Home > Products > By type > Axial Fans > 109P0612K701 | Sanyo Denki 12VDC 3.12W DC Axial Fan for UPS, server and telecom equipment cooling

109P0612K701 Sanyo Axial Fan

Brand :
Sanyo
Model:
109P0612K701 | Sanyo Denki 12VDC 3.12W DC Axial Fan for UPS, server and telecom equipment cooling
Type:
Axial Fans
Industry:
Data Center Cooling
Description:

For servers, UPS systems, and telecom equipment, 109P0612K701 combines 12 VDC operation with a 60 × 60 × 15 mm DC axial fan design. High airflow is highlighted together with a high-static-pressure design. The 36.8 m³/h airflow figure supports its stated equipment-cooling role. Check compatibility risk checking airflow profile.

Product Features

Rated Voltage(V)12
Size(mm)60*60*15
Max.Air Flow(m³/h)36.8
Max.Pressure(Pa)99.3
Input Power(W)3.12
Speed(rpm)6500
Noise(db)45

Product Features

High Airflow Design

SANYO DENKI positions 109P0612K701 as a DC axial fan for servers, storage systems and ICT equipment. It helps equipment designers manage local hot spots where natural convection is insufficient.

With up to 36.8 m3/h airflow and 99.3 Pa static pressure, the model can move cooling air through vents, filters and compact internal passages. Buyers should confirm the complete suffix, connector, sensor output and control option before ordering. Engineers should validate the operating point with the actual grille and filter.

Test component temperatures at peak load. It helps maintenance teams plan compatible replacements. Confirm the final fan curve in the assembled equipment. Preserve clear inlet and outlet space during installation.

Application Industry

Frequently Asked Questions

What input power is listed for 109P0612K701?

The worksheet lists 3.12 W. Check supply capacity and operating conditions before commissioning.

Can 109P0612K701 run continuously in a 24/7 system?

Verify the exact bearing, rated life, temperature range, and duty limits. The supplied family description alone does not confirm continuous operation for every suffix.

What bearing type does 109P0612K701 use?

The exact bearing is not stated in the supplied row. Confirm it from the complete model suffix and current Sanyo Denki datasheet.

How should 109P0612K701 be matched to an enclosure?

Check its 60 × 60 × 15 mm size, 36.8 m³/h airflow, 99.3 Pa pressure, mounting points, airflow direction, and system resistance.

What certifications apply to 109P0612K701?

The workbook marks it RoHS compliant. Confirm model-specific UL, CSA, TÜV, or other required approvals from official documentation.

Can 109P0612K701 replace another fan directly?

Match voltage, size, mounting, airflow direction, airflow, pressure, connector, control signal, and protection before substitution.