| Mfr Part # | Rated Voltage(V) | Size(mm) | Max.Air Flow(m³/h) | Max.Pressure(Pa) | Input Power(W) | Speed(rpm) | Noise(db) | |
|---|---|---|---|---|---|---|---|---|
![]() EEC0382B1-000U-F99 | SUNON 24VDC 9.2W 120x120x38mm DC Axial Fan for data center cooling EEC0382B1-000U-F99 is a 24 VDC axial fan for servers, data-communications equipment, control cabinets. Its main supplied feature is a 120*120*38 mm size specified in the upload data. It also lists 138 m³/h maximum airflow stated for this model. Review motor interface for site verification. |
24 | 120*120*38 | 138 | - | 9.2 | 3100 | 48 | |
![]() PMD2412PTB1-A(2).GN | SUNON 24VDC 11.8W 120×120×38mm DC Axial Fan for data center cooling PMD2412PTB1-A(2).GN is a 24 VDC axial fan for servers, data-communications equipment, control cabinets. Its main supplied feature is 254.85 m³/h maximum airflow stated for this model. It also lists a 120×120×38 mm size specified in the upload data. Review wiring plan for technical approval. |
24 | 120×120×38 | 254.85 | 154.44 | 11.8 | 4500 | 54 | |
![]() PF92252B1-1000U-A99 | SUNON 24VDC 4.92W DC Centrifugal Blower for data center cooling PF92252B1-1000U-A99 is a 24 VDC centrifugal fan for servers, medical equipment, laboratory equipment. Its main supplied feature is 127.5 m³/h maximum airflow stated for this model. It also lists a 92*92*25 mm size specified in the upload data. Review acoustic limit for technical approval. |
24 | 92*92*25 | 127.5 | - | 4.92 | 4500 | 46.1 | |
![]() EEC0252B1-000U-A99 | SUNON 24VDC 5W DC Axial Fan for servers and data communications equipment EEC0252B1-000U-A99 is a 24 VDC axial fan for servers, data-communications equipment, control cabinets. Its main supplied feature is axial airflow intended for low-to-moderate system resistance. It also lists a 120*120*25 mm size specified in the upload data. Review electrical supply for technical approval. |
24 | 120*120*25 | 108.2 | - | 5 | 3100 | 44.5 | |
![]() PMD2408PMB1-A (2).GN | SUNON 24VDC 9.6W 80x80x38mm DC Axial Fan for data center cooling PMD2408PMB1-A (2).GN is a 24 VDC axial fan for servers, data-communications equipment, control cabinets. Its main supplied feature is axial airflow intended for low-to-moderate system resistance. It also lists a 80*80*38 mm size specified in the upload data. Review housing geometry for retrofit assessment. |
24 | 80*80*38 | 84 | - | 9.6 | 5700 | 55.2 | |
![]() PMD2408PMB2-A.GN | SUNON 24VDC 7.2W DC Axial Fan for servers and data communications equipment PMD2408PMB2-A.GN is a 24 VDC axial fan for servers, data-communications equipment, control cabinets. Its main supplied feature is 51.6 dB noise data recorded for this model. It also lists a 80x80x38mm mm size specified in the upload data. Review performance curve for retrofit assessment. |
24 | 80x80x38mm | 126.6 | 142 | 7.2 | 4900 | 51.6 | |
![]() MF60252V1-1000U-A99 | SUNON 24VDC 1.25W 60x60x25mm DC Axial Fan for data center cooling MF60252V1-1000U-A99 is a 24 VDC axial fan for servers, data-communications equipment, control cabinets. Its main supplied feature is 27 dB noise data recorded for this model. It also lists a 60*60*25 mm size specified in the upload data. Review control method for maintenance planning. |
24 | 60*60*25 | 23.5 | - | 1.25 | 4500 | 27 | |
![]() MF92252V1-1000U-A99 | SUNON 24VDC 1.92W 92x92x25mm DC Axial Fan for data center cooling MF92252V1-1000U-A99 is a 24 VDC axial fan for servers, data-communications equipment, control cabinets. Its main supplied feature is 3000 rpm rated speed in the supplied parameter row. It also lists a 92*92*25 mm size specified in the upload data. Review electrical supply for maintenance planning. |
24 | 92*92*25 | 51.5 | - | 1.92 | 3000 | 34 | |
![]() MF40202VX-1000U-A99 | SUNON 24VDC DC Axial Fan for servers and data communications equipment MF40202VX-1000U-A99 is a 24 VDC axial fan for servers, data-communications equipment, control cabinets. Its main supplied feature is 18.36 m³/h maximum airflow stated for this model. It also lists a 40*40*20 mm size specified in the upload data. Review ventilation duty for installation planning. |
24 | 40*40*20 | 18.36 | - | - | 8000 | 27.5 | |
![]() MF50152V1-1000U-A99 | SUNON 24VDC 1.08W 50x50x15mm DC Axial Fan for data center cooling MF50152V1-1000U-A99 is a 24 VDC axial fan for servers, data-communications equipment, control cabinets. Its main supplied feature is 17 m³/h maximum airflow stated for this model. It also lists a 50*50*15 mm size specified in the upload data. Review electrical supply for installation planning. |
24 | 50*50*15 | 17 | - | 1.08 | 6100 | 33 | |
![]() MF50102V1-1Q01U-A99 | SUNON 24VDC 0.92W 50x50x10mm DC Axial Fan for data center cooling MF50102V1-1Q01U-A99 is a 24 VDC axial fan for servers, data-communications equipment, control cabinets. Its main supplied feature is a 50*50*10 mm size specified in the upload data. It also lists 0.92 W input power for the listed electrical version. Review controller compatibility for procurement comparison. |
24 | 50*50*10 | - | - | 0.92 | - | - | |
![]() MF60251V1-1000U-A99 | SUNON 12VDC 0.96W 60x60x25mm DC Axial Fan for data center cooling MF60251V1-1000U-A99 is a 12 VDC axial fan for servers, data-communications equipment, control cabinets. Its main supplied feature is 23.5 m³/h maximum airflow stated for this model. It also lists a 60*60*25 mm size specified in the upload data. Review control method for procurement comparison. |
12 | 60*60*25 | 23.5 | - | 0.96 | 4500 | 27 | |
![]() MF50101V1-1000U-A99 | SUNON 12VDC 0.84W 50x50x10mm DC Axial Fan for data center cooling MF50101V1-1000U-A99 is a 12 VDC axial fan for servers, data-communications equipment, control cabinets. Its main supplied feature is 30.7 dB noise data recorded for this model. It also lists a 50*50*10 mm size specified in the upload data. Review fan selection for system integration. Check the exact variant before ordering. |
12 | 50*50*10 | 13.8 | - | 0.84 | 5800 | 30.7 | |
![]() MF40102VX-1Q03C-A99 | SUNON 24VDC 1.92W 40x40x10mm DC Axial Fan for data center cooling MF40102VX-1Q03C-A99 is a 24 VDC axial fan for servers, data-communications equipment, control cabinets. Its main supplied feature is axial airflow intended for low-to-moderate system resistance. It also lists a 40x40x10 mm size specified in the upload data. Review replacement fit for system integration. |
24 | 40x40x10 | 18.7 | - | 1.92 | 10000 | 36.8 | |
MF40060V1-1000C-A99 | SUNON 5VDC 0.44W 40×40×6mm DC Axial Fan for data center cooling MF40060V1-1000C-A99 is a 5 VDC axial fan for servers, data-communications equipment, control cabinets. Its main supplied feature is 7000 rpm rated speed in the supplied parameter row. It also lists a 40×40×6 mm size specified in the upload data. Review controller compatibility for equipment design. |
5 | 40×40×6 | 10.7 | 24.91 | 0.44 | 7000 | 29.3 | |
![]() PMD2409PMB1-A.GN | SUNON 24VDC 12.2W DC Axial Fan for servers and data communications equipment PMD2409PMB1-A.GN is a 24 VDC axial fan for servers, data-communications equipment, control cabinets. Its main supplied feature is axial airflow intended for low-to-moderate system resistance. It also lists a 92x92x38mm mm size specified in the upload data. Review ventilation duty for equipment design. |
24 | 92x92x38mm | 204.2 | 176.9 | 12.2 | 4900 | 57.6 | |
MMF-06D24DM-AC5 | SUNON 24VDC 1.2W DC Axial Fan for servers and data communications equipment MMF-06D24DM-AC5 is a 24 VDC axial fan for servers, data-communications equipment, control cabinets. Its main supplied feature is a 60*60*25 mm size specified in the upload data. It also lists 1.2 W input power for the listed electrical version. Review wiring plan for equipment design. |
24 | 60*60*25 | - | - | 1.2 | 5400 | - | |
![]() MF80252V1-1000U-A99 | SUNON 24VDC 1.68W 80x80x25mm DC Axial Fan for data center cooling MF80252V1-1000U-A99 is a 24 VDC axial fan for servers, data-communications equipment, control cabinets. Its main supplied feature is axial airflow intended for low-to-moderate system resistance. It also lists a 80*80*25 mm size specified in the upload data. Review equipment interface for replacement review. |
24 | 80*80*25 | 41 | - | 1.68 | 3200 | 33 | |
PE60201B1-000U-A99 | SUNON 12VDC 2.3W 60×60×20mm DC Axial Fan for data center cooling PE60201B1-000U-A99 is a 12 VDC axial fan for servers, data-communications equipment, control cabinets. Its main supplied feature is 69.74 Pa maximum pressure stated for this model. It also lists a 60×60×20 mm size specified in the upload data. Review ventilation duty for replacement review. |
12 | 60×60×20 | 46.72 | 69.74 | 2.3 | 5000 | 39 | |
![]() PF97331B1-B00U-S99 | SUNON 12VDC 19.2W 97x97x33mm DC Centrifugal Blower for data center cooling PF97331B1-B00U-S99 is a 12 VDC centrifugal fan for servers, medical equipment, laboratory equipment. Its main supplied feature is 5400 rpm rated speed in the supplied parameter row. It also lists a 97x97x33mm mm size specified in the upload data. Review power budget for replacement review. |
12 | 97x97x33mm | 75.14 | 844.4 | 19.2 | 5400 | 58 |
The most reliable way to specify DC Fans is to work from the system, not from the catalog. Measure or calculate the airflow and pressure demand first, add the dimensional limits of the mounting position, and only then shortlist series whose curves cover your operating point with margin.
Electrical matching is the next gate. Confirm the supply voltage — 12 V, 24 V or 48 V DC for compact electronics cooling, 115 V or 230 V AC for equipment and panel cooling — and decide whether you need speed control. EC models accept PWM or 0-10 V signals and report speed through a tachometer output, which makes them the default choice for variable-airflow systems, while AC units remain a cost-effective answer for fixed-speed duty.
Then filter by environment. High ambient temperature, dust or moisture loads dictate the IP rating and bearing choice — ball bearings keep airflow and noise stable over years, while sleeve bearings suit light-duty horizontal mounting. Regulatory needs such as UL, CE and RoHS recognition should be confirmed before the shortlist goes to purchasing, together with a maximum allowed sound pressure level in dBA.
End the process by checking supply, not just specification: confirm current stock, the lead time for follow-up quantities, and obtain datasheets and dimension drawings so the mechanical interface is verified before the PO. Send us your airflow and pressure requirements and our engineers will confirm the best-matched series — 1,061 products are available in this category today.
The daily work of our sales engineers is built around DC Fans used in data center cooling, refrigeration and cold chain projects, building ventilation, telecom base stations, medical devices and industrial control cabinets — environments where a stopped fan is a stopped business process. That daily exposure to real installations is exactly what we bring back into every selection: not just reading curves, but knowing which models survive dust, heat, continuous duty and restricted service access.
A typical case: an equipment builder needed to replace an aging AC fan inside a control cabinet that could not be taken offline for more than an hour. By cross-referencing the frame dimensions, voltage and airflow curve, we supplied a current-series drop-in replacement with a matching tachometer signal, and the swap was completed during a scheduled maintenance window.
Refrigeration and cold chain customers bring us another pattern: the failed condenser fan is unavailable for weeks. Comparing diameter, speed, bearings and IP rating, we supply a functionally equivalent unit from stock so the system returns to duty the same week — the reason many service companies keep our contact number on file.
From one-piece emergency replacements to volume supply for equipment manufacturers, every SUNON enquiry is handled by the same rule: verify the parameters first, then quote — so what arrives on site is the fan the project actually needs.
Single-piece orders and samples are welcome — many customers validate one unit in their system before committing to volume. There is no minimum order quantity for standard stock models, and the sample price is deducted from the bulk order in most repeat purchases. Tell us the quantity you plan to use and we will quote both scenarios.
Yes. Beyond catalogue models we can discuss modified lead wires, connectors, speed curves, IP upgrades or private-label packaging for OEM projects. Customization usually starts from a defined annual quantity; our engineers will review your requirement and confirm feasibility, tooling cost and lead time before any commitment.
Every unit is covered by the manufacturer's warranty against defects in materials and workmanship, and we support you through the whole claim process so you deal with one supplier instead of chasing a factory overseas. If a failure appears in service, send us the serial number, operating conditions and photos, and we will arrange the replacement or credit path agreed in the quotation.
Bag
Bag packaging indicates that a specified quantity of product is packaged by the manufacturer in a bag, sealed pouch, or similar container and sold as a unit without repackaging. It is also used to describe kits/assortments where components are packaged in separate bags according to part number or parametric value, rather than in a compartmentalized box or similar rigid container.