Home > Products > By type > Blower Fans > PF97331B1-B00U-S99 | SUNON 12VDC 19.2W 97x97x33mm DC Centrifugal Blower for data center cooling

PF97331B1-B00U-S99 SUNON Blower Fan

Brand :
SUNON
Model:
PF97331B1-B00U-S99 | SUNON 12VDC 19.2W 97x97x33mm DC Centrifugal Blower for data center cooling
Type:
Blower Fans
Industry:
Data Center Cooling
Description:

PF97331B1-B00U-S99 is a 12 VDC centrifugal fan for servers, medical equipment, laboratory equipment. Its main supplied feature is 5400 rpm rated speed in the supplied parameter row. It also lists a 97x97x33mm mm size specified in the upload data. Review power budget for replacement review.

Product Features

Rated Voltage(V)12
Size(mm)97x97x33mm
Max.Air Flow(m³/h)75.14
Max.Pressure(Pa)844.4
Input Power(W)19.2
Speed(rpm)5400
Noise(db)58

Product Features

Directed Cooling

PF97331B1-B00U-S99 gives designers of data centers and communication assembly a SUNON DC blower fan option for routing air through limited spaces and thermally active sections.

Directional discharge gives assembly designers a controlled method for moving air through narrow or high-impedance sections.

The 5400 rpm speed and 58 dB sound entry aid assembly-level thermal and acoustic review.

Prototype testing can verify the in-system moving air path and prevent free-air data from being mistaken for in-assembly performance. Check environmental limits in the original product data. Confirm the exact operating point before production release. Preserve the specified moving air direction during assembly.

Application Industry

Frequently Asked Questions

What noise data is available for PF97331B1-B00U-S99?

The upload row lists 58 dB. Confirm the measurement condition and compare noise at the intended operating point.

How should PF97331B1-B00U-S99 be maintained?

No model-specific maintenance interval is supplied. Keep the airflow path clean, inspect mounting and electrical connections, and follow the exact product instructions.

Does PF97331B1-B00U-S99 require a separate controller?

The supplied sources do not confirm an integrated controller. Verify the exact electrical variant and control requirement before ordering.

Is PF97331B1-B00U-S99 suitable for a high-reliability cooling system?

It may be evaluated for high-reliability cooling using the supplied parameters, but duty cycle, redundancy, ambient limits, and protection must be confirmed at system level.

What should be checked before installing PF97331B1-B00U-S99?

Check electrical supply, mounting clearance, fasteners, airflow direction, guards, wiring, and access for service before installation.

Which application details should be confirmed before ordering PF97331B1-B00U-S99?

Confirm the target equipment, operating point, ambient conditions, installation space, electrical supply, controls, protection, quantity, and required delivery date.