| Mfr Part # | Rated Voltage(V) | Size(mm) | Max.Air Flow(m³/h) | Max.Pressure(Pa) | Input Power(W) | Speed(rpm) | Noise(db) | |
|---|---|---|---|---|---|---|---|---|
![]() XF40281BX-Q032-S9H | SUNON 12V 28.2W 40x40x28mm 38.6m3/h DC Axial Fan for Data Center Cooling Applied in servers and data-center electronics, SUNON XF40281BX-Q032-S9H is a 12 VDC DC blower in a 40 × 40 × 28 mm frame. 33000 rpm is the model's most distinctive operating parameter. For application screening, start with the supplied operating point. Validate approvals and protection at complete-part-number level. |
12 | 40x40x28 | 38.6 | 5.83 | 28.2 | 33000 | 70.1 | |
![]() XF40281BX-Q014-S9H | SUNON 12V 18W 40x40x28mm 31m3/h DC Axial Fan for Data Center Cooling Within servers and data-center electronics, SUNON XF40281BX-Q014-S9H serves as a 40 × 40 × 28 mm DC blower operating at 12 VDC. 36000 rpm is the model's most distinctive operating parameter. Use the documented pressure capability when planning application screening. Validate approvals and protection at complete-part-number level. |
12 | 40x40x28 | 31 | 6.8 | 18 | 36000 | 68.7 | |
![]() XF40281BX-10000-S9T | SUNON 12V 28.8W 40x40x28mm 39.3m3/h DC Axial Fan for Industrial Cooling Within servers and data-center electronics, XF40281BX-10000-S9T provides a 40 × 40 × 28 mm, 12 VDC DC blower configuration. 33000 rpm is the model's most distinctive operating parameter. Review its dimensional envelope during application screening. Validate approvals and protection at complete-part-number level. |
12 | 40x40x28 | 39.3 | 6.39 | 28.8 | 33000 | 71.8 | |
![]() VF40281BX-1Q010-S9H | SUNON 12V 22.8W 40x40x28mm 36.9m3/h DC Axial Fan for Industrial Cooling The VF40281BX-1Q010-S9H is SUNON's 12 VDC, 40 × 40 × 28 mm DC axial fan option for servers and data-center electronics. 27000 rpm is the model's most distinctive operating parameter. Treat the acoustic value as a primary input to application screening. Validate approvals and protection at complete-part-number level. |
12 | 40x40x28 | 36.9 | 4.48 | 22.8 | 27000 | 64.1 | |
![]() VF40281BX-Q09U-S9H | SUNON 12V 17.04W 40x40x28mm 32.5m3/h DC Axial Fan for Industrial Cooling For thermal management in servers and data-center electronics, the VF40281BX-Q09U-S9H provides a 12 VDC DC axial fan configuration measuring 40 × 40 × 28 mm. 28600 rpm is the model's most distinctive operating parameter. Base application screening on the stated electrical load. Validate approvals and protection at complete-part-number level. |
12 | 40x40x28 | 32.5 | 4.17 | 17.04 | 28600 | 63.8 | |
![]() PF40281BX-D089-S99 | SUNON 12V 13.8W 40x40x28mm 31.6m3/h DC Axial Fan for Data Center Cooling SUNON PF40281BX-D089-S99 combines a 40 × 40 × 28 mm DC axial fan platform with a 12 VDC rating for servers and data-center electronics. 3.25 Pa maximum pressure is the standout documented duty-point value. During application screening, compare the model's speed benchmark. Validate approvals and protection at complete-part-number level. |
12 | 40x40x28 | 31.6 | 3.25 | 13.8 | 23000 | 69.1 | |
![]() PF40281BX-10000-S9H | SUNON 12V 11.4W 40x40x28mm 31.3m3/h 22000rpm DC Axial Fan for New Energy SUNON PF40281BX-10000-S9H is a 12 VDC DC axial fan in a 40 × 40 × 28 mm format for inverters, energy-storage systems, and charging equipment. 3.12 Pa maximum pressure is the standout documented duty-point value. The recorded airflow profile should guide application screening. Validate approvals and protection at complete-part-number level. |
12 | 40x40x28 | 31.3 | 3.12 | 11.4 | 22000 | 62 | |
![]() VF60384BX-10000-A9H | SUNON 48V 22.08W 60x60x38mm 115.2m3/h DC Axial Fan for Data Center Cooling SUNON VF60384BX-10000-A9H combines a 60 × 60 × 38 mm DC axial fan platform with a 48 VDC rating for servers and data-center electronics. 1205.6 Pa maximum pressure is the standout documented duty-point value. Treat the motor input as a primary input to project documentation. Reconcile the model code with the required electrical interface. |
48 | 60x60x38mm | 115.2 | 1205.6 | 22.08 | 22800 | 64.1 | |
![]() VF60384B1-10000-A9H | SUNON 48V 12.72W 60x60x38mm 91.9m3/h DC Axial Fan for Data Center Cooling Configured for servers and data-center electronics, SUNON VF60384B1-10000-A9H is a 48 VDC DC axial fan in a 60 × 60 × 38 mm frame. 1053.7 Pa maximum pressure is the standout documented duty-point value. Base project documentation on the stated ventilation capacity. Reconcile the model code with the required electrical interface. |
48 | 60x60x38mm | 91.9 | 1053.7 | 12.72 | 18300 | 60.9 | |
![]() VF60381BX-0000-A9H | SUNON 12V 22.8W 60x60x38mm 115.2m3/h DC Axial Fan for Data Center Cooling Within servers and data-center electronics, SUNON VF60381BX-0000-A9H serves as a 60 × 60 × 38 mm DC axial fan operating at 12 VDC. 1205.6 Pa maximum pressure is the standout documented duty-point value. During project documentation, compare the model's equipment fit. Reconcile the model code with the required electrical interface. |
12 | 60x60x38mm | 115.2 | 1205.6 | 22.8 | 22800 | 64.1 | |
![]() VF60381B1-0000-A9H | SUNON 12V 12W 60x60x38mm 91.9m3/h DC Axial Fan for Data Center Cooling Built for servers and data-center electronics, SUNON VF60381B1-0000-A9H uses a 60 × 60 × 38 mm DC axial fan arrangement at 12 VDC. 1053.7 Pa maximum pressure is the standout documented duty-point value. The recorded suffix definition should guide project documentation. Reconcile the model code with the required electrical interface. |
12 | 60x60x38mm | 91.9 | 1053.7 | 12 | 18300 | 60.9 | |
![]() VF40281BX-0000-A9H | SUNON 12V 13.68W 40x40x28mm 53.5m3/h DC Axial Fan for Data Center Cooling The VF40281BX-0000-A9H is SUNON's 12 VDC, 40 × 40 × 28 mm DC axial fan option for servers and data-center electronics. 27000 rpm is the model's most distinctive operating parameter. For project documentation, start with the supplied catalog specification. Reconcile the model code with the required electrical interface. |
12 | 40x40x28mm | 53.5 | 983.9 | 13.68 | 27000 | 63.7 | |
![]() VF40281B1-0000-A9H | SUNON 12V 7.56W 40x40x28mm 43.5m3/h DC Axial Fan for Data Center Cooling A 40 × 40 × 28 mm frame and 12 VDC rating define VF40281B1-0000-A9H, a DC axial fan for servers and data-center electronics. 21600 rpm is the model's most distinctive operating parameter. Use the documented thermal-duty record when planning project documentation. Reconcile the model code with the required electrical interface. |
12 | 40x40x28mm | 43.5 | 690 | 7.56 | 21600 | 58.6 | |
![]() VF38561BX-10000-A9T | SUNON 12V 14.4W 38x38x56mm 53m3/h DC Axial Fan for Data Center Cooling SUNON VF38561BX-10000-A9T combines a 38 × 38 × 56 mm DC axial fan platform with a 12 VDC rating for servers and data-center electronics. 29300 rpm is the model's most distinctive operating parameter. Review its performance curve during project documentation. Reconcile the model code with the required electrical interface. |
12 | 38x38x56mm | 53 | 1145.8 | 14.4 | 29300 | 61.6 | |
![]() VF38281BX-0000-A9H | SUNON 12V 10.44W 38x38x28mm 41.1m3/h DC Axial Fan for Data Center Cooling Engineered for servers and data-center electronics, SUNON VF38281BX-0000-A9H is a 12 VDC DC axial fan in a 38 × 38 × 28 mm frame. 27000 rpm is the model's most distinctive operating parameter. Treat the mounting size as a primary input to project documentation. Reconcile the model code with the required electrical interface. |
12 | 38x38x28mm | 41.1 | 886.8 | 10.44 | 27000 | 61.6 | |
![]() VF38281B1-0000-A9H | SUNON 12V 5.7W 38x38x28mm 32.1m3/h DC Axial Fan for Data Center Cooling Within servers and data-center electronics, SUNON VF38281B1-0000-A9H serves as a 38 × 38 × 28 mm DC axial fan operating at 12 VDC. 21600 rpm is the model's most distinctive operating parameter. Base project documentation on the stated supply requirement. Reconcile the model code with the required electrical interface. |
12 | 38x38x28mm | 32.1 | 622.7 | 5.7 | 21600 | 58.1 | |
![]() VF60381BX-Q08U-Q9I | SUNON 12V 22.8W 60x60x38mm 115.2m3/h DC Axial Fan for Industrial Cooling VF60381BX-Q08U-Q9I serves servers and data-center electronics as a 60 × 60 × 38 mm DC axial fan rated at 12 VDC. 1205.6 Pa maximum pressure is the standout documented duty-point value. During project documentation, compare the model's static-pressure entry. Reconcile the model code with the required electrical interface. |
12 | 60x60x38mm | 115.2 | 1205.6 | 22.8 | 22800 | 64.1 | |
![]() VF60381BX-Q090-S9H | SUNON 12V 22.8W 60x60x38mm 115.2m3/h DC Axial Fan for Data Center Cooling The VF60381BX-Q090-S9H is SUNON's 12 VDC, 60 × 60 × 38 mm DC axial fan option for servers and data-center electronics. 1205.6 Pa maximum pressure is the standout documented duty-point value. The recorded volume-flow figure should guide project documentation. Reconcile the model code with the required electrical interface. |
12 | 60x60x38mm | 115.2 | 1205.6 | 22.8 | 22800 | 64.1 | |
![]() VF80381B1-1Q04U-S9H | SUNON 12V 33.12W 80x80x38mm 125.2m3/h DC Axial Fan for Data Center Cooling SUNON VF80381B1-1Q04U-S9H is a 12 VDC DC blower in a 80 × 80 × 38 mm format for servers and data-center electronics. 1.84 Pa maximum pressure is the standout documented duty-point value. For project documentation, start with the supplied sound level. Reconcile the model code with the required electrical interface. |
12 | 80x80x38 | 125.2 | 1.84 | 33.12 | 10800 | 60.6 | |
![]() XG40561BX-1Q310-S9H | SUNON 40x40x56mm DC Axial Fan for Data Center Cooling SUNON XG40561BX-1Q310-S9H combines a 40 × 40 × 56 mm DC blower platform with a 0 VDC rating for servers and data-center electronics. Its 40 × 40 × 56 mm format is the main stated selection detail. Use the documented rotational rating when planning project documentation. Reconcile the model code with the required electrical interface. |
0 | 40x40x56 | - | - | - | - | - |
The most reliable way to specify DC Fans is to work from the system, not from the catalog. Measure or calculate the airflow and pressure demand first, add the dimensional limits of the mounting position, and only then shortlist series whose curves cover your operating point with margin.
Electrical matching is the next gate. Confirm the supply voltage — 12 V, 24 V or 48 V DC for compact electronics cooling, 115 V or 230 V AC for equipment and panel cooling — and decide whether you need speed control. EC models accept PWM or 0-10 V signals and report speed through a tachometer output, which makes them the default choice for variable-airflow systems, while AC units remain a cost-effective answer for fixed-speed duty.
Then filter by environment. High ambient temperature, dust or moisture loads dictate the IP rating and bearing choice — ball bearings keep airflow and noise stable over years, while sleeve bearings suit light-duty horizontal mounting. Regulatory needs such as UL, CE and RoHS recognition should be confirmed before the shortlist goes to purchasing, together with a maximum allowed sound pressure level in dBA.
End the process by checking supply, not just specification: confirm current stock, the lead time for follow-up quantities, and obtain datasheets and dimension drawings so the mechanical interface is verified before the PO. Send us your airflow and pressure requirements and our engineers will confirm the best-matched series — 1,061 products are available in this category today.
The daily work of our sales engineers is built around DC Fans used in data center cooling, refrigeration and cold chain projects, building ventilation, telecom base stations, medical devices and industrial control cabinets — environments where a stopped fan is a stopped business process. That daily exposure to real installations is exactly what we bring back into every selection: not just reading curves, but knowing which models survive dust, heat, continuous duty and restricted service access.
A typical case: an equipment builder needed to replace an aging AC fan inside a control cabinet that could not be taken offline for more than an hour. By cross-referencing the frame dimensions, voltage and airflow curve, we supplied a current-series drop-in replacement with a matching tachometer signal, and the swap was completed during a scheduled maintenance window.
Refrigeration and cold chain customers bring us another pattern: the failed condenser fan is unavailable for weeks. Comparing diameter, speed, bearings and IP rating, we supply a functionally equivalent unit from stock so the system returns to duty the same week — the reason many service companies keep our contact number on file.
From one-piece emergency replacements to volume supply for equipment manufacturers, every SUNON enquiry is handled by the same rule: verify the parameters first, then quote — so what arrives on site is the fan the project actually needs.
Single-piece orders and samples are welcome — many customers validate one unit in their system before committing to volume. There is no minimum order quantity for standard stock models, and the sample price is deducted from the bulk order in most repeat purchases. Tell us the quantity you plan to use and we will quote both scenarios.
Yes. Beyond catalogue models we can discuss modified lead wires, connectors, speed curves, IP upgrades or private-label packaging for OEM projects. Customization usually starts from a defined annual quantity; our engineers will review your requirement and confirm feasibility, tooling cost and lead time before any commitment.
Every unit is covered by the manufacturer's warranty against defects in materials and workmanship, and we support you through the whole claim process so you deal with one supplier instead of chasing a factory overseas. If a failure appears in service, send us the serial number, operating conditions and photos, and we will arrange the replacement or credit path agreed in the quotation.
Bag
Bag packaging indicates that a specified quantity of product is packaged by the manufacturer in a bag, sealed pouch, or similar container and sold as a unit without repackaging. It is also used to describe kits/assortments where components are packaged in separate bags according to part number or parametric value, rather than in a compartmentalized box or similar rigid container.