Get Quote
Home > AC Forward

AC Forward

By type

By industry

Rated Voltage(V)

Size(mm)

Max.Air Flow(m³/h)

Max.Pressure(Pa)

Input Power(W)

Speed(rpm)

Noise(db)

Stocking Options

Environmental Options

Media

Exclude

269 results

Applied Filters

Showing
161-180
1-20 21-40 41-60 61-80 81-100 101-120 121-140 141-160 161-180 181-200 201-220 221-240 241-260 261-269
of 269
Download Table
Mfr Part # Rated Voltage(V) Size(mm) Max.Air Flow(m³/h) Max.Pressure(Pa) Input Power(W) Speed(rpm) Noise(db)
R2D190-AD18-11 | ebm-papst 460V 70W Centrifugal Fan for Automation

Built for Automation, ebm-papst R2D190-AD18-11 is a 460 V AC forward-curved centrifugal fan, documented with a documented speed of 3,050 rpm. This supports duty-point selection. Its documented data supports integration planning.

460 190 670 350 70 3050 -
R2D220-RB14-09 | ebm-papst 400V 98W Centrifugal Fan for Automation

Suited to Automation, the ebm-papst R2D220-RB14-09 is a 400 V AC forward-curved centrifugal fan, documented with 200 mm dimensions for installation planning. It supports replacement and design review.

400 200 - - 98 2450 -
R2D270-AB12-09 | ebm-papst 400V 375W Centrifugal Fan for Automation

Intended for Automation, the ebm-papst R2D270-AB12-09 is a 400 V AC forward-curved centrifugal fan, identified by a documented speed of 2,710 rpm. This enables specification-led selection.

400 270 - - 375 2710 -
R2D250-RA28-17 | ebm-papst 400V 200W Centrifugal Fan for Automation

Aimed at Automation, the ebm-papst R2D250-RA28-17 is a 400 V AC forward-curved centrifugal fan, with a focus on a documented 200 W input rating. This assists electrical and mechanical review.

400 250 - - 200 2500 -
R2D250-AM20-09 | ebm-papst 400V 170W Centrifugal Fan for Automation

Built for Automation, ebm-papst R2D250-AM20-09 is a 400 V AC forward-curved centrifugal fan, featuring a documented speed of 2,700 rpm. The data supports model-level evaluation. Its documented data supports integration planning.

400 250 - - 170 2700 -
R2D225-RA26-11 | ebm-papst 400V 200W Centrifugal Fan for Automation

Specified for Automation, the ebm-papst R2D225-RA26-11 is a 400 V AC forward-curved centrifugal fan, offering a listed acoustic value of 61 dB. This assists electrical and mechanical review.

400 225 1350 550 200 2700 61
R2D225-AV02-15 | ebm-papst 400V 115W Centrifugal Fan for Automation

Intended for Automation, the ebm-papst R2D225-AV02-15 is a 400 V AC forward-curved centrifugal fan, identified by a listed airflow of 1,195 m³/h. It gives engineers a clear comparison point.

400 225 1195 400 115 2650 -
R2D225-AV02-12 | ebm-papst 415V 165W Centrifugal Fan for Automation

Used in Automation, the ebm-papst R2D225-AV02-12 is a 415 V AC forward-curved centrifugal fan, whose supplied data highlights a documented speed of 3,000 rpm. The rating aids system-fit checks.

415 225 1335 450 165 3000 -
R2D225-AV02-11 | ebm-papst 400V 160W Centrifugal Fan for Automation

Engineered around Automation, the ebm-papst R2D225-AV02-11 is a 400 V AC forward-curved centrifugal fan, with a focus on a documented speed of 2,950 rpm. This assists electrical and mechanical review.

400 225 - - 160 2950 -
R2D225-AP02-09 | ebm-papst 400V 160W Centrifugal Fan for Automation

Engineered around Automation, the ebm-papst R2D225-AP02-09 is a 400 V AC forward-curved centrifugal fan, centered on a documented speed of 2,950 rpm. The value helps verify equipment fit.

400 225 1110 466 160 2950 -
R2D225-AG02-10 | ebm-papst 400V 250W Centrifugal Fan for Automation

Used in Automation, ebm-papst R2D225-AG02-10 is a 400 V AC forward-curved centrifugal fan, featuring a documented speed of 3,000 rpm. The data supports model-level evaluation. Its documented data supports integration planning.

400 225 1395 400 250 3000 -
R2D220-AB02-10 | ebm-papst 380V 75W Centrifugal Fan for Automation

Configured for Automation, the ebm-papst R2D220-AB02-10 is a 380 V AC forward-curved centrifugal fan, with a focus on a documented 75 W input rating. This assists electrical and mechanical review.

380 220 - - 75 2800 -
R2D190-AC08-10 | ebm-papst 415V 58W Centrifugal Fan for Automation

Specified for Automation, ebm-papst R2D190-AC08-10 is a 415 V AC forward-curved centrifugal fan, with a documented 58 W input rating. It provides a practical sizing reference. Its documented data supports integration planning.

415 190 630 - 58 2700 -
R2D180-AL10-18 | ebm-papst 400V 105W Centrifugal Fan for Automation

Specified for Automation, the ebm-papst R2D180-AL10-18 is a 400 V AC forward-curved centrifugal fan, offering 180 mm dimensions for installation planning. It gives engineers a clear comparison point.

400 180 645 240 105 2650 -
R2D160-AC02-13 | ebm-papst 400V 260W Centrifugal Fan for Spindle

Suited to Spindle, the ebm-papst R2D160-AC02-13 is a 400 V AC forward-curved centrifugal fan, whose supplied data highlights 160 mm dimensions for installation planning. It provides a practical sizing reference.

400 160 - - 260 2100 -
G2D160-AF28-38 | ebm-papst 480V 365W AC Centrifugal Blower for HVAC

A 480 V AC centrifugal blower for hvac, G2D160-AF28-38 has a clearly defined selection profile. Among the supplied ratings, a 365 W input rating with 750 Pa pressure clearly differentiates this variant.

480 160 615 750 365 2820 -
G2D180-AE02-01 | ebm-papst 400V 385W AC Centrifugal Blower for HVAC

Targeting hvac, G2D180-AE02-01 pairs 400 V operation with a AC centrifugal blower layout. 2,850 rpm operation with a 385 W input rating is its clearest differentiator in the supplied data.

400 180 - - 385 2850 -
G2D180-AE02-26 | ebm-papst 400V 385W AC Centrifugal Blower for HVAC

In hvac, G2D180-AE02-26 serves as a 400 V AC centrifugal blower. The supplied specifications highlight IP44 protection with 2,850 rpm operation. It supports exact-model comparison for OEM sourcing and replacement work.

400 180 - - 385 2850 -
G2D180-AE02-14 | ebm-papst 230V 420W AC Centrifugal Blower for HVAC

G2D180-AE02-14 is specified as a 230 V AC centrifugal blower for hvac. For selection, its most distinctive listed attribute is IP44 protection with a 420 W input rating. It supports exact-model comparison for OEM sourcing.

230 180 - 300 420 2370 -
G2D160-AF02-01 | ebm-papst 400V 335W AC Centrifugal Blower for HVAC

Designed around hvac, G2D160-AF02-01 uses a 400 V AC centrifugal blower platform. Its standout data point is IP44 protection with 700 Pa pressure. It supports exact-model comparison for OEM sourcing and replacement work.

400 160 585 700 335 2550 -
Showing
161-180
1-20 21-40 41-60 61-80 81-100 101-120 121-140 141-160 161-180 181-200 201-220 221-240 241-260 261-269
of 269
1 2 ... 5 6 7 8 9 10 11 12 13 14
GO page

About AC Forward

AC forward curved centrifugal fans use impellers with blade tips angled in the direction of rotation, which creates a velocity multiplier effect — these fans can produce very high airflow rates at moderate static pressures relative to their physical size and motor power. Forward curved centrifugal fans are the preferred choice for HVAC air handling units, where large volume airflow is needed with moderate duct resistance, and for applications requiring compact dimensions relative to airflow output. They are also widely used in fume extraction, dust collection systems with light loading, and industrial process ventilation. The main trade-off compared to backward curved impellers is lower aerodynamic efficiency — forward curved designs typically operate at 55-65 percent efficiency versus 70-85 percent for backward curved types. Important specification parameters include impeller diameter, motor speed (RPM), airflow (m3/h or CFM), static pressure (Pa or mm WG), and sound power level. Leading manufacturers supplying AC forward curved centrifugal fans include ebm-papst (in its A series), ZIEHL-ABEGG, Rosenberg, and SODECA. Hengrui offers competitive factory-direct pricing and engineering consultation for AC forward curved fan selection.

How to Select the Right AC Forward

Before comparing models of AC Forward, write down the real operating requirements: required airflow, system static pressure, available installation space and the electrical supply on site. A selection that ignores any of these four factors usually ends in returned goods or on-site retrofits.

Voltage and control define the shortlist. Standard options include 12/24/48 V DC and 115/230 V AC; for applications where operating points move, EC fans with PWM or 0-10 V input give precise speed control, and a tach signal provides the feedback many safety systems require.

Environmental conditions eliminate unsuitable models faster than any catalog filter. Check the ambient temperature range, required IP protection for dust and moisture, and the expected service life — ball-bearing units hold their noise and airflow figures far longer than sleeve-bearing designs in vertical or high-temperature positions. If the equipment must ship into regulated markets, verify UL, CE and RoHS compliance at this stage, and set a realistic noise target in dBA so acoustic requirements do not surface after installation.

Close the selection by de-risking the order: verify stock levels, confirm production lead time, and request datasheets plus dimension drawings for the final candidates so the mounting holes and connectors are checked before purchase. Share your operating point with us and we will validate the fit 269 products in this category are ready for comparison.

Typical Applications and Use Cases for AC Forward

Across our project record, AC Forward are specified wherever equipment must stay cool and air must keep moving: data centers and server rooms, commercial refrigeration, air handling and ventilation systems, telecom and battery cabinets, industrial machinery, and power electronics in the new-energy sector. What these projects share is a simple truth — the fan is small in cost but decisive for uptime, so it deserves the same engineering attention as the equipment it protects.

In a recent retrofit project, a customer's cooling unit had to keep running while its worn fan was exchanged. We identified a current-series replacement with identical mounting dimensions and an equivalent airflow-pressure curve, confirmed the tach output compatibility, and the installation was finished within a single maintenance window.

A second frequent case is refrigeration service: a condenser or evaporator fan fails and the exact original model is on long lead time. Instead of waiting, we check bearing type, IP rating, blade diameter and speed, then offer an equivalent that restores capacity immediately — one of the most common ways our stock protects cold chain operations.

New builds and replacement projects on ebmpapst equipment follow the same path at our company: you send the required airflow, pressure and dimensions; we respond with a shortlist, performance curves and firm delivery dates.

Frequently Asked Questions About Buying AC Forward

Can you replace my existing AC Forward from another supplier or a discontinued model?

Yes. Replacement supply is one of our core services: we cross-reference the mounting dimensions, voltage, speed and performance curve of your installed unit and propose the closest current-series equivalent. Where the frame or connector differs slightly, we state the difference clearly before you order, so the replacement installs without surprises.

Can I order a single piece or request a sample before a bulk purchase?

Single-piece orders and samples are welcome — many customers validate one unit in their system before committing to volume. There is no minimum order quantity for standard stock models, and the sample price is deducted from the bulk order in most repeat purchases. Tell us the quantity you plan to use and we will quote both scenarios.

Do you support customized or OEM versions of AC Forward?

Yes. Beyond catalogue models we can discuss modified lead wires, connectors, speed curves, IP upgrades or private-label packaging for OEM projects. Customization usually starts from a defined annual quantity; our engineers will review your requirement and confirm feasibility, tooling cost and lead time before any commitment.

Bag

Bag packaging indicates that a specified quantity of product is packaged by the manufacturer in a bag, sealed pouch, or similar container and sold as a unit without repackaging. It is also used to describe kits/assortments where components are packaged in separate bags according to part number or parametric value, rather than in a compartmentalized box or similar rigid container.