MF80252V1-1000U-A99 is a 24 VDC axial fan for servers, data-communications equipment, control cabinets. Its main supplied feature is axial airflow intended for low-to-moderate system resistance. It also lists a 80*80*25 mm size specified in the upload data. Review equipment interface for replacement review.
| Rated Voltage(V) | 24 |
|---|---|
| Size(mm) | 80*80*25 |
| Max.Air Flow(m³/h) | 41 |
| Input Power(W) | 1.68 |
| Speed(rpm) | 3200 |
| Noise(db) | 33 |
SUNON developed MF80252V1-1000U-A99 in a DC axial fan configuration applicable to data centers and communication equipment, where consistent thermal management flow contributes to equipment availability.
A coordinated impeller, frame and motor path helps convert electrical input into useful thermal management thermal management flow without unnecessary flow disturbance.
The stated 80*80*25 mm size supports early mechanical-envelope and mounting checks.
For procurement teams, retaining the full model code supports controlled sourcing, compatible replacement and clearer maintenance records. Validate sound and temperature in the finished enclosure. Keep the model reference unchanged in replacement documentation. Check environmental limits in the original product data.
Servers and data-communication hardware require managed air movement, and SUNON MF80252V1-1000U-A99 cools computing and network assemblies. Consistent heat removal reduces thermal stress around assemblies that cycle between standby and high-load function.
The MF80252V1-1000U-A99 is positioned for power supplies, inverters and control cabinets, helping the completed assembly cools power modules and controls. This approach helps manufacturers balance cooling effectiveness, enclosure space and lifecycle maintenance.
For assembly in industrial automation assembly, SUNON MF80252V1-1000U-A99 acts as a heat removal component that ventilates drives and production electronics. The application value comes from predictable heat removal, controlled integration and verifiable replacement planning.
Thermal management in medical and laboratory instruments can use SUNON MF80252V1-1000U-A99 to cools enclosed instrument electronics. Temperature management flow must reach the intended heat source rather than bypassing it through unused gaps in the assembly.
The supplied row lists 41 m³/h airflow, 1.68 W input, 3200 rpm, 33 dB. Compare these values with the real system operating point, not only the free-air rating.
Compare the full model suffix, voltage, size, motor or controller type, mounting, airflow, pressure, power, speed, and protection; do not copy data from a similar model.
The supplied application data covers servers, data-communications equipment, control cabinets. Confirm the installation's airflow, pressure, space, and electrical requirements.
No quantified cost-saving claim is supplied for this exact item. Compare energy use, controls, service needs, and purchase cost using the required duty point.
The product is classified as a axial fan. Use the full model code because nearby variants can differ in motor, mounting, and controls.
Verify the listed size, mounting pattern, fan housing or nozzle arrangement, airflow direction, and service clearance against the equipment drawing.

Within telecom cabinets and network equipment, SUNON MF80152V1-1000U-A99 serves as a 80 × 80 × 15 mm DC axial fan operating at 24 VDC. Its 3500 rpm rating defines a lower-speed operating point. Review its thermal-duty record during maintenance preparation. Confirm temperature and service-life limits from current data.
Read More
SUNON MF40102V2-Q00U-A99 is a 24 VDC DC blower in a 40 × 40 × 10 mm format for telecom cabinets and network equipment. Its 11.9 m³/h airflow rating suits the stated equipment-cooling role. Base maintenance preparation on the stated motor input. Confirm temperature and service-life limits from current data.
Read More
The MF50151VX-1000U-A99 is SUNON's 12 VDC, 50 × 50 × 15 mm DC blower option for telecom cabinets and network equipment. 7200 rpm is the model's most distinctive operating parameter. During airflow-path design, compare the model's airflow profile. Obtain the applicable curve before final duty-point approval.
Read More
SUNON MF80151V3-1000U-A99 combines a 80 × 80 × 15 mm DC axial fan platform with a 12 VDC rating for telecom cabinets and network equipment. Its 2800 rpm rating defines a lower-speed operating point. For acoustic assessment, start with the supplied technical profile. Match the exact part number before approving a substitute.
Read More
The MF30060V2-10000-A99 is SUNON's 5 VDC, 30 × 30 × 6 mm DC axial fan option for telecom cabinets and network equipment. A listed input of 0.36 W is the model's notable electrical characteristic. Use the documented operating point when planning compatibility checking. Reconcile the model code with the required electrical interface.
Read More
SUNON configures MF30060V1-10000-A99 as a 30 × 30 × 6 mm DC axial fan for telecom cabinets and network equipment, operating at 5 VDC. Its 8.3 m³/h airflow rating suits the stated equipment-cooling role. Review its pressure capability during compatibility checking. Reconcile the model code with the required electrical interface.
Read More