PMD2408PMB2-A.GN is a 24 VDC axial fan for servers, data-communications equipment, control cabinets. Its main supplied feature is 51.6 dB noise data recorded for this model. It also lists a 80x80x38mm mm size specified in the upload data. Review performance curve for retrofit assessment.
| Rated Voltage(V) | 24 |
|---|---|
| Size(mm) | 80x80x38mm |
| Max.Air Flow(m³/h) | 126.6 |
| Max.Pressure(Pa) | 142 |
| Input Power(W) | 7.2 |
| Speed(rpm) | 4900 |
| Noise(db) | 51.6 |
Model PMD2408PMB2-A.GN is positioned as the SUNON DC axial fan for data centers and communication installation, supporting air delivery where passive convection cannot maintain the required temperature margin.
The stated 80x80x38mm mm size aids early mechanical-envelope and mounting checks.
The straight-through air delivery geometry simplifies integration into panels, cabinets and installation zones that need broad air exchange.
Installation designers gain a traceable thermal management specification that can be reviewed by engineering, purchasing and maintenance teams. Check environmental limits in the original product data. Confirm the exact operating point before production release. Preserve the specified air delivery direction during assembly.
When in-system in servers and data-communication hardware, PMD2408PMB2-A.GN cools computing and network assemblies within the available hardware space. The result reinforces controlled running while keeping the forced-air cooling function understandable for future service work.
As part of power supplies, inverters and control cabinets, SUNON PMD2408PMB2-A.GN performs a defined forced-air cooling task and cools power modules and controls. Sustained function requires an moving air component that integrates cleanly with the system architecture.
The PMD2408PMB2-A.GN is positioned for industrial automation hardware, helping the completed assembly ventilates drives and production electronics. Heat removal demand varies with workload, so the fan must be evaluated at the in-system operating point.
When production in medical and laboratory instruments, PMD2408PMB2-A.GN cools enclosed instrument electronics within the available assembly space. The result contributes to repeatable duty while keeping the cooling function understandable for future service work.
No model-specific maintenance interval is supplied. Keep the airflow path clean, inspect mounting and electrical connections, and follow the exact product instructions.
Its advantage should be judged from the matched series feature, exact size, electrical rating, and available performance data rather than from a generic fan comparison.
The supplied files do not establish a universal 24/7 duty rating. Validate ambient conditions, duty cycle, protection, and maintenance requirements for continuous use.
Check electrical supply, mounting clearance, fasteners, airflow direction, guards, wiring, and access for service before installation.
Confirm the target equipment, operating point, ambient conditions, installation space, electrical supply, controls, protection, quantity, and required delivery date.
The upload sheet marks the item as In Stock, but available quantity should be confirmed when the order is placed.

Specified at 24 VDC, PMD2412PMB1 is a SUNON DC axial fan for industrial electronics and equipment cooling in 120 × 120 × 38 mm dimensions. Up to 322.8 m³/h is its most prominent listed performance figure. The recorded rotational rating should guide engineering comparison. Confirm temperature and service-life limits from current data.
Read More.GN-0.jpg)
PMD2408PMB1-A (2).GN is a 24 VDC axial fan for servers, data-communications equipment, control cabinets. Its main supplied feature is axial airflow intended for low-to-moderate system resistance. It also lists a 80*80*38 mm size specified in the upload data. Review housing geometry for retrofit assessment.
Read More
Applied in industrial electronics and equipment cooling, SUNON PMD1209PMB2-A is a 12 VDC DC axial fan in a 92 × 92 × 38 mm frame. Up to 180.6 m³/h is its most prominent listed performance figure. The recorded selection parameters should guide engineering comparison. Confirm temperature and service-life limits from current data.
Read More.GN-0.webp)
Within industrial electronics and equipment cooling, SUNON PMD1209PMB1-A(2).GN serves as a 92 × 92 × 38 mm DC axial fan operating at 12 VDC. Up to 204.34 m³/h is its most prominent listed performance figure. For engineering comparison, start with the supplied rated dataset. Confirm temperature and service-life limits from current data.
Read More.GN-0.webp)
SUNON PMD2412PMB2-A(2).GN is a 24 VDC DC axial fan in a 120 × 120 × 38 mm format for industrial electronics and equipment cooling. Up to 288.8 m³/h is its most prominent listed performance figure. Use the documented motor input when planning engineering comparison. Confirm temperature and service-life limits from current data.
Read More
The 60 × 60 × 38 mm PMD2406PMB3-A.VDC brings 24 VDC DC blower cooling to industrial electronics and equipment cooling. 132 Pa maximum pressure is the standout documented duty-point value. Treat the equipment fit as a primary input to engineering comparison. Confirm temperature and service-life limits from current data.
Read More