| Mfr Part # | Rated Voltage(V) | Size(mm) | Max.Air Flow(m³/h) | Max.Pressure(Pa) | Input Power(W) | Speed(rpm) | Noise(db) | |
|---|---|---|---|---|---|---|---|---|
![]() XG80804BX-1Q010-S9T | SUNON 54V 129.6W 80x80x80mm 193.5m3/h DC Axial Fan for Industrial Cooling Designed for servers and data-center electronics, SUNON XG80804BX-1Q010-S9T is a 54 VDC DC blower in a 80 × 80 × 80 mm frame. The supplied data list 85.4 dB, an important acoustic selection parameter. Treat the airflow profile as a primary input to system commissioning. Verify bearing and signal options in the exact datasheet. |
54 | 80x80x80 | 193.5 | 9.27 | 129.6 | 16200/14200 | 85.4 | |
![]() XG80804BX-1Q110-S9T | SUNON 54V 80x80x80mm 211.8m3/h DC Axial Fan for Industrial Cooling Within servers and data-center electronics, SUNON XG80804BX-1Q110-S9T serves as a 80 × 80 × 80 mm DC blower operating at 54 VDC. The supplied data list 87.6 dB, an important acoustic selection parameter. Base technical purchasing on the stated application data. Request the exact performance curve for final engineering signoff. |
54 | 80x80x80 | 211.8 | 11.53 | - | 17500/15500 | 87.6 | |
![]() XG80804BX-1Q080-S9T | SUNON 54V 80x80x80mm 204.2m3/h DC Axial Fan for Industrial Cooling The 80 × 80 × 80 mm XG80804BX-1Q080-S9T brings 54 VDC DC blower cooling to servers and data-center electronics. The supplied data list 86 dB, an important acoustic selection parameter. During technical purchasing, compare the model's technical profile. Request the exact performance curve for final engineering signoff. |
54 | 80x80x80 | 204.2 | 10.63 | - | 17500/15500 | 86 | |
![]() XG80804BX-1Q013-S9W | SUNON 54V 80x80x80mm 201.7m3/h DC Axial Fan for Industrial Cooling The XG80804BX-1Q013-S9W is SUNON's 54 VDC, 80 × 80 × 80 mm DC blower option for servers and data-center electronics. The supplied data list 86 dB, an important acoustic selection parameter. The recorded model record should guide technical purchasing. Request the exact performance curve for final engineering signoff. |
54 | 80x80x80 | 201.7 | 10.26 | - | 16500/15500 | 86 | |
![]() XG80801BX-1Q023-S9T | SUNON 12V 80x80x80mm 191.8m3/h DC Axial Fan for Industrial Cooling XG80801BX-1Q023-S9T addresses servers and data-center electronics through a 12 VDC DC blower platform measuring 80 × 80 × 80 mm. The supplied data list 85.2 dB, an important acoustic selection parameter. For technical purchasing, start with the supplied product configuration. Request the exact performance curve for final engineering signoff. |
12 | 80x80x80 | 191.8 | 8.59 | - | 15800/14200 | 85.2 | |
![]() XG80801BX-1Q061-S9T | SUNON 12V 80x80x80mm 203.2m3/h DC Axial Fan for Industrial Cooling SUNON XG80801BX-1Q061-S9T combines a 80 × 80 × 80 mm DC blower platform with a 12 VDC rating for servers and data-center electronics. Up to 203.2 m³/h is its most prominent listed performance figure. Use the documented system interface when planning technical purchasing. Request the exact performance curve for final engineering signoff. |
12 | 80x80x80 | 203.2 | 10.44 | - | 16500/15500 | TBC | |
![]() XG80801BX-1Q110-S9T | SUNON 12V 80x80x80mm 199.89m3/h DC Axial Fan for Industrial Cooling Used in servers and data-center electronics, SUNON XG80801BX-1Q110-S9T is a 12 VDC DC blower in a 80 × 80 × 80 mm frame. Up to 199.89 m³/h is its most prominent listed performance figure. Review its cooling specification during technical purchasing. Request the exact performance curve for final engineering signoff. |
12 | 80x80x80 | 199.89 | 10.93 | - | 17700/16200 | TBC | |
![]() XG80801BX-1Q030-S9T | SUNON 12V 126W 80x80x80mm 187.7m3/h DC Axial Fan for Industrial Cooling Within servers and data-center electronics, SUNON XG80801BX-1Q030-S9T serves as a 80 × 80 × 80 mm DC blower operating at 12 VDC. The supplied data list 83.4 dB, an important acoustic selection parameter. Treat the duty-point values as a primary input to technical purchasing. Request the exact performance curve for final engineering signoff. |
12 | 80x80x80 | 187.7 | 8.53 | 126 | 15800/13600 | 83.4 | |
![]() VG80801BX-1Q014-S9H | SUNON 12V 128.4W 80x80x80mm 201.9m3/h DC Axial Fan for Data Center Cooling The 12 VDC SUNON VG80801BX-1Q014-S9H is a DC blower sized 80 × 80 × 80 mm for servers and data-center electronics. The supplied data list 80.5 dB, an important acoustic selection parameter. Base technical purchasing on the stated installation footprint. Request the exact performance curve for final engineering signoff. |
12 | 80x80x80 | 201.9 | 7.4 | 128.4 | 16500/13500 | 80.5 | |
![]() VF80804BX-1Q040-S9H | SUNON 54V 148.5W 80x80x80mm 211.2m3/h DC Axial Fan for Industrial Cooling The VF80804BX-1Q040-S9H is SUNON's 54 VDC, 80 × 80 × 80 mm DC blower option for servers and data-center electronics. The supplied data list 84.6 dB, an important acoustic selection parameter. During technical purchasing, compare the model's selection parameters. Request the exact performance curve for final engineering signoff. |
54 | 80x80x80 | 211.2 | 7.37 | 148.5 | 17000/14600 | 84.6 | |
![]() VF80801BX-Q031-S9H | SUNON 12V 112.8W 80x80x80mm 168.6m3/h DC Axial Fan for Industrial Cooling For servers and data-center electronics, VF80801BX-Q031-S9H combines 12 VDC operation with a 80 × 80 × 80 mm DC blower design. The supplied data list 80 dB, an important acoustic selection parameter. The recorded rated dataset should guide technical purchasing. Request the exact performance curve for final engineering signoff. |
12 | 80x80x80 | 168.6 | 6.9 | 112.8 | 15400/13600 | 80 | |
![]() PF80801BX-0000-S9H | SUNON 12V 81.6W 80x80x80mm 151.5m3/h DC Axial Fan for Data Center Cooling SUNON PF80801BX-0000-S9H combines a 80 × 80 × 80 mm DC axial fan platform with a 12 VDC rating for servers and data-center electronics. The supplied data list 80.4 dB, an important acoustic selection parameter. For technical purchasing, start with the supplied motor input. Request the exact performance curve for final engineering signoff. |
12 | 80x80x80 | 151.5 | 5.44 | 81.6 | 15600/14100 | 80.4 | |
![]() VF80761BX-Q040-S9H | SUNON 12V 68.6W 80x80x76mm 132.48m3/h DC Axial Fan for Industrial Cooling Applied in servers and data-center electronics, SUNON VF80761BX-Q040-S9H is a 12 VDC DC blower in a 80 × 80 × 76 mm frame. The supplied data list 78.8 dB, an important acoustic selection parameter. Use the documented ventilation capacity when planning technical purchasing. Request the exact performance curve for final engineering signoff. |
12 | 80x80x76 | 132.48 | 10.98 | 68.6 | 17000/17000 | 78.8 | |
![]() XG80564BX-1Q010-S9W | SUNON 51V 102W 80x80x56mm 169.6m3/h DC Axial Fan for Industrial Cooling Within servers and data-center electronics, SUNON XG80564BX-1Q010-S9W serves as a 80 × 80 × 56 mm DC blower operating at 51 VDC. The supplied data list 87.2 dB, an important acoustic selection parameter. Review its equipment fit during technical purchasing. Request the exact performance curve for final engineering signoff. |
51 | 80x80x56 | 169.6 | 9.49 | 102 | 18500/16000 | 87.2 | |
![]() XG80561BX-1Q010-S9T | SUNON 12V 80x80x56mm 155.8m3/h DC Axial Fan for Industrial Cooling Built for servers and data-center electronics, SUNON XG80561BX-1Q010-S9T uses a 80 × 80 × 56 mm DC blower arrangement at 12 VDC. The supplied data list 83.8 dB, an important acoustic selection parameter. Treat the suffix definition as a primary input to technical purchasing. Request the exact performance curve for final engineering signoff. |
12 | 80x80x56 | 155.8 | 10.53 | - | 17500/16000 | 83.8 | |
![]() XG80561BX-1Q1XX-S9W | SUNON 12V 80x80x56mm 174.7m3/h DC Axial Fan for Industrial Cooling The XG80561BX-1Q1XX-S9W is SUNON's 12 VDC, 80 × 80 × 56 mm DC blower option for servers and data-center electronics. 9.96 Pa maximum pressure is the standout documented duty-point value. Base technical purchasing on the stated catalog specification. Request the exact performance curve for final engineering signoff. |
12 | 80x80x56 | 174.7 | 9.96 | - | 19000/16000 | TBC | |
![]() XG80561BX-1Q03C-S9T | SUNON 12V 80x80x56mm 163.5m3/h DC Axial Fan for Industrial Cooling A 80 × 80 × 56 mm frame and 12 VDC rating define XG80561BX-1Q03C-S9T, a DC blower for servers and data-center electronics. 9.68 Pa maximum pressure is the standout documented duty-point value. During technical purchasing, compare the model's thermal-duty record. Request the exact performance curve for final engineering signoff. |
12 | 80x80x56 | 163.5 | 9.68 | - | 18300/15700 | TBC | |
![]() VG80561BX-1Q065-S9H | SUNON 12V 80x80x56mm 139m3/h DC Axial Fan for Industrial Cooling SUNON VG80561BX-1Q065-S9H combines a 80 × 80 × 56 mm DC blower platform with a 12 VDC rating for servers and data-center electronics. The supplied data list 78.6 dB, an important acoustic selection parameter. The recorded performance curve should guide technical purchasing. Request the exact performance curve for final engineering signoff. |
12 | 80x80x56 | 139 | 9.57 | - | 18000/15400 | 78.6 | |
![]() VG80561BX-Q140-S9H | SUNON 12V 48W 80x80x56mm 130.4m3/h DC Axial Fan for Data Center Cooling Positioned for servers and data-center electronics, SUNON VG80561BX-Q140-S9H is a 12 VDC DC blower in a 80 × 80 × 56 mm frame. The supplied data list 77.3 dB, an important acoustic selection parameter. For technical purchasing, start with the supplied mounting size. Request the exact performance curve for final engineering signoff. |
12 | 80x80x56 | 130.4 | 8.41 | 48 | 17000/14500 | 77.3 | |
![]() VF80561BX-Q11C-S9H | SUNON 12V 26.4W 80x80x56mm 94.8m3/h DC Axial Fan for Industrial Cooling Within servers and data-center electronics, SUNON VF80561BX-Q11C-S9H serves as a 80 × 80 × 56 mm DC blower operating at 12 VDC. 3.57 Pa maximum pressure is the standout documented duty-point value. Use the documented supply requirement when planning technical purchasing. Request the exact performance curve for final engineering signoff. |
12 | 80x80x56 | 94.8 | 3.57 | 26.4 | 12700/10900 | 70.8 |
The most reliable way to specify DC Fans is to work from the system, not from the catalog. Measure or calculate the airflow and pressure demand first, add the dimensional limits of the mounting position, and only then shortlist series whose curves cover your operating point with margin.
Electrical matching is the next gate. Confirm the supply voltage — 12 V, 24 V or 48 V DC for compact electronics cooling, 115 V or 230 V AC for equipment and panel cooling — and decide whether you need speed control. EC models accept PWM or 0-10 V signals and report speed through a tachometer output, which makes them the default choice for variable-airflow systems, while AC units remain a cost-effective answer for fixed-speed duty.
Then filter by environment. High ambient temperature, dust or moisture loads dictate the IP rating and bearing choice — ball bearings keep airflow and noise stable over years, while sleeve bearings suit light-duty horizontal mounting. Regulatory needs such as UL, CE and RoHS recognition should be confirmed before the shortlist goes to purchasing, together with a maximum allowed sound pressure level in dBA.
End the process by checking supply, not just specification: confirm current stock, the lead time for follow-up quantities, and obtain datasheets and dimension drawings so the mechanical interface is verified before the PO. Send us your airflow and pressure requirements and our engineers will confirm the best-matched series — 1,061 products are available in this category today.
The daily work of our sales engineers is built around DC Fans used in data center cooling, refrigeration and cold chain projects, building ventilation, telecom base stations, medical devices and industrial control cabinets — environments where a stopped fan is a stopped business process. That daily exposure to real installations is exactly what we bring back into every selection: not just reading curves, but knowing which models survive dust, heat, continuous duty and restricted service access.
A typical case: an equipment builder needed to replace an aging AC fan inside a control cabinet that could not be taken offline for more than an hour. By cross-referencing the frame dimensions, voltage and airflow curve, we supplied a current-series drop-in replacement with a matching tachometer signal, and the swap was completed during a scheduled maintenance window.
Refrigeration and cold chain customers bring us another pattern: the failed condenser fan is unavailable for weeks. Comparing diameter, speed, bearings and IP rating, we supply a functionally equivalent unit from stock so the system returns to duty the same week — the reason many service companies keep our contact number on file.
From one-piece emergency replacements to volume supply for equipment manufacturers, every SUNON enquiry is handled by the same rule: verify the parameters first, then quote — so what arrives on site is the fan the project actually needs.
Single-piece orders and samples are welcome — many customers validate one unit in their system before committing to volume. There is no minimum order quantity for standard stock models, and the sample price is deducted from the bulk order in most repeat purchases. Tell us the quantity you plan to use and we will quote both scenarios.
Yes. Beyond catalogue models we can discuss modified lead wires, connectors, speed curves, IP upgrades or private-label packaging for OEM projects. Customization usually starts from a defined annual quantity; our engineers will review your requirement and confirm feasibility, tooling cost and lead time before any commitment.
Every unit is covered by the manufacturer's warranty against defects in materials and workmanship, and we support you through the whole claim process so you deal with one supplier instead of chasing a factory overseas. If a failure appears in service, send us the serial number, operating conditions and photos, and we will arrange the replacement or credit path agreed in the quotation.
Bag
Bag packaging indicates that a specified quantity of product is packaged by the manufacturer in a bag, sealed pouch, or similar container and sold as a unit without repackaging. It is also used to describe kits/assortments where components are packaged in separate bags according to part number or parametric value, rather than in a compartmentalized box or similar rigid container.