EEC0252B1-000U-G99 is a 24 VDC axial fan for servers, data-communications equipment, control cabinets. Its main supplied feature is 5 W input power for the listed electrical version. It also lists a 120x120x25 mm size specified in the upload data. Review procurement specification for equipment design.
| Rated Voltage(V) | 24 |
|---|---|
| Size(mm) | 120x120x25 |
| Max.Air Flow(m³/h) | 183.8 |
| Max.Pressure(Pa) | 69.7 |
| Input Power(W) | 5 |
| Speed(rpm) | 3100 |
| Noise(db) | 44.5 |
The EEC0252B1-000U-G99 brings SUNON DC axial fan performance to data centers and communication machinery. It gives engineers a defined component for forced-air thermal management.
Axial air movement is appropriate where volume flow is the primary requirement and the completed installation does not impose excessive resistance.
The fan can reinforce robust operation when its duty point is checked against the complete equipment platform curve and thermal load.
Listed airflow of 183.8 m3/h and pressure of 69.7 Pa provide starting points for duty-point evaluation in the completed equipment platform. Review the approved electrical interface for the complete suffix. Validate sound and temperature in the finished enclosure.
The application of EEC0252B1-000U-G99 covers servers and data-communication hardware; here, the DC axial fan cools computing and network assemblies. Assembly-level validation helps prevent a mechanically similar model from being substituted without compatibility checks.
For assembly in power supplies, inverters and control cabinets, SUNON EEC0252B1-000U-G99 acts as a heat removal component that cools power modules and controls. The assembly benefits from continuous heat removal where passive heat removal alone cannot maintain design margin.
Within industrial automation installation, EEC0252B1-000U-G99 ventilates drives and production electronics as a SUNON DC axial fan. This gives installation makers a practical thermal control element that supports unit reliability without changing the stated industry direction.
The SUNON DC axial fan EEC0252B1-000U-G99 addresses thermal demand in medical and laboratory instruments by helping to cools enclosed instrument electronics. Application resistance can shift delivered ventilation flow away from free-air catalogue values if it is not checked.
No quantified cost-saving claim is supplied for this exact item. Compare energy use, controls, service needs, and purchase cost using the required duty point.
The upload row lists RoHS compliance, but no additional exact-model certification is confirmed in the supplied feature record.
No exact IP protection level is stated for this item in the supplied sources. Confirm it before use in dusty, wet, or harsh locations.
Check supply voltage, controller signals, blocked airflow, contamination, abnormal noise, rotation, and the equipment operating point before replacing the unit.
No model-specific maintenance interval is supplied. Keep the airflow path clean, inspect mounting and electrical connections, and follow the exact product instructions.
The supplied sources do not confirm an integrated controller. Verify the exact electrical variant and control requirement before ordering.

Within telecom cabinets, base stations, and network equipment, SUNON EEC0252B1-000U-G99 serves as a 120 × 120 × 25 mm DC axial fan operating at 24 VDC. Up to 183.8 m³/h is its most prominent listed performance figure. Base noise-control planning on the stated sound level. Confirm environmental protection for the ordered version.
Read More
Within telecom cabinets, base stations, and network equipment, SUNON EEC0382B1-000U-G99 serves as a 120 × 120 × 38 mm DC blower operating at 24 VDC. 9.2 W input is the defining electrical load in the supplied data. During noise-control planning, compare the model's thermal-duty record. Confirm environmental protection for the ordered version.
Read More
The 12 VDC SUNON EEC0381B1-000U-G99 is a DC blower sized 120 × 120 × 38 mm for telecom cabinets, base stations, and network equipment. Up to 234.09 m³/h is its most prominent listed performance figure. Base wiring review on the stated supply requirement. Confirm environmental protection for the ordered version.
Read More
The EEC0251B2-000U-G99 is SUNON's 12 VDC, 120 × 120 × 25 mm DC axial fan option for telecom cabinets, base stations, and network equipment. Its 2700 rpm rating defines a lower-speed operating point. For airflow-path design, start with the supplied volume-flow figure. Obtain the applicable curve before final duty-point approval.
Read More
Specified at 24 VDC, EEC0252B3-000U-G99 is a SUNON DC axial fan for telecom cabinets, base stations, and network equipment in 120 × 120 × 25 mm dimensions. Its 2200 rpm rating defines a lower-speed operating point. The recorded application data should guide acoustic assessment. Match the exact part number before approving a substitute.
Read More
EEC0251B1-000U-A99 is a 12 VDC axial fan for servers, data-communications equipment, control cabinets. Its main supplied feature is 5.4 W input power for the listed electrical version. It also lists a 120x120x25 mm size specified in the upload data. Review replacement fit for equipment design.
Read More