EE92252B1-000U-A99 is a 24 VDC axial fan for servers, data-communications equipment, control cabinets. Its main supplied feature is 87.55 m³/h maximum airflow stated for this model. It also lists a 92*92*25 mm size specified in the upload data. Review service access for replacement review.
| Rated Voltage(V) | 24 |
|---|---|
| Size(mm) | 92*92*25 |
| Max.Air Flow(m³/h) | 87.55 |
| Max.Pressure(Pa) | 37.4 |
| Input Power(W) | 2.1 |
| Speed(rpm) | 3000 |
| Noise(db) | 34 |
The SUNON EE92252B1-000U-A99 contributes to data centers and communication application as a DC axial fan, combining a constrained-space forced-air cooling role with a clear mechanical and electrical integration path.
Listed moving air of 87.55 m3/h and pressure of 37.4 Pa provide starting points for duty-point evaluation in the completed application.
Air enters and leaves in the axial direction, supporting efficient exchange across open enclosures, electronics and ventilation paths.
Correct inlet clearance and discharge routing help preserve useful moving air while limiting avoidable recirculation and noise. Preserve the specified moving air direction during assembly. Review the approved electrical interface for the complete suffix.
Thermal management in servers and data-communication hardware can use SUNON EE92252B1-000U-A99 to cools computing and network assemblies. These systems operate with concentrated heat loads that can create local hot spots without continuous circulation.
For equipment in power supplies, inverters and control cabinets, SUNON EE92252B1-000U-A99 acts as a thermal control component that cools power modules and controls. The surrounding enclosure, filters and heat exchangers can add resistance that must be considered during selection.
In industrial automation machinery, the SUNON EE92252B1-000U-A99 provides forced temperature management flow that ventilates drives and production electronics. The machinery benefits from continuous heat removal where passive temperature management alone cannot maintain design margin.
SUNON supplies model EE92252B1-000U-A99 for medical and laboratory instruments, where directed air delivery cools enclosed instrument electronics. The completed design can connect measured thermal performance with a specific, repeatable fan configuration.
No exact IP protection level is stated for this item in the supplied sources. Confirm it before use in dusty, wet, or harsh locations.
The upload row lists 34 dB. Confirm the measurement condition and compare noise at the intended operating point.
No model-specific maintenance interval is supplied. Keep the airflow path clean, inspect mounting and electrical connections, and follow the exact product instructions.
The supplied sources do not confirm an integrated controller. Verify the exact electrical variant and control requirement before ordering.
Compare the full model suffix, voltage, size, motor or controller type, mounting, airflow, pressure, power, speed, and protection; do not copy data from a similar model.
The supplied application data covers servers, data-communications equipment, control cabinets. Confirm the installation's airflow, pressure, space, and electrical requirements.

For airflow duties across telecom cabinets, base stations, and network equipment, the EE80252BX-000U-A99 provides a 24 VDC DC blower configuration measuring 80 × 80 × 25 mm. Its 3600 rpm rating defines a lower-speed operating point. The recorded duty-point values should guide wiring review. Confirm environmental protection for the ordered version.
Read More
Within telecom cabinets, base stations, and network equipment, SUNON EE60252B1-000U-A99 serves as a 60 × 60 × 25 mm DC blower operating at 24 VDC. Its 39.9 m³/h airflow rating suits the stated equipment-cooling role. For wiring review, start with the supplied sound level. Confirm environmental protection for the ordered version.
Read More
Within telecom cabinets, base stations, and network equipment, SUNON EE92251BX-000U-A99 serves as a 92 × 92 × 25 mm DC blower operating at 12 VDC. Up to 93.4 m³/h is its most prominent listed performance figure. The recorded pressure capability should guide wiring review. Confirm environmental protection for the ordered version.
Read More
SUNON EE60251B3-000U-A99 combines a 60 × 60 × 25 mm DC blower platform with a 12 VDC rating for telecom cabinets, base stations, and network equipment. 19.9 Pa maximum pressure is the standout documented duty-point value. During controller selection, compare the model's dimensional envelope. Treat bearing and life data as suffix-specific.
Read More
The 60 × 60 × 25 mm EE60251B1-000U-A99 brings 12 VDC DC blower cooling to telecom cabinets, base stations, and network equipment. A listed input of 1.44 W is the model's notable electrical characteristic. Use the documented equipment fit when planning mounting verification. Validate mounting and wiring from the model drawing.
Read More
The EE80251B3-000U-A99 is SUNON's 12 VDC, 80 × 80 × 25 mm DC blower option for telecom cabinets, base stations, and network equipment. Its 2600 rpm rating defines a lower-speed operating point. Base mounting verification on the stated acoustic value. Validate mounting and wiring from the model drawing.
Read More