Home > Products > By type > Axial Fans > EEC0382B2-000U-A99 | SUNON 24VDC 5.4W 120x120x38mm DC Axial Fan for data center cooling

EEC0382B2-000U-A99 SUNON Axial Fan

Brand :
SUNON
Model:
EEC0382B2-000U-A99 | SUNON 24VDC 5.4W 120x120x38mm DC Axial Fan for data center cooling
Type:
Axial Fans
Industry:
Data Center Cooling
Description:

EEC0382B2-000U-A99 is a 24 VDC axial fan for servers, data-communications equipment, control cabinets. Its main supplied feature is 116 m³/h maximum airflow stated for this model. It also lists a 120*120*38 mm size specified in the upload data. Review fan selection for cabinet planning.

Product Features

Rated Voltage(V)24
Size(mm)120*120*38
Max.Air Flow(m³/h)116
Input Power(W)5.4
Speed(rpm)2600
Noise(db)44

Product Features

Reliable DC Cooling

SUNON EEC0382B2-000U-A99 is a DC axial fan selected for data centers and communication assembly, where controlled air movement protects operating margin in compact or continuously loaded assembly.

The listed 24 V supply and 5.4 W input give electrical designers a defined basis for power and interface planning.

Air enters and leaves in the axial direction, supporting efficient exchange across open enclosures, electronics and ventilation paths.

The result is a practical heat removal component for manufacturers balancing thermal performance, installation space and lifecycle service. Confirm the exact operating point before production release. Preserve the specified air movement direction during assembly.

Application Industry

Frequently Asked Questions

Does EEC0382B2-000U-A99 support speed control?

Speed-control support is not stated for this exact item in the supplied sources. Confirm the motor and controller version before specifying control hardware.

How stable is the lead time for EEC0382B2-000U-A99?

No guaranteed lead time is provided in the supplied sources. Confirm current stock, required quantity, production schedule, and shipping date with the supplier.

Does EEC0382B2-000U-A99 require a separate controller?

The supplied sources do not confirm an integrated controller. Verify the exact electrical variant and control requirement before ordering.

Can EEC0382B2-000U-A99 be considered for continuous operation?

The supplied files do not establish a universal 24/7 duty rating. Validate ambient conditions, duty cycle, protection, and maintenance requirements for continuous use.

What equipment is EEC0382B2-000U-A99 suited to?

The supplied application data covers servers, data-communications equipment, control cabinets. Confirm the installation's airflow, pressure, space, and electrical requirements.

Can EEC0382B2-000U-A99 help reduce operating cost?

No quantified cost-saving claim is supplied for this exact item. Compare energy use, controls, service needs, and purchase cost using the required duty point.