MF40101VX-1000U-A99 is a 12 VDC axial fan for servers, data-communications equipment, control cabinets. Its main supplied feature is 1.05 W input power for the listed electrical version. It also lists a 40*40*10 mm size specified in the upload data. Review system resistance for replacement review.
| Rated Voltage(V) | 12 |
|---|---|
| Size(mm) | 40*40*10 |
| Max.Air Flow(m³/h) | 16.83 |
| Max.Pressure(Pa) | 62.3 |
| Input Power(W) | 1.05 |
| Speed(rpm) | 8500 |
| Noise(db) | 31.4 |
The SUNON MF40101VX-1000U-A99 contributes to data centers and communication assembly as a DC axial fan, combining a small-footprint cooling role with a clear mechanical and electrical integration path.
Air enters and leaves in the axial direction, supporting efficient exchange across open enclosures, electronics and ventilation paths.
The 8500 rpm speed and 31.4 dB sound entry aid assembly-level thermal and acoustic review.
System validation should include realistic filters, grilles and neighboring components because these elements influence delivered ventilation flow. Preserve the specified ventilation flow direction during assembly. Review the approved electrical interface for the complete suffix. Validate sound and temperature in the finished enclosure.
Model MF40101VX-1000U-A99 contributes to servers and data-communication hardware by providing air delivery that cools computing and network assemblies. Service teams benefit when the full suffix and installation position remain recorded in equipment documentation.
Installation serving power supplies, inverters and control cabinets can integrate SUNON MF40101VX-1000U-A99; the unit cools power modules and controls. This provides B2B buyers with a model-specific basis for engineering approval, purchasing and maintenance.
SUNON supplies model MF40101VX-1000U-A99 for industrial automation assembly, where directed moving air ventilates drives and production electronics. This approach helps manufacturers balance forced-air cooling effectiveness, enclosure space and lifecycle maintenance.
MF40101VX-1000U-A99 reinforces medical and laboratory instruments by using its DC axial fan format to cools enclosed instrument electronics. This gives assembly makers a practical forced-air cooling element that reinforces application reliability without changing the stated industry direction.
No guaranteed lead time is provided in the supplied sources. Confirm current stock, required quantity, production schedule, and shipping date with the supplier.
The supplied row lists 16.83 m³/h airflow, 62.3 Pa pressure, 1.05 W input, 8500 rpm, 31.4 dB. Compare these values with the real system operating point, not only the free-air rating.
It may be evaluated for high-reliability cooling using the supplied parameters, but duty cycle, redundancy, ambient limits, and protection must be confirmed at system level.
The supplied application data covers servers, data-communications equipment, control cabinets. Confirm the installation's airflow, pressure, space, and electrical requirements.
No quantified cost-saving claim is supplied for this exact item. Compare energy use, controls, service needs, and purchase cost using the required duty point.
The upload sheet marks the item as In Stock, but available quantity should be confirmed when the order is placed.