PMD2412PTB1-A(2).GN is a 24 VDC axial fan for servers, data-communications equipment, control cabinets. Its main supplied feature is 254.85 m³/h maximum airflow stated for this model. It also lists a 120×120×38 mm size specified in the upload data. Review wiring plan for technical approval.
| Rated Voltage(V) | 24 |
|---|---|
| Size(mm) | 120×120×38 |
| Max.Air Flow(m³/h) | 254.85 |
| Max.Pressure(Pa) | 154.44 |
| Input Power(W) | 11.8 |
| Speed(rpm) | 4500 |
| Noise(db) | 54 |
PMD2412PTB1-A(2).GN gives designers of data centers and communication machinery a SUNON DC axial fan option for routing air through limited spaces and thermally active sections.
Listed airflow of 254.85 m3/h and pressure of 154.44 Pa provide starting points for duty-point evaluation in the completed unit.
A coordinated impeller, frame and motor path helps convert electrical input into useful thermal control airflow without unnecessary flow disturbance.
A documented machinery-level test links the selected fan to measurable thermal control value instead of isolated catalogue figures. Check environmental limits in the original product data. Confirm the exact operating point before production release. Preserve the specified airflow direction during assembly.
As part of servers and data-communication hardware, SUNON PMD2412PTB1-A(2).GN performs a defined thermal management task and cools computing and network assemblies. Consistent thermal management reduces thermal stress around assemblies that cycle between standby and high-load performance.
As part of power supplies, inverters and control cabinets, SUNON PMD2412PTB1-A(2).GN performs a defined thermal management task and cools power modules and controls. The result aids consistent service while keeping the thermal management function understandable for future service work.
The SUNON DC axial fan PMD2412PTB1-A(2).GN addresses thermal demand in industrial automation equipment by helping to ventilates drives and production electronics. Sustained performance requires an airflow component that integrates cleanly with the equipment architecture.
The PMD2412PTB1-A(2).GN is positioned for medical and laboratory instruments, helping the completed unit cools enclosed instrument electronics. Consistent temperature management reduces thermal stress around assemblies that cycle between standby and high-load performance.
The supplied application data covers servers, data-communications equipment, control cabinets. Confirm the installation's airflow, pressure, space, and electrical requirements.
Match the complete model code, voltage, dimensions, mounting arrangement, airflow direction, performance point, and control interface to the equipment.
The product is classified as a axial fan. Use the full model code because nearby variants can differ in motor, mounting, and controls.
The upload row lists 24 VDC. Confirm phase, frequency, terminals, and local supply conditions before wiring.
Check supply voltage, controller signals, blocked airflow, contamination, abnormal noise, rotation, and the equipment operating point before replacing the unit.
No model-specific maintenance interval is supplied. Keep the airflow path clean, inspect mounting and electrical connections, and follow the exact product instructions.
.GN-0.jpg)
PMD2408PMB1-A (2).GN is a 24 VDC axial fan for servers, data-communications equipment, control cabinets. Its main supplied feature is axial airflow intended for low-to-moderate system resistance. It also lists a 80*80*38 mm size specified in the upload data. Review housing geometry for retrofit assessment.
Read More.GN-0.webp)
Positioned for industrial electronics and equipment cooling, SUNON PMD2407PKB1-A.(2).GN is a 24 VDC DC blower in a 70 × 70 × 20 mm frame. 5 W input is the defining electrical load in the supplied data. During engineering comparison, compare the model's catalog specification. Confirm temperature and service-life limits from current data.
Read More
Within industrial electronics and equipment cooling, SUNON PMD2412PTB1-A serves as a 120 × 120 × 25 mm DC axial fan operating at 24 VDC. 11.8 W input is the defining electrical load in the supplied data. During engineering comparison, compare the model's sound level. Confirm temperature and service-life limits from current data.
Read More
Built for industrial electronics and equipment cooling, SUNON PMD2407PTB1-A uses a 70 × 70 × 25 mm DC blower arrangement at 24 VDC. 89.7 Pa maximum pressure is the standout documented duty-point value. Use the documented frame geometry when planning engineering comparison. Confirm temperature and service-life limits from current data.
Read More
Within industrial electronics and equipment cooling, PMD2408PTB1-A provides a 80 × 80 × 38 mm, 0 VDC DC blower configuration. Its 80 × 80 × 38 mm format is the main stated selection detail. During engineering comparison, compare the model's dimensional envelope. Confirm temperature and service-life limits from current data.
Read More.GN-0.webp)
Within industrial electronics and equipment cooling, SUNON PMD1209PMB1-A(2).GN serves as a 92 × 92 × 38 mm DC axial fan operating at 12 VDC. Up to 204.34 m³/h is its most prominent listed performance figure. For engineering comparison, start with the supplied rated dataset. Confirm temperature and service-life limits from current data.
Read More