| Mfr Part # | Rated Voltage(V) | Size(mm) | Max.Air Flow(m³/h) | Max.Pressure(Pa) | Input Power(W) | Speed(rpm) | Noise(db) | |
|---|---|---|---|---|---|---|---|---|
![]() 9GL1224G102 | Sanyo Denki 24VDC 12W DC Axial Fan for UPS, server and telecom equipment cooling A 119 × 119 × 38 mm frame and 24 VDC rating define 9GL1224G102, a DC axial fan for servers, UPS systems, and telecom equipment. Series focus: high airflow and pressure. Its listed airflow of 230.4 m³/h is the standout performance value. Check cabinet ventilation planning selection parameters. Focus: cabinet ventilation planning. |
24 | 119*119*38 | 230.4 | 135 | 12 | 3600 | 49 | |
![]() 109P0512H720 | Sanyo Denki 12VDC DC Axial Fan for UPS, server and telecom equipment cooling 109P0512H720 addresses servers, UPS systems, and telecom equipment through a 12 VDC DC axial fan platform measuring 52 × 52 × 15 mm. Series focus: high airflow and pressure. The 52 × 52 × 15 mm format is the primary stated selection detail. Check cabinet ventilation planning rated dataset. Focus: cabinet ventilation planning rated dataset. |
12 | 52*52*15 | - | - | - | - | - | |
![]() 9A0912S401 | Sanyo Denki 12VDC 3.24W DC Axial Fan for UPS, server and telecom equipment cooling Sanyo Denki 9A0912S401 combines a 92 × 92 × 25 mm DC axial fan platform with a 12 VDC rating for servers, UPS systems, and telecom equipment. High airflow is highlighted together with a high-static-pressure design. 56.1 Pa maximum pressure is the most distinctive duty-point parameter. Selection focus: cabinet ventilation planning motor input. |
12 | 92*92*25 | 100 | 56.1 | 3.24 | 3550 | 39 | |
![]() 109E1348G101 | Sanyo Denki 48VDC 25.9W DC Axial Fan for UPS, server and telecom equipment cooling Sanyo Denki configures 109E1348G101 for servers, UPS systems, and telecom equipment as a 48 VDC DC axial fan with 127 × 127 × 38 mm dimensions. Its listed airflow of 340 m³/h is the standout performance value. During cooling-margin review, compare the model's equipment fit. Use the latest specification for frequency and tolerance limits. |
48 | 127*127*38 | 340 | 216 | 25.9 | 4550 | 57 | |
![]() 109R0612G429 | Sanyo Denki 12VDC DC Axial Fan for UPS, server and telecom equipment cooling 109R0612G429 serves servers, UPS systems, and telecom equipment as a 60 × 60 × 25 mm DC axial fan rated at 12 VDC. Series focus: high airflow and pressure. The 60 × 60 × 25 mm format is the primary stated selection detail. Check cabinet ventilation planning equipment fit. Focus: cabinet ventilation planning equipment fit. |
12 | 60*60*25 | - | - | - | - | - | |
![]() 109P0912H402 | Sanyo Denki 12VDC 2.52W DC Axial Fan for UPS, server and telecom equipment cooling For thermal management in servers, UPS systems, and telecom equipment, the 109P0912H402 provides a 12 VDC DC axial fan configuration measuring 92 × 92 × 25 mm. Its 2850 rpm rating defines a lower-speed operating point. During enclosure sizing, compare the model's acoustic value. Confirm environmental protection for the ordered version. |
12 | 92*92*25 | 87.04 | 45.1 | 2.52 | 2850 | 33 | |
![]() 109P0405M902 | Sanyo Denki 5VDC 0.55W DC Axial Fan for UPS, server and telecom equipment cooling Sanyo Denki 109P0405M902 is a 5 VDC DC axial fan in a 40 × 40 × 10 mm format for servers, UPS systems, and telecom equipment. Series focus: high airflow and pressure. A listed input of 0.55 W is the notable efficiency-related parameter. Check cabinet ventilation planning catalog specification. Focus: cabinet ventilation planning. |
5 | 40*40*10 | 7.14 | 27 | 0.55 | 5000 | 21 | |
![]() 9G0812G1D01 | Sanyo Denki 12VDC 13.2W DC Axial Fan for UPS, server and telecom equipment cooling For thermal management in servers, UPS systems, and telecom equipment, the 9G0812G1D01 provides a 12 VDC DC axial fan configuration measuring 80 × 80 × 38 mm. 13.2 W input is the defining electrical-load figure. The recorded acoustic value should guide duty-point matching. Obtain the applicable curve before final duty-point approval. |
12 | 80*80*38 | 151.2 | 211 | 13.2 | 6300 | 51 | |
![]() 9A0612G4011 | Sanyo Denki 12VDC 2.88W DC Axial Fan for UPS, server and telecom equipment cooling Sanyo Denki 9A0612G4011 combines a 60 × 60 × 25 mm DC axial fan platform with a 12 VDC rating for servers, UPS systems, and telecom equipment. High airflow is highlighted together with a high-static-pressure design. A listed input of 2.88 W is the notable efficiency-related parameter. Selection focus: cabinet ventilation planning performance curve. |
12 | 60*60*25 | 47 | 87.3 | 2.88 | 5600 | 39 | |
![]() 109R0824L4011 | Sanyo Denki 24VDC DC Axial Fan for UPS, server and telecom equipment cooling 109R0824L4011 serves servers, UPS systems, and telecom equipment as a 80 × 80 × 25 mm DC axial fan rated at 24 VDC. High airflow is highlighted together with a high-static-pressure design. 14.7 Pa maximum pressure is the most distinctive duty-point parameter. Check cabinet ventilation planning mounting size. Focus: cabinet ventilation planning. |
24 | 80*80*25 | 38.6 | 14.7 | - | 1850 | 20 | |
![]() 109P0412H902 | Sanyo Denki 12VDC 0.84W DC Axial Fan for UPS, server and telecom equipment cooling Sanyo Denki 109P0412H902 combines a 40 × 40 × 10 mm DC axial fan platform with a 12 VDC rating for servers, UPS systems, and telecom equipment. High airflow is highlighted together with a high-static-pressure design. The 9.01 m³/h airflow figure supports its stated equipment-cooling role. Focus: cabinet ventilation planning supply requirement. |
12 | 40*40*10 | 9.01 | 41.1 | 0.84 | 6200 | 25 | |
![]() 109P0512A701 | Sanyo Denki 12VDC 2.52W DC Axial Fan for UPS, server and telecom equipment cooling The 109P0512A701 is a Sanyo Denki 12 VDC, 52 × 52 × 15 mm DC axial fan for servers, UPS systems, and telecom equipment. Series focus: high airflow and pressure. For enclosure sizing, start with the supplied duty-point values. Confirm environmental protection for the ordered version. Focus: cabinet ventilation planning static-pressure entry. |
12 | 52*52*15 | 22.2 | 69.7 | 2.52 | 6800 | 36 | |
![]() 9A0924H4011 | Sanyo Denki 24VDC 2.4W DC Axial Fan for UPS, server and telecom equipment cooling A 92 × 92 × 25 mm frame and 24 VDC rating define 9A0924H4011, a DC axial fan for servers, UPS systems, and telecom equipment. Series focus: high airflow and pressure. 44.1 Pa maximum pressure is the most distinctive duty-point parameter. Check cabinet ventilation planning volume-flow figure. Focus: cabinet ventilation planning volume-flow figure. |
24 | 92*92*25 | 85.8 | 44.1 | 2.4 | 3150 | 33 | |
![]() 9S0924F401 | Sanyo Denki 24VDC 2.16W DC Axial Fan for UPS, server and telecom equipment cooling Within servers, UPS systems, and telecom equipment, 9S0924F401 provides a 92 × 92 × 25 mm, 24 VDC DC axial fan configuration. High airflow is highlighted together with a high-static-pressure design. A listed noise figure of 27 dB is the key differentiating parameter. Check cabinet ventilation planning sound level. |
24 | 92*92*25 | 75.65 | 29.9 | 2.16 | 2650 | 27 | |
![]() 9RA0824M4001 | Sanyo Denki 24VDC 0.96W DC Axial Fan for UPS, server and telecom equipment cooling The 80 × 80 × 25 mm Sanyo Denki 9RA0824M4001 brings 24 VDC DC axial fan cooling to servers, UPS systems, and telecom equipment. High airflow is highlighted together with a high-static-pressure design. For thermal validation, start with the supplied volume-flow figure. Use current model documentation to validate protection choices. |
24 | 80*80*25 | 44.37 | 22.4 | 0.96 | 2650 | 22 | |
![]() 109R0612S401 | Sanyo Denki 12VDC 2.04W DC Axial Fan for UPS, server and telecom equipment cooling The 60 × 60 × 25 mm Sanyo Denki 109R0612S401 brings 12 VDC DC axial fan cooling to servers, UPS systems, and telecom equipment. Series focus: high airflow and pressure. Review its suffix definition during controller selection. Match the exact part number before approving a substitute. Focus: cabinet ventilation planning power demand. |
12 | 60*60*25 | 38.6 | 56.8 | 2.04 | 4600 | 33 | |
![]() 9GA0612P7G01 | Sanyo Denki 12VDC 1.92W DC Axial Fan for UPS, server and telecom equipment cooling Sanyo Denki configures 9GA0612P7G01 for servers, UPS systems, and telecom equipment as a 12 VDC DC axial fan with 60 × 60 × 15 mm dimensions. A listed input of 1.92 W is the notable efficiency-related parameter. Treat the suffix definition as a primary input to service-life planning. Use the latest specification for frequency and tolerance limits. |
12 | 60*60*15 | 41 | 80 | 1.92 | 5900 | 38 | |
![]() 109P0612S701 | Sanyo Denki 12VDC 1.8W DC Axial Fan for UPS, server and telecom equipment cooling Within servers, UPS systems, and telecom equipment, 109P0612S701 provides a 60 × 60 × 15 mm, 12 VDC DC axial fan configuration. High airflow is highlighted together with a high-static-pressure design. A listed input of 1.8 W is the notable efficiency-related parameter. Check cabinet ventilation planning cooling output. |
12 | 60*60*15 | 28.9 | 58.8 | 1.8 | 5000 | 36 | |
![]() 9RA0612P4J001 | Sanyo Denki 12VDC 4.2W DC Axial Fan for UPS, server and telecom equipment cooling The 60 × 60 × 25 mm Sanyo Denki 9RA0612P4J001 brings 12 VDC DC axial fan cooling to servers, UPS systems, and telecom equipment. High airflow is highlighted together with a high-static-pressure design. The recorded power demand should guide maintenance preparation. Review connector, alarm, and sensor options separately. |
12 | 60*60*25 | 65.96 | 129.5 | 4.2 | 7700 | 41 | |
![]() 9GA0424P6H001 | Sanyo Denki 24VDC 1.92W DC Axial Fan for UPS, server and telecom equipment cooling Sized for servers, UPS systems, and telecom equipment, Sanyo Denki 9GA0424P6H001 is a 24 VDC DC axial fan in a 40 × 40 × 20 mm frame. The 20 m³/h airflow figure supports its stated equipment-cooling role. Long-life series construction is the main characteristic stated in the supplied reference. Focus: cabinet ventilation planning. |
24 | 40*40*20 | 20 | 191 | 1.92 | 12400 | 40 |
The most reliable way to specify data Center Cooling is to work from the system, not from the catalog. Measure or calculate the airflow and pressure demand first, add the dimensional limits of the mounting position, and only then shortlist series whose curves cover your operating point with margin.
Electrical matching is the next gate. Confirm the supply voltage — 12 V, 24 V or 48 V DC for compact electronics cooling, 115 V or 230 V AC for equipment and panel cooling — and decide whether you need speed control. EC models accept PWM or 0-10 V signals and report speed through a tachometer output, which makes them the default choice for variable-airflow systems, while AC units remain a cost-effective answer for fixed-speed duty.
Then filter by environment. High ambient temperature, dust or moisture loads dictate the IP rating and bearing choice — ball bearings keep airflow and noise stable over years, while sleeve bearings suit light-duty horizontal mounting. Regulatory needs such as UL, CE and RoHS recognition should be confirmed before the shortlist goes to purchasing, together with a maximum allowed sound pressure level in dBA.
End the process by checking supply, not just specification: confirm current stock, the lead time for follow-up quantities, and obtain datasheets and dimension drawings so the mechanical interface is verified before the PO. Send us your airflow and pressure requirements and our engineers will confirm the best-matched series — 816 products are available in this category today.
The daily work of our sales engineers is built around data Center Cooling used in data center cooling, refrigeration and cold chain projects, building ventilation, telecom base stations, medical devices and industrial control cabinets — environments where a stopped fan is a stopped business process. That daily exposure to real installations is exactly what we bring back into every selection: not just reading curves, but knowing which models survive dust, heat, continuous duty and restricted service access.
A typical case: an equipment builder needed to replace an aging AC fan inside a control cabinet that could not be taken offline for more than an hour. By cross-referencing the frame dimensions, voltage and airflow curve, we supplied a current-series drop-in replacement with a matching tachometer signal, and the swap was completed during a scheduled maintenance window.
Refrigeration and cold chain customers bring us another pattern: the failed condenser fan is unavailable for weeks. Comparing diameter, speed, bearings and IP rating, we supply a functionally equivalent unit from stock so the system returns to duty the same week — the reason many service companies keep our contact number on file.
From one-piece emergency replacements to volume supply for equipment manufacturers, every enquiry is handled by the same rule: verify the parameters first, then quote — so what arrives on site is the fan the project actually needs.
Datasheets, performance curves, dimension drawings and certification files (UL, CE, RoHS where applicable) are available on request before you buy — we believe a purchase order should follow a verified selection, not replace it. For project tenders we can also provide product comparison tables that put the candidate models side by side on the parameters you care about.
Common series and mainstream voltage versions are normally in stock and can ship within a few working days; specialized or customized variants are produced to order and typically require additional production time. Send us the exact model or the required parameters and we will confirm stock, unit price and the earliest shipment date in one reply Currently 816 products in this category are listed online.
Yes. Replacement supply is one of our core services: we cross-reference the mounting dimensions, voltage, speed and performance curve of your installed unit and propose the closest current-series equivalent. Where the frame or connector differs slightly, we state the difference clearly before you order, so the replacement installs without surprises.
Bag
Bag packaging indicates that a specified quantity of product is packaged by the manufacturer in a bag, sealed pouch, or similar container and sold as a unit without repackaging. It is also used to describe kits/assortments where components are packaged in separate bags according to part number or parametric value, rather than in a compartmentalized box or similar rigid container.