EEC0382B3-000U-A99 is a 24 VDC axial fan for servers, data-communications equipment, control cabinets. Its main supplied feature is 93 m³/h maximum airflow stated for this model. It also lists a 120*120*38 mm size specified in the upload data. Review duct connection for replacement review.
| Rated Voltage(V) | 24 |
|---|---|
| Size(mm) | 120*120*38 |
| Max.Air Flow(m³/h) | 93 |
| Input Power(W) | 3.1 |
| Speed(rpm) | 2100 |
| Noise(db) | 37 |
Hardware makers serving data centers and communication hardware can integrate SUNON EEC0382B3-000U-A99 as a DC axial fan for directed ventilation and component-level heat removal.
Its axial-flow arrangement carries a relatively large air volume along the motor axis, making it suitable for low-to-moderate system resistance.
The listed moving air of 93 m3/h remains subject to the resistance and recirculation of the integrated installation.
Hardware designers gain a traceable forced-air cooling specification that can be reviewed by engineering, purchasing and maintenance teams. Confirm the exact operating point before production release. Preserve the specified moving air direction during assembly. Review the approved electrical interface for the complete suffix.
Model EEC0382B3-000U-A99 contributes to servers and data-communication hardware by providing air movement that cools computing and network assemblies. Reviewing the exact electrical interface and environmental limits contributes to a safer production release.
When in-system in power supplies, inverters and control cabinets, EEC0382B3-000U-A99 cools power modules and controls within the available hardware space. Heat must be transferred toward an exhaust, coil or heat sink before it accumulates around critical parts.
Thermal management in industrial automation assembly can use SUNON EEC0382B3-000U-A99 to ventilates drives and production electronics. The surrounding enclosure, filters and heat exchangers can add resistance that must be considered during selection.
SUNON supplies model EEC0382B3-000U-A99 for medical and laboratory instruments, where directed air movement cools enclosed instrument electronics. Assembly resistance can shift delivered air movement away from free-air catalogue values if it is not checked.
Speed-control support is not stated for this exact item in the supplied sources. Confirm the motor and controller version before specifying control hardware.
The matched source highlights 93 m³/h maximum airflow stated for this model. Compare that point together with the listed electrical and dimensional data.
The supplied sources do not confirm an integrated controller. Verify the exact electrical variant and control requirement before ordering.
It may be evaluated for high-reliability cooling using the supplied parameters, but duty cycle, redundancy, ambient limits, and protection must be confirmed at system level.
The supplied application data covers servers, data-communications equipment, control cabinets. Confirm the installation's airflow, pressure, space, and electrical requirements.
Confirm the target equipment, operating point, ambient conditions, installation space, electrical supply, controls, protection, quantity, and required delivery date.

EEC0251B1-000U-A99 is a 12 VDC axial fan for servers, data-communications equipment, control cabinets. Its main supplied feature is 5.4 W input power for the listed electrical version. It also lists a 120x120x25 mm size specified in the upload data. Review replacement fit for equipment design.
Read More
EEC0252B3-000U-A99 is a 24 VDC axial fan for servers, data-communications equipment, control cabinets. Its main supplied feature is 75 m³/h maximum airflow stated for this model. It also lists a 120*120*25 mm size specified in the upload data. Review maintenance access for spares planning.
Read More
EEC0252B1-000U-A99 is a 24 VDC axial fan for servers, data-communications equipment, control cabinets. Its main supplied feature is axial airflow intended for low-to-moderate system resistance. It also lists a 120*120*25 mm size specified in the upload data. Review electrical supply for technical approval.
Read More
EEC0382B1-000U-A99 is a 24 VDC axial fan for servers, data-communications equipment, control cabinets. Its main supplied feature is 48 dB noise data recorded for this model. It also lists a 120x120x38 mm size specified in the upload data. Review installation clearance for replacement review.
Read More
The 120 × 120 × 38 mm EEC0384B2-000U-A99 brings 48 VDC DC axial fan cooling to telecom cabinets, base stations, and network equipment. Up to 197.1 m³/h is its most prominent listed performance figure. Review its equipment fit during noise-control planning. Confirm environmental protection for the ordered version.
Read More
The EEC0381B2-000U-A99 is SUNON's 12 VDC, 120 × 120 × 38 mm DC blower option for telecom cabinets, base stations, and network equipment. Up to 197.1 m³/h is its most prominent listed performance figure. For noise-control planning, start with the supplied mounting size. Confirm environmental protection for the ordered version.
Read More