EEC0382B1-000U-A99 is a 24 VDC axial fan for servers, data-communications equipment, control cabinets. Its main supplied feature is 48 dB noise data recorded for this model. It also lists a 120x120x38 mm size specified in the upload data. Review installation clearance for replacement review.
| Rated Voltage(V) | 24 |
|---|---|
| Size(mm) | 120x120x38 |
| Max.Air Flow(m³/h) | 234.5 |
| Max.Pressure(Pa) | 89.7 |
| Input Power(W) | 9.2 |
| Speed(rpm) | 3100 |
| Noise(db) | 48 |
SUNON EEC0382B1-000U-A99 is a DC axial fan selected for data centers and communication assembly, where controlled moving air protects operating margin in constrained-space or continuously loaded assembly.
Its axial-flow arrangement carries a relatively large air volume along the motor axis, making it suitable for low-to-moderate application resistance.
The listed 24 V supply and 9.2 W input give electrical designers a defined basis for power and interface planning.
Prototype testing can verify the integrated moving air path and prevent free-air data from being mistaken for in-application performance. Confirm the exact operating point before production release. Preserve the specified moving air direction during assembly.
The EEC0382B1-000U-A99 is positioned for servers and data-communication hardware, helping the completed installation cools computing and network assemblies. A confirmed operating point provides a stronger purchasing basis than selecting from maximum air delivery alone.
The EEC0382B1-000U-A99 is positioned for power supplies, inverters and control cabinets, helping the completed unit cools power modules and controls. Sustained service requires an temperature management flow component that integrates cleanly with the installation architecture.
When assembled in industrial automation machinery, EEC0382B1-000U-A99 ventilates drives and production electronics within the available machinery space. The fan becomes part of a documented thermal solution that engineering and procurement teams can review together.
For assembly in medical and laboratory instruments, SUNON EEC0382B1-000U-A99 acts as a forced-air cooling component that cools enclosed instrument electronics. Assembly-level validation helps prevent a mechanically similar model from being substituted without compatibility checks.
The supplied files do not establish a universal 24/7 duty rating. Validate ambient conditions, duty cycle, protection, and maintenance requirements for continuous use.
Check electrical supply, mounting clearance, fasteners, airflow direction, guards, wiring, and access for service before installation.
No quantified cost-saving claim is supplied for this exact item. Compare energy use, controls, service needs, and purchase cost using the required duty point.
The product is classified as a axial fan. Use the full model code because nearby variants can differ in motor, mounting, and controls.
Verify the listed size, mounting pattern, fan housing or nozzle arrangement, airflow direction, and service clearance against the equipment drawing.
Check supply voltage, controller signals, blocked airflow, contamination, abnormal noise, rotation, and the equipment operating point before replacing the unit.

Within telecom cabinets, base stations, and network equipment, SUNON EEC0382B1-000U-A99 serves as a 120 × 120 × 38 mm DC blower operating at 24 VDC. Up to 234.5 m³/h is its most prominent listed performance figure. Treat the equipment fit as a primary input to controller selection. Treat bearing and life data as suffix-specific.
Read More
Applied in telecom cabinets, base stations, and network equipment, SUNON EEC0382B-1000U-A99 is a 24 VDC DC blower in a 120 × 120 × 38 mm frame. Up to 234.5 m³/h is its most prominent listed performance figure. Treat the volume-flow figure as a primary input to noise-control planning. Confirm environmental protection for the ordered version.
Read More
Positioned for telecom cabinets, base stations, and network equipment, SUNON EEC0381B1-000U-A99 is a 12 VDC DC blower in a 120 × 120 × 38 mm frame. Up to 234.5 m³/h is its most prominent listed performance figure. Review its operating point during noise-control planning. Confirm environmental protection for the ordered version.
Read More
EEC0382B1-000UA99 serves telecom cabinets, base stations, and network equipment as a 120 × 120 × 38 mm DC blower rated at 24 VDC. Up to 234.5 m³/h is its most prominent listed performance figure. The recorded electrical load should guide noise-control planning. Confirm environmental protection for the ordered version.
Read More
EEC0251B1-000U-A99 is a 12 VDC axial fan for servers, data-communications equipment, control cabinets. Its main supplied feature is 5.4 W input power for the listed electrical version. It also lists a 120x120x25 mm size specified in the upload data. Review replacement fit for equipment design.
Read More
EEC0252B3-000U-A99 is a 24 VDC axial fan for servers, data-communications equipment, control cabinets. Its main supplied feature is 75 m³/h maximum airflow stated for this model. It also lists a 120*120*25 mm size specified in the upload data. Review maintenance access for spares planning.
Read More