A 80 × 80 × 38 mm frame and 12 VDC rating define 9GA0812P1G61, a DC axial fan for servers, UPS systems, and telecom equipment. Long-life series construction is the main characteristic stated in the supplied reference. 480 Pa maximum pressure is the most distinctive duty-point parameter. Selection focus: spares strategy planning sound level.
| Rated Voltage(V) | 12 |
|---|---|
| Size(mm) | 80*80*38 mm |
| Max.Air Flow(m³/h) | 171 |
| Max.Pressure(Pa) | 480 |
| Input Power(W) | 14.4 |
| Speed(rpm) | 10500 |
| Noise(db) | 60 |
The SANYO DENKI 9GA0812P1G61 is a DC axial fan developed for servers, storage systems and ICT equipment. Its directed airflow helps remove heat from densely arranged components and supports predictable equipment temperatures.
The rated peak airflow of 171 m3/h combines with 480 Pa pressure capability to support useful flow after installation losses are considered. Selection should include a system-resistance review, mounting check and harness confirmation. The full model code matters because signal and lead options can differ within a series.
Check exhaust separation from the intake zone. This improves consistency between prototype and production. Confirm the final fan curve in the assembled equipment.
For server chassis and computing nodes, 9GA0812P1G61 provides a dedicated forced-air cooling path. Air circulation around processors, power devices and control electronics limits heat concentration and supports stable operation. The application supports stable equipment service.
SANYO DENKI 9GA0812P1G61 serves storage arrays and data appliances that operate with sustained internal heat. Air circulation around processors, power devices and control electronics limits heat concentration and supports stable operation. The application supports stable equipment service.
9GA0812P1G61 is suitable for network and other ICT hardware. These systems need continuous heat removal because compact layouts and rising power density restrict natural convection. The application supports stable equipment service. Selection should follow the approved full model code.
The reference lists IP20. Confirm that the exact ordered suffix carries the required environmental rating.
Inspect dust buildup, airflow blockage, abnormal noise, mounting security, and wiring condition; disconnect power before service.
Compare its listed power with the required airflow, pressure, and operating hours. System-level savings depend on correct duty-point selection.
The worksheet lists 14.4 W. Check supply capacity and operating conditions before commissioning.
Verify supply, connector, obstructions, impeller movement, and alarm or protection status using the model-specific troubleshooting data.