Get Quote
Home > Products > By type > Axial Fans > 9G0924G102 | Sanyo Denki 24VDC 13.2W DC Axial Fan for UPS, server and telecom equipment cooling

9G0924G102 Sanyo Axial Fan

Brand :
Sanyo
Model:
9G0924G102 | Sanyo Denki 24VDC 13.2W DC Axial Fan for UPS, server and telecom equipment cooling
Type:
Axial Fans
Industry:
Data Center Cooling
Description:

The 9G0924G102 is a Sanyo Denki 24 VDC, 92 × 92 × 38 mm DC axial fan for servers, UPS systems, and telecom equipment. Series focus: high airflow and pressure. For fan selection, start with the supplied equipment fit. Confirm control inputs against the complete ordering code. Focus: lifecycle requirement review catalog specification.

Product Features

Rated Voltage(V)24
Size(mm)92*92*38
Max.Air Flow(m³/h)184.8
Max.Pressure(Pa)149.9
Input Power(W)13.2
Speed(rpm)5000
Noise(db)50

Product Features

Stable San Ace Fan

The SANYO DENKI 9G0924G102 is a DC axial fan developed for servers, storage systems and ICT equipment. Its directed airflow helps remove heat from densely arranged components and supports predictable equipment temperatures.

With up to 184.8 m3/h airflow and 149.9 Pa static pressure, the model can move cooling air through vents, filters and compact internal passages. For design approval, verify airflow direction, connector details and available control signals. Prototype testing should include the final vents, guards and component loading.

Check exhaust separation from the intake zone. It also creates a clearer thermal approval record. Confirm the final fan curve in the assembled equipment.

Application Industry

Frequently Asked Questions

What should procurement confirm for 9G0924G102?

Confirm full suffix, voltage, connector, control signal, bearing, IP rating, certifications, stock, and required delivery date.

Does 9G0924G102 have a pressure rating?

The worksheet lists 149.9 Pa. Use the official curve to match it to system resistance.

Is 9G0924G102 suitable for high-reliability cooling?

Evaluate the exact bearing, life, temperature, alarm, and protection data. Correct sizing and clean airflow are also required for reliable operation.

Can 9G0924G102 replace another fan directly?

Match voltage, size, mounting, airflow direction, airflow, pressure, connector, control signal, and protection before substitution.

What maintenance does 9G0924G102 require?

Inspect dust buildup, airflow blockage, abnormal noise, mounting security, and wiring condition; disconnect power before service.

Can 9G0924G102 reduce total operating cost?

Compare its listed power with the required airflow, pressure, and operating hours. System-level savings depend on correct duty-point selection.

Message Form