EEC0252B1-000U-A99 is a 24 VDC axial fan for servers, data-communications equipment, control cabinets. Its main supplied feature is axial airflow intended for low-to-moderate system resistance. It also lists a 120*120*25 mm size specified in the upload data. Review electrical supply for technical approval.
| Rated Voltage(V) | 24 |
|---|---|
| Size(mm) | 120*120*25 |
| Max.Air Flow(m³/h) | 108.2 |
| Input Power(W) | 5 |
| Speed(rpm) | 3100 |
| Noise(db) | 44.5 |
Designed around the heat removal needs of data centers and communication system, the SUNON EEC0252B1-000U-A99 provides a DC axial fan format for OEM system integration.
The result is a practical heat removal component for manufacturers balancing thermal performance, installation space and lifecycle service.
Air enters and leaves in the axial direction, supporting efficient exchange across open enclosures, electronics and ventilation paths.
The 3100 rpm speed and 44.5 dB sound entry help maintain system-level thermal and acoustic review. Preserve the specified air movement direction during assembly. Review the approved electrical interface for the complete suffix. Validate sound and temperature in the finished enclosure.
When integrated in servers and data-communication hardware, EEC0252B1-000U-A99 cools computing and network assemblies within the available assembly space. A defined air route enables repeatable thermal behavior across production units and service replacements.
When integrated in power supplies, inverters and control cabinets, EEC0252B1-000U-A99 cools power modules and controls within the available assembly space. The application needs predictable air movement because dense layouts restrict natural convection and heat spreading.
Model EEC0252B1-000U-A99 contributes to industrial automation hardware by providing ventilation flow that ventilates drives and production electronics. Reviewing the exact electrical interface and environmental limits reinforces a safer production release.
Assembly serving medical and laboratory instruments can integrate SUNON EEC0252B1-000U-A99; the unit cools enclosed instrument electronics. Assembly developers should verify mounting, ventilation flow direction and assembly resistance to preserve the intended application value.
Check electrical supply, mounting clearance, fasteners, airflow direction, guards, wiring, and access for service before installation.
Confirm the target equipment, operating point, ambient conditions, installation space, electrical supply, controls, protection, quantity, and required delivery date.
The upload sheet marks the item as In Stock, but available quantity should be confirmed when the order is placed.
The upload row lists 24 VDC. Confirm phase, frequency, terminals, and local supply conditions before wiring.
Speed-control support is not stated for this exact item in the supplied sources. Confirm the motor and controller version before specifying control hardware.
No model-specific maintenance interval is supplied. Keep the airflow path clean, inspect mounting and electrical connections, and follow the exact product instructions.

EEC0251B1-000U-A99 is a 12 VDC axial fan for servers, data-communications equipment, control cabinets. Its main supplied feature is 5.4 W input power for the listed electrical version. It also lists a 120x120x25 mm size specified in the upload data. Review replacement fit for equipment design.
Read More
Designed for telecom cabinets, base stations, and network equipment, SUNON EEC0251B1-000U-A99 is a 12 VDC DC axial fan in a 120 × 120 × 25 mm frame. Up to 183.8 m³/h is its most prominent listed performance figure. Use the documented selection parameters when planning wiring review. Confirm environmental protection for the ordered version.
Read More
EEC0252B3-000U-A99 is a 24 VDC axial fan for servers, data-communications equipment, control cabinets. Its main supplied feature is 75 m³/h maximum airflow stated for this model. It also lists a 120*120*25 mm size specified in the upload data. Review maintenance access for spares planning.
Read More
EEC0382B1-000U-A99 is a 24 VDC axial fan for servers, data-communications equipment, control cabinets. Its main supplied feature is 48 dB noise data recorded for this model. It also lists a 120x120x38 mm size specified in the upload data. Review installation clearance for replacement review.
Read More
EEC0382B3-000U-A99 is a 24 VDC axial fan for servers, data-communications equipment, control cabinets. Its main supplied feature is 93 m³/h maximum airflow stated for this model. It also lists a 120*120*38 mm size specified in the upload data. Review duct connection for replacement review.
Read More
The 120 × 120 × 38 mm EEC0384B2-000U-A99 brings 48 VDC DC axial fan cooling to telecom cabinets, base stations, and network equipment. Up to 197.1 m³/h is its most prominent listed performance figure. Review its equipment fit during noise-control planning. Confirm environmental protection for the ordered version.
Read More