MF50152VX-1000U-A99 is a 24 VDC axial fan for servers, data-communications equipment, control cabinets. Its main supplied feature is 77.2 Pa maximum pressure stated for this model. It also lists a 50*50*15 mm size specified in the upload data. Review electrical supply for compatibility checking.
| Rated Voltage(V) | 24 |
|---|---|
| Size(mm) | 50*50*15 |
| Max.Air Flow(m³/h) | 31.62 |
| Max.Pressure(Pa) | 77.2 |
| Input Power(W) | 1.32 |
| Speed(rpm) | 7200 |
| Noise(db) | 38.1 |
SUNON MF50152VX-1000U-A99 addresses assembly heat removal in data centers and communication assembly with a DC axial fan architecture suited to repeatable installation and service identification.
Air enters and leaves in the axial direction, supporting efficient exchange across open enclosures, electronics and ventilation paths.
Listed air movement of 31.62 m3/h and pressure of 77.2 Pa provide starting points for duty-point evaluation in the completed assembly.
The result is a practical heat removal component for manufacturers balancing thermal performance, installation space and lifecycle service. Keep the model reference unchanged in replacement documentation. Check environmental limits in the original product data.
SUNON supplies model MF50152VX-1000U-A99 for servers and data-communication hardware, where directed air movement cools computing and network assemblies. The result contributes to stable duty while keeping the cooling function understandable for future service work.
When production in power supplies, inverters and control cabinets, MF50152VX-1000U-A99 cools power modules and controls within the available assembly space. The application values controlled ventilation because internal space and acoustic limits constrain heat removal choices.
SUNON MF50152VX-1000U-A99 is used in industrial automation installation, where the DC axial fan ventilates drives and production electronics. Engineering teams should verify mounting, air delivery direction and installation resistance to preserve the intended application value.
When installed in medical and laboratory instruments, MF50152VX-1000U-A99 cools enclosed instrument electronics within the available installation space. A confirmed operating point provides a stronger purchasing basis than selecting from maximum temperature management flow alone.
The upload row lists 38.1 dB. Confirm the measurement condition and compare noise at the intended operating point.
No model-specific maintenance interval is supplied. Keep the airflow path clean, inspect mounting and electrical connections, and follow the exact product instructions.
The supplied row lists 31.62 m³/h airflow, 77.2 Pa pressure, 1.32 W input, 7200 rpm, 38.1 dB. Compare these values with the real system operating point, not only the free-air rating.
The supplied files do not establish a universal 24/7 duty rating. Validate ambient conditions, duty cycle, protection, and maintenance requirements for continuous use.
Available performance data includes 31.62 m³/h airflow, 77.2 Pa pressure, 1.32 W input, 7200 rpm, 38.1 dB. Obtain the full curve when system resistance or part-load behavior matters.
Match the complete model code, voltage, dimensions, mounting arrangement, airflow direction, performance point, and control interface to the equipment.