for data center cooling MF50152VX-1000U-A99 is a 24 VDC axial fan for servers, data-communications equipment, control cabinets. Its main supplied feature is 77.2 Pa maximum pressure stated for this model. It also lists a 50*50*15 mm size specified in the upload data. Review electrical supply for compatibility checking. |
24 | 50*50*15 | 31.62 | 77.2 | 1.32 | 7200 | 38.1 | |
![]() MF35101V1-1000U-A99 | SUNON 12VDC 0.72W 35x35x10mm DC Axial Fan for data center cooling MF35101V1-1000U-A99 is a 12 VDC axial fan for servers, data-communications equipment, control cabinets. Its main supplied feature is 10000 rpm rated speed in the supplied parameter row. It also lists a 35*35*10 mm size specified in the upload data. Review housing geometry for commissioning review. |
12 | 35*35*10 | 7.2 | - | 0.72 | 10000 | 28 | |
MF80251V3-1000U-A99 | SUNON 12VDC 0.78W 80x80x25mm DC Axial Fan for data center cooling MF80251V3-1000U-A99 is a 12 VDC axial fan for servers, data-communications equipment, control cabinets. Its main supplied feature is a 80*80*25 mm size specified in the upload data. It also lists 33 m³/h maximum airflow stated for this model. Review operating point for commissioning review. |
12 | 80*80*25 | 33 | - | 0.78 | 2600 | 28 | |
![]() PF80251V1-1000U-A99 | SUNON 12VDC 3.72W DC Centrifugal Blower for data center cooling PF80251V1-1000U-A99 is a 12 VDC centrifugal fan for servers, medical equipment, laboratory equipment. Its main supplied feature is 4800 rpm rated speed in the supplied parameter row. It also lists a 80*80*25 mm size specified in the upload data. Review installation clearance for commissioning review. |
12 | 80*80*25 | 60 | - | 3.72 | 4800 | 44.7 | |
![]() MF30101V1-1000U-A99 | SUNON 12VDC 0.83W 30x30x10mm DC Axial Fan for data center cooling MF30101V1-1000U-A99 is a 12 VDC axial fan for servers, data-communications equipment, control cabinets. Its main supplied feature is 11500 rpm rated speed in the supplied parameter row. It also lists a 30*30*10 mm size specified in the upload data. Review equipment interface for site verification. |
12 | 30*30*10 | 5.5 | - | 0.83 | 11500 | 23 | |
![]() PMD2412PMB1-A.GN | SUNON 24VDC 18.2W 120x120x38mm DC Axial Fan for data center cooling PMD2412PMB1-A.GN is a 24 VDC axial fan for servers, data-communications equipment, control cabinets. Its main supplied feature is 54 dB noise data recorded for this model. It also lists a 120x120x38 mm size specified in the upload data. Review fan selection for site verification. Check the exact variant before ordering. |
24 | 120x120x38 | 322.8 | 161.9 | 18.2 | 4200 | 54 |
The most reliable way to specify DC Fans is to work from the system, not from the catalog. Measure or calculate the airflow and pressure demand first, add the dimensional limits of the mounting position, and only then shortlist series whose curves cover your operating point with margin.
Electrical matching is the next gate. Confirm the supply voltage — 12 V, 24 V or 48 V DC for compact electronics cooling, 115 V or 230 V AC for equipment and panel cooling — and decide whether you need speed control. EC models accept PWM or 0-10 V signals and report speed through a tachometer output, which makes them the default choice for variable-airflow systems, while AC units remain a cost-effective answer for fixed-speed duty.
Then filter by environment. High ambient temperature, dust or moisture loads dictate the IP rating and bearing choice — ball bearings keep airflow and noise stable over years, while sleeve bearings suit light-duty horizontal mounting. Regulatory needs such as UL, CE and RoHS recognition should be confirmed before the shortlist goes to purchasing, together with a maximum allowed sound pressure level in dBA.
End the process by checking supply, not just specification: confirm current stock, the lead time for follow-up quantities, and obtain datasheets and dimension drawings so the mechanical interface is verified before the PO. Send us your airflow and pressure requirements and our engineers will confirm the best-matched series — 1,061 products are available in this category today.
The daily work of our sales engineers is built around DC Fans used in data center cooling, refrigeration and cold chain projects, building ventilation, telecom base stations, medical devices and industrial control cabinets — environments where a stopped fan is a stopped business process. That daily exposure to real installations is exactly what we bring back into every selection: not just reading curves, but knowing which models survive dust, heat, continuous duty and restricted service access.
A typical case: an equipment builder needed to replace an aging AC fan inside a control cabinet that could not be taken offline for more than an hour. By cross-referencing the frame dimensions, voltage and airflow curve, we supplied a current-series drop-in replacement with a matching tachometer signal, and the swap was completed during a scheduled maintenance window.
Refrigeration and cold chain customers bring us another pattern: the failed condenser fan is unavailable for weeks. Comparing diameter, speed, bearings and IP rating, we supply a functionally equivalent unit from stock so the system returns to duty the same week — the reason many service companies keep our contact number on file.
From one-piece emergency replacements to volume supply for equipment manufacturers, every SUNON enquiry is handled by the same rule: verify the parameters first, then quote — so what arrives on site is the fan the project actually needs.
Single-piece orders and samples are welcome — many customers validate one unit in their system before committing to volume. There is no minimum order quantity for standard stock models, and the sample price is deducted from the bulk order in most repeat purchases. Tell us the quantity you plan to use and we will quote both scenarios.
Yes. Beyond catalogue models we can discuss modified lead wires, connectors, speed curves, IP upgrades or private-label packaging for OEM projects. Customization usually starts from a defined annual quantity; our engineers will review your requirement and confirm feasibility, tooling cost and lead time before any commitment.
Every unit is covered by the manufacturer's warranty against defects in materials and workmanship, and we support you through the whole claim process so you deal with one supplier instead of chasing a factory overseas. If a failure appears in service, send us the serial number, operating conditions and photos, and we will arrange the replacement or credit path agreed in the quotation.
Bag
Bag packaging indicates that a specified quantity of product is packaged by the manufacturer in a bag, sealed pouch, or similar container and sold as a unit without repackaging. It is also used to describe kits/assortments where components are packaged in separate bags according to part number or parametric value, rather than in a compartmentalized box or similar rigid container.