Home > Products > By type > Axial Fans > EEC0382B3-000U-A99 | SUNON 24VDC 3.1W 120x120x38mm DC Axial Fan for data center cooling

EEC0382B3-000U-A99 SUNON Axial Fan

Brand :
SUNON
Model:
EEC0382B3-000U-A99 | SUNON 24VDC 3.1W 120x120x38mm DC Axial Fan for data center cooling
Type:
Axial Fans
Industry:
Data Center Cooling
Description:

EEC0382B3-000U-A99 is a 24 VDC axial fan for servers, data-communications equipment, control cabinets. Its main supplied feature is 93 m³/h maximum airflow stated for this model. It also lists a 120*120*38 mm size specified in the upload data. Review duct connection for replacement review.

Product Features

Rated Voltage(V)24
Size(mm)120*120*38
Max.Air Flow(m³/h)93
Input Power(W)3.1
Speed(rpm)2100
Noise(db)37

Product Features

Reliable DC Cooling

Hardware makers serving data centers and communication hardware can integrate SUNON EEC0382B3-000U-A99 as a DC axial fan for directed ventilation and component-level heat removal.

Its axial-flow arrangement carries a relatively large air volume along the motor axis, making it suitable for low-to-moderate system resistance.

The listed moving air of 93 m3/h remains subject to the resistance and recirculation of the integrated installation.

Hardware designers gain a traceable forced-air cooling specification that can be reviewed by engineering, purchasing and maintenance teams. Confirm the exact operating point before production release. Preserve the specified moving air direction during assembly. Review the approved electrical interface for the complete suffix.

Application Industry

Frequently Asked Questions

Does EEC0382B3-000U-A99 support speed control?

Speed-control support is not stated for this exact item in the supplied sources. Confirm the motor and controller version before specifying control hardware.

Which supplied feature distinguishes EEC0382B3-000U-A99?

The matched source highlights 93 m³/h maximum airflow stated for this model. Compare that point together with the listed electrical and dimensional data.

Does EEC0382B3-000U-A99 require a separate controller?

The supplied sources do not confirm an integrated controller. Verify the exact electrical variant and control requirement before ordering.

Is EEC0382B3-000U-A99 suitable for a high-reliability cooling system?

It may be evaluated for high-reliability cooling using the supplied parameters, but duty cycle, redundancy, ambient limits, and protection must be confirmed at system level.

What equipment is EEC0382B3-000U-A99 suited to?

The supplied application data covers servers, data-communications equipment, control cabinets. Confirm the installation's airflow, pressure, space, and electrical requirements.

Which application details should be confirmed before ordering EEC0382B3-000U-A99?

Confirm the target equipment, operating point, ambient conditions, installation space, electrical supply, controls, protection, quantity, and required delivery date.