PF92252B1-1000U-A99 is a 24 VDC centrifugal fan for servers, medical equipment, laboratory equipment. Its main supplied feature is 127.5 m³/h maximum airflow stated for this model. It also lists a 92*92*25 mm size specified in the upload data. Review acoustic limit for technical approval.
| Rated Voltage(V) | 24 |
|---|---|
| Size(mm) | 92*92*25 |
| Max.Air Flow(m³/h) | 127.5 |
| Input Power(W) | 4.92 |
| Speed(rpm) | 4500 |
| Noise(db) | 46.1 |
SUNON PF92252B1-1000U-A99 is a DC blower fan selected for data centers and communication hardware, where controlled moving air protects operating margin in constrained-space or continuously loaded hardware.
The 4500 rpm speed and 46.1 dB sound entry aid hardware-level thermal and acoustic review.
Its directed outlet enables forced-air cooling air to reach a specific heat source when a straight-through axial path is impractical.
OEM qualification should connect the fan choice to enclosure resistance, acoustic limits and the expected operating environment. Confirm the exact operating point before production release. Preserve the specified moving air direction during assembly. Review the approved electrical interface for the complete suffix.
The application of PF92252B1-1000U-A99 covers servers and data-communication hardware; here, the DC blower fan cools computing and network assemblies. Sustained operation requires an airflow component that integrates cleanly with the machinery architecture.
Within power supplies, inverters and control cabinets, PF92252B1-1000U-A99 cools power modules and controls as a SUNON DC blower fan. Engineering teams should verify mounting, air delivery direction and installation resistance to preserve the intended application value.
Model PF92252B1-1000U-A99 contributes to office, imaging and household appliances by providing ventilation flow that removes appliance heat. Controlled circulation helps reduce temperature gradients across boards, power sections and mechanical assemblies.
As part of medical and laboratory instruments, SUNON PF92252B1-1000U-A99 performs a defined temperature management task and cools enclosed instrument electronics. Engineers should verify mounting, temperature management flow direction and unit resistance to preserve the intended application value.
The upload sheet marks the item as In Stock, but available quantity should be confirmed when the order is placed.
The upload row lists 24 VDC. Confirm phase, frequency, terminals, and local supply conditions before wiring.
The upload row lists 46.1 dB. Confirm the measurement condition and compare noise at the intended operating point.
The matched source highlights 127.5 m³/h maximum airflow stated for this model. Compare that point together with the listed electrical and dimensional data.
The supplied sources do not confirm an integrated controller. Verify the exact electrical variant and control requirement before ordering.
The supplied files do not establish a universal 24/7 duty rating. Validate ambient conditions, duty cycle, protection, and maintenance requirements for continuous use.

For servers and data-center electronics, PF60252B2-10000-A99 combines 24 VDC operation with a 60 × 60 × 25 mm DC axial fan design. 124.5 Pa maximum pressure is the standout documented duty-point value. Use the documented speed benchmark when planning installation review. Obtain the applicable curve before final duty-point approval.
Read More
The PF60252B1-10000-A99 is SUNON's 24 VDC, 60 × 60 × 25 mm DC axial fan option for servers and data-center electronics. 139.5 Pa maximum pressure is the standout documented duty-point value. Review its airflow profile during installation review. Obtain the applicable curve before final duty-point approval.
Read More
The PF60251B3-10000-A99 is SUNON's 12 VDC, 60 × 60 × 25 mm DC axial fan option for servers and data-center electronics. 102.1 Pa maximum pressure is the standout documented duty-point value. Use the documented cooling specification when planning design qualification. Match the exact part number before approving a substitute.
Read More
For compact cooling within servers and data-center electronics, the PF60251B2-10000-A99 provides a 12 VDC DC axial fan configuration measuring 60 × 60 × 25 mm. 124.5 Pa maximum pressure is the standout documented duty-point value. Review its duty-point values during design qualification. Match the exact part number before approving a substitute.
Read More
SUNON PF60251B1-10000-A99 combines a 60 × 60 × 25 mm DC axial fan platform with a 12 VDC rating for servers and data-center electronics. 139.5 Pa maximum pressure is the standout documented duty-point value. Treat the installation footprint as a primary input to design qualification. Match the exact part number before approving a substitute.
Read More
Within servers and data-center electronics, SUNON PF40561B1-10000-A9H serves as a 40 × 40 × 56 mm DC axial fan operating at 12 VDC. 657.6 Pa maximum pressure is the standout documented duty-point value. During design qualification, compare the model's rated dataset. Match the exact part number before approving a substitute.
Read More