| Mfr Part # | Rated Voltage(V) | Size(mm) | Max.Air Flow(m³/h) | Max.Pressure(Pa) | Input Power(W) | Speed(rpm) | Noise(db) | |
|---|---|---|---|---|---|---|---|---|
MB40201V1-0000-G99 | SUNON 12VDC 0.84W 40×40×20mm DC Centrifugal Blower for data center cooling MB40201V1-0000-G99 is a 12 VDC centrifugal fan for servers, medical equipment, laboratory equipment. Its main supplied feature is 0.84 W input power for the listed electrical version. It also lists a 40×40×20 mm size specified in the upload data. Review fan selection for replacement review. |
12 | 40×40×20 | 15.12 | 52.31 | 0.84 | 7200 | 25.5 | |
![]() EEC0382B1-000U-A99 | SUNON 24VDC 9.2W 120x120x38mm DC Axial Fan for data center cooling EEC0382B1-000U-A99 is a 24 VDC axial fan for servers, data-communications equipment, control cabinets. Its main supplied feature is 48 dB noise data recorded for this model. It also lists a 120x120x38 mm size specified in the upload data. Review installation clearance for replacement review. |
24 | 120x120x38 | 234.5 | 89.7 | 9.2 | 3100 | 48 | |
PE60251B1-0000-A99 | SUNON 12VDC 3.57W 60×60×25mm DC Axial Fan for data center cooling PE60251B1-0000-A99 is a 12 VDC axial fan for servers, data-communications equipment, control cabinets. Its main supplied feature is 6900 rpm rated speed in the supplied parameter row. It also lists a 60×60×25 mm size specified in the upload data. Review wiring plan for replacement review. |
12 | 60×60×25 | 61.16 | 134.51 | 3.57 | 6900 | 44 | |
![]() MF40101VX-1000U-A99 | SUNON 12VDC 1.05W 40x40x10mm DC Axial Fan for data center cooling MF40101VX-1000U-A99 is a 12 VDC axial fan for servers, data-communications equipment, control cabinets. Its main supplied feature is 1.05 W input power for the listed electrical version. It also lists a 40*40*10 mm size specified in the upload data. Review system resistance for replacement review. |
12 | 40*40*10 | 16.83 | 62.3 | 1.05 | 8500 | 31.4 | |
![]() MF50100V1-1000U-A99 | SUNON 5VDC 0.82W 50x50x10mm DC Axial Fan for data center cooling MF50100V1-1000U-A99 is a 5 VDC axial fan for servers, data-communications equipment, control cabinets. Its main supplied feature is 5800 rpm rated speed in the supplied parameter row. It also lists a 50*50*10 mm size specified in the upload data. Review replacement fit for replacement review. |
5 | 50*50*10 | 13.8 | - | 0.82 | 5800 | 30.7 | |
![]() EE92252B1-000U-A99 | SUNON 24VDC 2.1W 92x92x25mm DC Axial Fan for data center cooling EE92252B1-000U-A99 is a 24 VDC axial fan for servers, data-communications equipment, control cabinets. Its main supplied feature is 87.55 m³/h maximum airflow stated for this model. It also lists a 92*92*25 mm size specified in the upload data. Review service access for replacement review. |
24 | 92*92*25 | 87.55 | 37.4 | 2.1 | 3000 | 34 | |
![]() EEC0382B3-000U-A99 | SUNON 24VDC 3.1W 120x120x38mm DC Axial Fan for data center cooling EEC0382B3-000U-A99 is a 24 VDC axial fan for servers, data-communications equipment, control cabinets. Its main supplied feature is 93 m³/h maximum airflow stated for this model. It also lists a 120*120*38 mm size specified in the upload data. Review duct connection for replacement review. |
24 | 120*120*38 | 93 | - | 3.1 | 2100 | 37 | |
![]() HA40101V4-000U-999 | SUNON 12VDC 0.38W 40x40x10mm DC Axial Fan for data center cooling HA40101V4-000U-999 is a 12 VDC axial fan for servers, data-communications equipment, control cabinets. Its main supplied feature is axial airflow intended for low-to-moderate system resistance. It also lists a 40x40x10mm mm size specified in the upload data. Review cooling margin for replacement review. |
12 | 40x40x10mm | 9.2 | 22.4 | 0.38 | 5000 | 15.7 | |
![]() HA40101V4-1000U-A99 | SUNON 12VDC 0.43W 40x40x10mm DC Axial Fan for data center cooling HA40101V4-1000U-A99 is a 12 VDC axial fan for servers, data-communications equipment, control cabinets. Its main supplied feature is axial airflow intended for low-to-moderate system resistance. It also lists a 40*40*10 mm size specified in the upload data. Review acoustic limit for replacement review. |
12 | 40*40*10 | 9.18 | - | 0.43 | 5000 | 15.7 | |
EG60070S1-C28U-S9A | SUNON 5VDC 1.96W DC Axial Fan for servers and data communications equipment Within servers, data-communications equipment, control cabinets, EG60070S1-C28U-S9A operates as a 5 VDC axial fan. Its representative supplied feature is 1.96 W input power for the listed electrical version. Selection focus: control method during replacement review. Check the exact variant before ordering. |
5 | - | - | - | 1.96 | - | - | |
![]() PFE0514B1-0000-S99 | SUNON 12V 22.56W 140x140x51mm 250.3m3/h DC Axial Fan for Industrial Cooling Specified at 12 VDC, PFE0514B1-0000-S99 is a SUNON DC axial fan for servers and data-center electronics in 140 × 140 × 51 mm dimensions. 1.43 Pa maximum pressure is the standout documented duty-point value. For system commissioning, start with the supplied rotational rating. Verify bearing and signal options in the exact datasheet. |
12 | 140x140x51 | 250.3 | 1.43 | 22.56 | 5000 | 61.4 | |
![]() XGE0384BX-Q011-S99 | SUNON 54V 243W 140x140x38mm 420m3/h DC Axial Fan for Industrial Cooling The XGE0384BX-Q011-S99 is SUNON's 54 VDC, 140 × 140 × 38 mm DC blower option for servers and data-center electronics. Up to 420 m³/h is its most prominent listed performance figure. Use the documented power demand when planning system commissioning. Verify bearing and signal options in the exact datasheet. |
54 | 140x140x38 | 420 | 11 | 243 | 14700 | 85 | |
![]() XGC0384BX-10000-S9H | SUNON 48V 100.8W 120x120x38mm 11600rpm DC Axial Fan for Industrial Cooling For thermal management in servers and data-center electronics, the XGC0384BX-10000-S9H provides a 48 VDC DC axial fan configuration measuring 120 × 120 × 38 mm. Up to 301.7 m³/h is its most prominent listed performance figure. Review its frame geometry during system commissioning. Verify bearing and signal options in the exact datasheet. |
48 | 120x120x38 | 301.7 | 5.58 | 100.8 | 11600 | 75 | |
![]() VF92381BX-D020-S9H | SUNON 12V 64.8W 92x92x38mm 171.7m3/h DC Axial Fan for Industrial Cooling SUNON VF92381BX-D020-S9H combines a 92 × 92 × 38 mm DC blower platform with a 12 VDC rating for servers and data-center electronics. 4.48 Pa maximum pressure is the standout documented duty-point value. Treat the cooling output as a primary input to system commissioning. Verify bearing and signal options in the exact datasheet. |
12 | 92x92x38 | 171.7 | 4.48 | 64.8 | 15400 | 74 | |
![]() PF92381BX-10000-S9H | SUNON 12V 50.4W 92x92x38mm 163.7m3/h 12000rpm DC Axial Fan for New Energy Sized for inverters, energy-storage systems, and charging equipment, SUNON PF92381BX-10000-S9H is a 12 VDC DC axial fan in a 92 × 92 × 38 mm frame. 2.4 Pa maximum pressure is the standout documented duty-point value. Base system commissioning on the stated operating point. Verify bearing and signal options in the exact datasheet. |
12 | 92x92x38 | 163.7 | 2.4 | 50.4 | 12000 | 70.2 | |
![]() XG80864BX-1Q01C-S9T | SUNON 54V 80x80x86mm 212.1m3/h DC Axial Fan for Industrial Cooling Within servers and data-center electronics, SUNON XG80864BX-1Q01C-S9T serves as a 80 × 80 × 86 mm DC blower operating at 54 VDC. Up to 212.1 m³/h is its most prominent listed performance figure. During system commissioning, compare the model's pressure capability. Verify bearing and signal options in the exact datasheet. |
54 | 80x80x86 | 212.1 | 11.05 | - | 17000/15000 | TBD | |
![]() VG80861BX-1Q07C-S9H | SUNON 12V 156W 80x80x86mm 202.5m3/h DC Axial Fan for Industrial Cooling Within servers and data-center electronics, VG80861BX-1Q07C-S9H provides a 80 × 80 × 86 mm, 12 VDC DC blower configuration. 156 W input is the defining electrical load in the supplied data. The recorded dimensional envelope should guide system commissioning. Verify bearing and signal options in the exact datasheet. |
12 | 80x80x86 | 202.5 | 10.18 | 156 | 17500/15200 | TBD | |
![]() VG80861BX-Q070-S9H | SUNON 12V 90W 80x80x86mm 161.7m3/h DC Axial Fan for Data Center Cooling The VG80861BX-Q070-S9H is SUNON's 12 VDC, 80 × 80 × 86 mm DC blower option for servers and data-center electronics. The supplied data list 81.1 dB, an important acoustic selection parameter. For system commissioning, start with the supplied acoustic value. Verify bearing and signal options in the exact datasheet. |
12 | 80x80x86 | 161.7 | 7.15 | 90 | 15700/14600 | 81.1 | |
![]() VF80864BX-1Q010-S9H | SUNON 54V 180.9W 80x80x86mm 218.4m3/h DC Axial Fan for Industrial Cooling VF80864BX-1Q010-S9H serves servers and data-center electronics as a 80 × 80 × 86 mm DC blower rated at 54 VDC. The supplied data list 87.3 dB, an important acoustic selection parameter. Use the documented electrical load when planning system commissioning. Verify bearing and signal options in the exact datasheet. |
54 | 80x80x86 | 218.4 | 8.82 | 180.9 | 17000/16000 | 87.3 | |
![]() VF80864BX-Q023-S9H | SUNON 54V 99.9W 80x80x86mm 166.3m3/h DC Axial Fan for Industrial Cooling SUNON VF80864BX-Q023-S9H combines a 80 × 80 × 86 mm DC blower platform with a 54 VDC rating for servers and data-center electronics. The supplied data list 81.9 dB, an important acoustic selection parameter. Review its speed benchmark during system commissioning. Verify bearing and signal options in the exact datasheet. |
54 | 80x80x86 | 166.3 | 7.22 | 99.9 | 16500/15700 | 81.9 |
The most reliable way to specify DC Fans is to work from the system, not from the catalog. Measure or calculate the airflow and pressure demand first, add the dimensional limits of the mounting position, and only then shortlist series whose curves cover your operating point with margin.
Electrical matching is the next gate. Confirm the supply voltage — 12 V, 24 V or 48 V DC for compact electronics cooling, 115 V or 230 V AC for equipment and panel cooling — and decide whether you need speed control. EC models accept PWM or 0-10 V signals and report speed through a tachometer output, which makes them the default choice for variable-airflow systems, while AC units remain a cost-effective answer for fixed-speed duty.
Then filter by environment. High ambient temperature, dust or moisture loads dictate the IP rating and bearing choice — ball bearings keep airflow and noise stable over years, while sleeve bearings suit light-duty horizontal mounting. Regulatory needs such as UL, CE and RoHS recognition should be confirmed before the shortlist goes to purchasing, together with a maximum allowed sound pressure level in dBA.
End the process by checking supply, not just specification: confirm current stock, the lead time for follow-up quantities, and obtain datasheets and dimension drawings so the mechanical interface is verified before the PO. Send us your airflow and pressure requirements and our engineers will confirm the best-matched series — 1,061 products are available in this category today.
The daily work of our sales engineers is built around DC Fans used in data center cooling, refrigeration and cold chain projects, building ventilation, telecom base stations, medical devices and industrial control cabinets — environments where a stopped fan is a stopped business process. That daily exposure to real installations is exactly what we bring back into every selection: not just reading curves, but knowing which models survive dust, heat, continuous duty and restricted service access.
A typical case: an equipment builder needed to replace an aging AC fan inside a control cabinet that could not be taken offline for more than an hour. By cross-referencing the frame dimensions, voltage and airflow curve, we supplied a current-series drop-in replacement with a matching tachometer signal, and the swap was completed during a scheduled maintenance window.
Refrigeration and cold chain customers bring us another pattern: the failed condenser fan is unavailable for weeks. Comparing diameter, speed, bearings and IP rating, we supply a functionally equivalent unit from stock so the system returns to duty the same week — the reason many service companies keep our contact number on file.
From one-piece emergency replacements to volume supply for equipment manufacturers, every SUNON enquiry is handled by the same rule: verify the parameters first, then quote — so what arrives on site is the fan the project actually needs.
Single-piece orders and samples are welcome — many customers validate one unit in their system before committing to volume. There is no minimum order quantity for standard stock models, and the sample price is deducted from the bulk order in most repeat purchases. Tell us the quantity you plan to use and we will quote both scenarios.
Yes. Beyond catalogue models we can discuss modified lead wires, connectors, speed curves, IP upgrades or private-label packaging for OEM projects. Customization usually starts from a defined annual quantity; our engineers will review your requirement and confirm feasibility, tooling cost and lead time before any commitment.
Every unit is covered by the manufacturer's warranty against defects in materials and workmanship, and we support you through the whole claim process so you deal with one supplier instead of chasing a factory overseas. If a failure appears in service, send us the serial number, operating conditions and photos, and we will arrange the replacement or credit path agreed in the quotation.
Bag
Bag packaging indicates that a specified quantity of product is packaged by the manufacturer in a bag, sealed pouch, or similar container and sold as a unit without repackaging. It is also used to describe kits/assortments where components are packaged in separate bags according to part number or parametric value, rather than in a compartmentalized box or similar rigid container.