EEC0382B2-000U-A99 is a 24 VDC axial fan for servers, data-communications equipment, control cabinets. Its main supplied feature is 116 m³/h maximum airflow stated for this model. It also lists a 120*120*38 mm size specified in the upload data. Review fan selection for cabinet planning.
| Rated Voltage(V) | 24 |
|---|---|
| Size(mm) | 120*120*38 |
| Max.Air Flow(m³/h) | 116 |
| Input Power(W) | 5.4 |
| Speed(rpm) | 2600 |
| Noise(db) | 44 |
SUNON EEC0382B2-000U-A99 is a DC axial fan selected for data centers and communication assembly, where controlled air movement protects operating margin in compact or continuously loaded assembly.
The listed 24 V supply and 5.4 W input give electrical designers a defined basis for power and interface planning.
Air enters and leaves in the axial direction, supporting efficient exchange across open enclosures, electronics and ventilation paths.
The result is a practical heat removal component for manufacturers balancing thermal performance, installation space and lifecycle service. Confirm the exact operating point before production release. Preserve the specified air movement direction during assembly.
SUNON supplies model EEC0382B2-000U-A99 for servers and data-communication hardware, where directed temperature management flow cools computing and network assemblies. The result aids reliable operation while keeping the temperature management function understandable for future service work.
Within power supplies, inverters and control cabinets, EEC0382B2-000U-A99 cools power modules and controls as a SUNON DC axial fan. This gives equipment makers a practical temperature management element that helps maintain installation reliability without changing the stated industry direction.
In industrial automation equipment, the SUNON EEC0382B2-000U-A99 provides forced air delivery that ventilates drives and production electronics. Forced-air thermal management supports equipment availability during long duty cycles and repeated load changes.
For installation in medical and laboratory instruments, SUNON EEC0382B2-000U-A99 acts as a thermal control component that cools enclosed instrument electronics. Engineering teams should verify mounting, airflow direction and installation resistance to preserve the intended application value.
Speed-control support is not stated for this exact item in the supplied sources. Confirm the motor and controller version before specifying control hardware.
No guaranteed lead time is provided in the supplied sources. Confirm current stock, required quantity, production schedule, and shipping date with the supplier.
The supplied sources do not confirm an integrated controller. Verify the exact electrical variant and control requirement before ordering.
The supplied files do not establish a universal 24/7 duty rating. Validate ambient conditions, duty cycle, protection, and maintenance requirements for continuous use.
The supplied application data covers servers, data-communications equipment, control cabinets. Confirm the installation's airflow, pressure, space, and electrical requirements.
No quantified cost-saving claim is supplied for this exact item. Compare energy use, controls, service needs, and purchase cost using the required duty point.

SUNON EEC0382B2-000U-A99 is a 24 VDC DC blower in a 120 × 120 × 38 mm format for telecom cabinets, base stations, and network equipment. Its 2600 rpm rating defines a lower-speed operating point. Use the documented motor input when planning enclosure sizing. Verify bearing and signal options in the exact datasheet.
Read More
The EEC0381B2-000U-A99 is SUNON's 12 VDC, 120 × 120 × 38 mm DC blower option for telecom cabinets, base stations, and network equipment. Up to 197.1 m³/h is its most prominent listed performance figure. For noise-control planning, start with the supplied mounting size. Confirm environmental protection for the ordered version.
Read More
EEC0251B1-000U-A99 is a 12 VDC axial fan for servers, data-communications equipment, control cabinets. Its main supplied feature is 5.4 W input power for the listed electrical version. It also lists a 120x120x25 mm size specified in the upload data. Review replacement fit for equipment design.
Read More
EEC0252B3-000U-A99 is a 24 VDC axial fan for servers, data-communications equipment, control cabinets. Its main supplied feature is 75 m³/h maximum airflow stated for this model. It also lists a 120*120*25 mm size specified in the upload data. Review maintenance access for spares planning.
Read More
EEC0252B1-000U-A99 is a 24 VDC axial fan for servers, data-communications equipment, control cabinets. Its main supplied feature is axial airflow intended for low-to-moderate system resistance. It also lists a 120*120*25 mm size specified in the upload data. Review electrical supply for technical approval.
Read More
EEC0382B1-000U-A99 is a 24 VDC axial fan for servers, data-communications equipment, control cabinets. Its main supplied feature is 48 dB noise data recorded for this model. It also lists a 120x120x38 mm size specified in the upload data. Review installation clearance for replacement review.
Read More