For thermal management in servers, UPS systems, and telecom equipment, the 9GA0824P1S61 provides a 24 VDC DC axial fan configuration measuring 80 × 80 × 38 mm. 480 Pa maximum pressure is the most distinctive duty-point parameter. Base cooling-margin review on the stated electrical load. Confirm environmental protection for the ordered version.
| Rated Voltage(V) | 24 |
|---|---|
| Size(mm) | 80*80*38 |
| Max.Air Flow(m³/h) | 156 |
| Max.Pressure(Pa) | 480 |
| Input Power(W) | 11.28 |
| Speed(rpm) | 9550 |
| Noise(db) | 59 |
9GA0824P1S61 brings San Ace DC axial fan cooling to servers, storage systems and ICT equipment. The compact air-moving design suits OEM assemblies that require continuous ventilation around electronic and power components.
Its 156 m3/h maximum airflow supports rapid air exchange, while 480 Pa pressure capability helps overcome resistance within the finished equipment. Selection should include a system-resistance review, mounting check and harness confirmation. The full model code matters because signal and lead options can differ within a series.
Qualify performance with the production guard. This confirms cooling margin before volume production. Confirm the final fan curve in the assembled equipment.
SANYO DENKI 9GA0824P1S61 serves server chassis and computing nodes that operate with sustained internal heat. Reliable ventilation reduces hot spots around sensitive electronics and supports consistent equipment availability. It supports reliable OEM equipment cooling.
9GA0824P1S61 is suitable for storage arrays and data appliances. Air circulation around processors, power devices and control electronics limits heat concentration and supports stable operation. This helps maintain dependable equipment operation. Selection should follow the approved full model code.
The San Ace 9GA0824P1S61 supports thermal management in network and other ICT hardware. Air circulation around processors, power devices and control electronics limits heat concentration and supports stable operation. This helps maintain dependable equipment operation.
Confirm full suffix, voltage, connector, control signal, bearing, IP rating, certifications, stock, and required delivery date.
The worksheet lists 480 Pa. Use the official curve to match it to system resistance.
It is listed for servers, UPS systems, and telecom equipment. Confirm airflow, pressure, dimensions, and environmental conditions against the actual equipment.
Match voltage, size, mounting, airflow direction, airflow, pressure, connector, control signal, and protection before substitution.
The worksheet lists 156 m³/h. Compare the operating point with system resistance and the official performance curve.
Its 24 VDC rating and documented 480 pa maximum pressure is the most distinctive duty-point parameter. provide model-specific selection data without relying on unlisted claims.