109-602 is a 200 VAC axial fan for servers, data-communications equipment, control cabinets. Its main supplied feature is a 160*160*51 mm size specified in the upload data. It also lists 432 m³/h maximum airflow stated for this model. Review control method for energy review. Check the exact variant before ordering.
| Rated Voltage(V) | 200 |
|---|---|
| Size(mm) | 160*160*51 |
| Max.Air Flow(m³/h) | 432 |
| Max.Pressure(Pa) | 156.8 |
| Input Power(W) | 37.5 |
| Speed(rpm) | 2850 |
| Noise(db) | 56 |
The 109-602 brings SANYO DENKI AC axial fan performance to data centers and communication machinery. It gives OEM specialists a defined component for forced-air thermal management.
The straight-through temperature management flow geometry simplifies integration into panels, cabinets and machinery zones that need broad air exchange.
Machinery designers gain a traceable temperature management specification that can be reviewed by engineering, purchasing and maintenance teams.
The stated 160*160*51 mm size supports early mechanical-envelope and mounting checks. Review the approved electrical interface for the complete suffix. Validate sound and temperature in the finished enclosure. Keep the model reference unchanged in replacement documentation.
The application of 109-602 covers servers and data-communication hardware; here, the AC axial fan cools computing and network assemblies. The result reinforces controlled running while keeping the heat removal function understandable for future service work.
As part of power supplies, inverters and control cabinets, SANYO DENKI 109-602 performs a defined heat removal task and cools power modules and controls. The result reinforces stable function while keeping the heat removal function understandable for future service work.
The thermal control role of SANYO DENKI 109-602 in industrial automation installation is to ventilates drives and production electronics. Forced-air thermal control supports installation availability during long duty cycles and repeated load changes.
For hardware in medical and laboratory instruments, SANYO DENKI 109-602 acts as a forced-air cooling component that cools enclosed instrument electronics. A defined air route reinforces repeatable thermal behavior across production units and service replacements.
Its advantage should be judged from the matched series feature, exact size, electrical rating, and available performance data rather than from a generic fan comparison.
The supplied files do not establish a universal 24/7 duty rating. Validate ambient conditions, duty cycle, protection, and maintenance requirements for continuous use.
The supplied application data covers servers, data-communications equipment, control cabinets. Confirm the installation's airflow, pressure, space, and electrical requirements.
No quantified cost-saving claim is supplied for this exact item. Compare energy use, controls, service needs, and purchase cost using the required duty point.
The upload row lists RoHS compliance, but no additional exact-model certification is confirmed in the supplied feature record.
The upload row lists 200 VAC. Confirm phase, frequency, terminals, and local supply conditions before wiring.

The 109-043UL is a Sanyo Denki 115 VAC, 80 × 80 × 42 mm AC axial fan for servers, UPS systems, and telecom equipment. Series options require suffix verification. Review its mounting size during power-budget planning. Confirm control inputs against the complete ordering code. Focus: service access planning ventilation capacity.
Read More
The 109S051 is a Sanyo Denki 200 VAC, 80 × 80 × 25 mm AC axial fan for servers, UPS systems, and telecom equipment. Series options require suffix verification. For compatibility checking, start with the supplied pressure capability. Review connector, alarm, and sensor options separately. Focus: service access planning installation footprint.
Read More
109P0412M901 is a 12 VDC axial fan for servers, data-communications equipment, control cabinets. Its main supplied feature is 0.72 W input power for the listed electrical version. It also lists a 40*40*10 mm size specified in the upload data. Review equipment interface for retrofit assessment.
Read More
109P0412H701 addresses servers, UPS systems, and telecom equipment through a 12 VDC DC axial fan platform measuring 40 × 40 × 15 mm. Series focus: high airflow and pressure. The 11 m³/h airflow figure supports its stated equipment-cooling role. Check compatibility risk checking acoustic value. Focus: compatibility risk checking acoustic value.
Read More
For servers, UPS systems, and telecom equipment, 109P0612K701 combines 12 VDC operation with a 60 × 60 × 15 mm DC axial fan design. High airflow is highlighted together with a high-static-pressure design. The 36.8 m³/h airflow figure supports its stated equipment-cooling role. Check compatibility risk checking airflow profile.
Read More
A 60 × 60 × 25 mm frame and 5 VDC rating define 109R0605M401, a DC axial fan for servers, UPS systems, and telecom equipment. Series focus: high airflow and pressure. A listed noise figure of 20 dB is the key differentiating parameter. Check service access planning selection parameters. Focus: service access planning selection parameters.
Read More