Home > Products > By type > Axial Fans > 9RA0612P4J001 | Sanyo Denki 12VDC 4.2W DC Axial Fan for UPS, server and telecom equipment cooling

9RA0612P4J001 Sanyo Axial Fan

Brand :
Sanyo
Model:
9RA0612P4J001 | Sanyo Denki 12VDC 4.2W DC Axial Fan for UPS, server and telecom equipment cooling
Type:
Axial Fans
Industry:
Data Center Cooling
Description:

The 60 × 60 × 25 mm Sanyo Denki 9RA0612P4J001 brings 12 VDC DC axial fan cooling to servers, UPS systems, and telecom equipment. High airflow is highlighted together with a high-static-pressure design. The recorded power demand should guide maintenance preparation. Review connector, alarm, and sensor options separately.

Datasheet:
9RA0612P4J001 | Sanyo Denki 12VDC 4.2W DC Axial Fan for UPS, server and telecom equipment cooling Datasheet (Pdf)

Product Features

Rated Voltage(V)12
Size(mm)60*60*25
Max.Air Flow(m³/h)65.96
Max.Pressure(Pa)129.5
Input Power(W)4.2
Speed(rpm)7700
Noise(db)41

Product Features

Low Vibration Fan

9RA0612P4J001 is intended for dependable forced-air cooling in servers, storage systems and ICT equipment. This SANYO DENKI DC axial fan fits equipment designs where thermal stability affects service continuity.

The rated peak airflow of 65.96 m3/h combines with 129.5 Pa pressure capability to support useful flow after installation losses are considered. Selection should include a system-resistance review, mounting check and harness confirmation. The full model code matters because signal and lead options can differ within a series.

Measure installed sound in the final cabinet. This confirms cooling margin before volume production. Confirm the final fan curve in the assembled equipment. Preserve clear inlet and outlet space during installation.

Application Industry

Frequently Asked Questions

What supply voltage does 9RA0612P4J001 require?

The worksheet lists 12 VDC. Check polarity or AC frequency and the wiring diagram before commissioning.

Can 9RA0612P4J001 run continuously in a 24/7 system?

Verify the exact bearing, rated life, temperature range, and duty limits. The supplied family description alone does not confirm continuous operation for every suffix.

What bearing type does 9RA0612P4J001 use?

The exact bearing is not stated in the supplied row. Confirm it from the complete model suffix and current Sanyo Denki datasheet.

Which specifications define 9RA0612P4J001?

Use rated voltage, 60 × 60 × 25 mm dimensions, 65.96 m³/h airflow, 7700 rpm, and 4.2 W input for preliminary comparison.

What equipment is 9RA0612P4J001 suited to?

It is listed for servers, UPS systems, and telecom equipment. Confirm airflow, pressure, dimensions, and environmental conditions against the actual equipment.