Get Quote
Home > Products > By type > Axial Fans > 109P0612H602 | Sanyo Denki 12VDC 1.56W DC Axial Fan for UPS, server and telecom equipment cooling

109P0612H602 Sanyo Axial Fan

Brand :
Sanyo
Model:
109P0612H602 | Sanyo Denki 12VDC 1.56W DC Axial Fan for UPS, server and telecom equipment cooling
Type:
Axial Fans
Industry:
Data Center Cooling
Description:

A 60 × 60 × 20 mm frame and 12 VDC rating define 109P0612H602, a DC axial fan for servers, UPS systems, and telecom equipment. Series focus: high airflow and pressure. 31.8 Pa maximum pressure is the most distinctive duty-point parameter. Check spares strategy planning static-pressure entry. Focus: spares strategy planning static-pressure entry.

Product Features

Rated Voltage(V)12
Size(mm)60*60*20
Max.Air Flow(m³/h)24.8
Max.Pressure(Pa)31.8
Input Power(W)1.56
Speed(rpm)4200
Noise(db)31

Product Features

Pressure Cooling

The SANYO DENKI 109P0612H602 is a DC axial fan developed for servers, storage systems and ICT equipment. Its directed airflow helps remove heat from densely arranged components and supports predictable equipment temperatures.

A listed maximum airflow of 24.8 m3/h and maximum pressure of 31.8 Pa give engineers a clear basis for matching the fan to enclosure resistance. Selection should include a system-resistance review, mounting check and harness confirmation. The full model code matters because signal and lead options can differ within a series.

Review grille loss at the required duty point. This provides buyers with a traceable selection basis. Confirm the final fan curve in the assembled equipment.

Application Industry

Frequently Asked Questions

Which application details matter most for 109P0612H602?

Review ambient temperature, airflow restriction, contamination exposure, noise limit, mounting orientation, and maintenance access.

What maintenance does 109P0612H602 require?

Inspect dust buildup, airflow blockage, abnormal noise, mounting security, and wiring condition; disconnect power before service.

Can 109P0612H602 reduce total operating cost?

Compare its listed power with the required airflow, pressure, and operating hours. System-level savings depend on correct duty-point selection.

What supply voltage does 109P0612H602 require?

The worksheet lists 12 VDC. Check polarity or AC frequency and the wiring diagram before commissioning.

Can 109P0612H602 run continuously in a 24/7 system?

Verify the exact bearing, rated life, temperature range, and duty limits. The supplied family description alone does not confirm continuous operation for every suffix.

Message Form