Get Quote
Home > Products > By type > Axial Fans > 109P0412M901 | SANYO DENKI 12VDC 0.72W 40x40x10mm DC Axial Fan for data center cooling

109P0412M901 Sanyo Axial Fan

Brand :
Sanyo
Model:
109P0412M901 | SANYO DENKI 12VDC 0.72W 40x40x10mm DC Axial Fan for data center cooling
Type:
Axial Fans
Industry:
Data Center Cooling
Description:

109P0412M901 is a 12 VDC axial fan for servers, data-communications equipment, control cabinets. Its main supplied feature is 0.72 W input power for the listed electrical version. It also lists a 40*40*10 mm size specified in the upload data. Review equipment interface for retrofit assessment.

Product Features

Rated Voltage(V)12
Size(mm)40*40*10
Max.Air Flow(m³/h)7.2
Max.Pressure(Pa)27
Input Power(W)0.72
Speed(rpm)5000
Noise(db)21

Product Features

Efficient DC Fan

SANYO DENKI 109P0412M901 is a DC axial fan selected for data centers and communication assembly, where controlled moving air protects operating margin in constrained-space or continuously loaded assembly.

This helps designers translate moving air into lower component temperature, steadier duty and a more repeatable assembly design.

Air enters and leaves in the axial direction, supporting efficient exchange across open enclosures, electronics and ventilation paths.

Listed moving air of 7.2 m3/h and pressure of 27 Pa provide starting points for duty-point evaluation in the completed system. Confirm the exact operating point before production release. Preserve the specified moving air direction during assembly.

Application Industry

Frequently Asked Questions

What rated voltage is listed for 109P0412M901?

The upload row lists 12 VDC. Confirm phase, frequency, terminals, and local supply conditions before wiring.

What should I check if 109P0412M901 develops a cooling fault?

Check supply voltage, controller signals, blocked airflow, contamination, abnormal noise, rotation, and the equipment operating point before replacing the unit.

Which supplied feature distinguishes 109P0412M901?

The matched source highlights 0.72 W input power for the listed electrical version. Compare that point together with the listed electrical and dimensional data.

Which performance values should I compare for 109P0412M901?

The supplied row lists 7.2 m³/h airflow, 27 Pa pressure, 0.72 W input, 5000 rpm, 21 dB. Compare these values with the real system operating point, not only the free-air rating.

Can 109P0412M901 be considered for continuous operation?

The supplied files do not establish a universal 24/7 duty rating. Validate ambient conditions, duty cycle, protection, and maintenance requirements for continuous use.

What equipment is 109P0412M901 suited to?

The supplied application data covers servers, data-communications equipment, control cabinets. Confirm the installation's airflow, pressure, space, and electrical requirements.