A 60 × 60 × 25 mm frame and 5 VDC rating define 109R0605M401, a DC axial fan for servers, UPS systems, and telecom equipment. Series focus: high airflow and pressure. A listed noise figure of 20 dB is the key differentiating parameter. Check service access planning selection parameters. Focus: service access planning selection parameters.
| Rated Voltage(V) | 5 |
|---|---|
| Size(mm) | 60*60*25 |
| Max.Air Flow(m³/h) | 21.4 |
| Max.Pressure(Pa) | 19.6 |
| Speed(rpm) | 2600 |
| Noise(db) | 20 |
For servers, storage systems and ICT equipment, the SANYO DENKI 109R0605M401 provides DC axial fan cooling in an integration-ready format. It establishes an active air path through restricted equipment spaces.
A listed maximum airflow of 21.4 m3/h and maximum pressure of 19.6 Pa give engineers a clear basis for matching the fan to enclosure resistance. Buyers should confirm the complete suffix, connector, sensor output and control option before ordering. Engineers should validate the operating point with the actual grille and filter.
Confirm the operating environment for the suffix. It supports a clear fan specification for future servicing. Confirm the final fan curve in the assembled equipment.
109R0605M401 is suitable for server chassis and computing nodes. These systems need continuous heat removal because compact layouts and rising power density restrict natural convection. The application supports stable equipment service. Selection should follow the approved full model code.
The San Ace 109R0605M401 supports thermal management in storage arrays and data appliances. These systems need continuous heat removal because compact layouts and rising power density restrict natural convection. The application supports stable equipment service.
For network and other ICT hardware, 109R0605M401 provides a dedicated forced-air cooling path. These systems need continuous heat removal because compact layouts and rising power density restrict natural convection. The application supports stable equipment service.
No exact IP rating is supplied for this model row. Check the current model datasheet before use in water, dust, or oil exposure.
PWM or sensor functions depend on the exact suffix. Confirm the control lead and interface in the applicable Sanyo Denki datasheet.
Its 5 VDC rating and documented a listed noise figure of 20 db is the key differentiating parameter. provide model-specific selection data without relying on unlisted claims.
The worksheet lists 5 VDC. Check polarity or AC frequency and the wiring diagram before commissioning.
Verify supply, connector, obstructions, impeller movement, and alarm or protection status using the model-specific troubleshooting data.

The R3G310-8317083844 serves Cleanroom as an EC backward-curved centrifugal fan, with 310 mm dimensions for installation planning as its clearest supplied attribute. No rated voltage is listed in the provided table.
Read More
For Cleanroom, R3G400-8317084403 provides an EC backward-curved centrifugal fan format with 400 mm dimensions for installation planning. Rated voltage is not shown in the supplied table and must be checked before selection.
Read More
Intended for Cleanroom, the R3G400-8317080005 is an EC backward-curved centrifugal fan characterized by 400 mm dimensions for installation planning. Its rated voltage is absent from the supplied data and requires confirmation.
Read More
Specified as an EC backward-curved centrifugal fan for Cleanroom, R3G355-8317084543 is distinguished by 355 mm dimensions for installation planning. Confirm rated voltage separately because it is not present in the supplied table.
Read More
R3G355-8317081321 is an EC backward-curved centrifugal fan for Cleanroom; the supplied table does not state its rated voltage. Its representative listed feature is 355 mm dimensions for installation planning.
Read More
R3G400-8317080492 targets Cleanroom in an EC backward-curved centrifugal fan configuration. The available data highlights 400 mm dimensions for installation planning, but does not provide a rated-voltage value.
Read More