Get Quote
Home > EC Backward

EC Backward

By type

By industry

Rated Voltage(V)

Size(mm)

Max.Air Flow(m³/h)

Max.Pressure(Pa)

Input Power(W)

Speed(rpm)

Noise(db)

Stocking Options

Environmental Options

Media

Exclude

386 results

Applied Filters

Showing
381-386
1-20 21-40 41-60 61-80 81-100 101-120 121-140 141-160 161-180 181-200 201-220 221-240 241-260 261-280 281-300 301-320 321-340 341-360 361-380 381-386
of 386
Download Table
Mfr Part # Rated Voltage(V) Size(mm) Max.Air Flow(m³/h) Max.Pressure(Pa) Input Power(W) Speed(rpm) Noise(db)
K3G250-AV29-B4 | ebm-papst 1~ 200-277V 750W EC Centrifugal Fan for Renewable Energy

Selected for Renewable Energy, the ebm-papst K3G250-AV29-B4 is a 200-277V EC backward-curved centrifugal fan, with a focus on a listed acoustic value of 57 dB. This assists electrical and mechanical review.

1~ 200-277 250 3120 1050 750 3450 57
K3G250-AV29-B2 | ebm-papst 1~ 200-277V 750W EC Centrifugal Fan for Data Center Cooling

Engineered around Data Center Cooling, the ebm-papst K3G250-AV29-B2 is a 200-277V EC backward-curved centrifugal fan, documented with a documented speed of 3,450 rpm. This supports duty-point selection.

1~ 200-277 250 3120 1050 750 3450 63
K3G190-RD45-03 | ebm-papst 230V 169W EC Centrifugal Fan for Battery Cooling

Designed for Battery Cooling, the ebm-papst K3G190-RD45-03 is a 230 V EC backward-curved centrifugal fan, defined by a documented speed of 4,120 rpm. The value helps verify equipment fit.

230 190 524 - 169 4120 -
K3G097-AK34-43 | ebm-papst 26V 325W EC Centrifugal Fan for Cabinet Cooling

Aimed at Cabinet Cooling, the ebm-papst K3G097-AK34-43 is a 26 V EC backward-curved centrifugal fan, centered on a documented speed of 3,600 rpm. This helps guide installation planning.

26 97 1195 650 325 3600 -
K1G220-AB73-11 | ebm-papst 48V 110W EC Centrifugal Fan for Industrial Cooling

Built for Industrial Cooling, the ebm-papst K1G220-AB73-11 is a 48 V EC backward-curved centrifugal fan, offering a documented 110 W input rating. This enables specification-led selection.

48 220 - - 110 2880 -
K1G165-AA01-05 | ebm-papst 24V 19W EC Centrifugal Fan for Cabinet Cooling

Intended for Cabinet Cooling, the ebm-papst K1G165-AA01-05 is a 24 V EC backward-curved centrifugal fan, defined by a documented 19 W input rating. This helps guide installation planning.

24 165 - - 19 2830 55
Showing
381-386
1-20 21-40 41-60 61-80 81-100 101-120 121-140 141-160 161-180 181-200 201-220 221-240 241-260 261-280 281-300 301-320 321-340 341-360 361-380 381-386
of 386
1 2 ... 11 12 13 14 15 16 17 18 19 20
GO page

About EC Backward

The EC Backward category represents ebm-papst's comprehensive selection of electronically commutated centrifugal fans with backward-curved impellers. With 357 products ranging from compact 24V units to high-performance 48V models, this is the largest single sub-collection within the ebm-papst catalog.

EC backward curved fans deliver exceptional static pressure and airflow efficiency, making them ideal for applications requiring medium to high pressure — including data center cabinet cooling, inverter drives, industrial machinery ventilation, and telecommunications equipment. The product lineup covers voltage inputs from 24V to 48V and power outputs from 19W up to 325W, with a broad spectrum of impeller diameters to match different system resistance requirements.

Every model in this category benefits from ebm-papst's GreenTech EC technology, which reduces energy consumption by up to 50% compared to conventional AC fans while maintaining precise speed control and extended service life.

How to Select the Right EC Backward

Choosing the right EC Backward starts with the operating point rather than the model name. Define the airflow you actually need in CFM or m³/h and the static pressure the fan must overcome, then look for units whose performance curves pass through that point with a safety margin instead of sitting at the edge of the curve.

Pay attention to the electrical details early. DC fans typically run on 12/24/48 V and integrate easily with control boards, while AC fans suit 115/230 V fixed-speed installations. If the airflow must change with load, choose EC technology with PWM or analog control and, where monitoring matters, a tachometer output so the controller can detect fan failure.

Environment and compliance come next. Match the IP rating to dust and moisture exposure, prefer ball bearings wherever the fan runs hot, vertically or around the clock, and confirm certifications — UL, CE, RoHS — against your destination market. Setting the acoustic limit in dBA early prevents late-stage redesign when the first unit proves too loud.

Finally, compare candidates on total delivery risk, not only on price: confirm stock for the quantity you need, check the lead time for the next batch, and ask for datasheets and dimension drawings before committing. Our team cross-checks curves, dimensions and electrical data for you before quotation There are currently 386 items in this category ready to compare.

Typical Applications and Use Cases for EC Backward

EC Backward appear in almost every sector where heat or stale air must be moved reliably. Typical environments include server rooms and data centers, refrigeration condensers and cold-store evaporators, HVAC air handling units, telecom cabinets, medical and laboratory equipment, welding and CNC machine enclosures, and renewable-energy power cabinets. In each of these settings the fan is a critical component: its failure stops production, damages stored goods or forces expensive emergency downtime.

One recurring scenario comes from control cabinet retrofits: the original fan is obsolete, the mounting hole pattern cannot change, and downtime is measured in hours. We match the old unit against current series by frame size, airflow and noise, propose the closest drop-in alternative, and ship with a datasheet that lets the electrician connect it without redesign.

For cold storage operators the pain is simple: a failed evaporator or condenser fan must be replaced now, not after a six-week import cycle. Matching blade diameter, speed and protection class against stocked equivalents lets us restore cooling capacity within days, which is why replacement supply has become a core part of this category for us.

Whether the project involves new equipment or the replacement of installed ebmpapst units, the workflow is the same: send us the operating point and constraints, and we return a validated selection with datasheets, curves and a clear lead time.

Frequently Asked Questions About Buying EC Backward

Do you have EC Backward in stock and how fast can you deliver?

Common series and mainstream voltage versions are normally in stock and can ship within a few working days; specialized or customized variants are produced to order and typically require additional production time. Send us the exact model or the required parameters and we will confirm stock, unit price and the earliest shipment date in one reply Currently 386 products in this category are listed online.

Can you replace my existing EC Backward from another supplier or a discontinued model?

Yes. Replacement supply is one of our core services: we cross-reference the mounting dimensions, voltage, speed and performance curve of your installed unit and propose the closest current-series equivalent. Where the frame or connector differs slightly, we state the difference clearly before you order, so the replacement installs without surprises.

Can I order a single piece or request a sample before a bulk purchase?

Single-piece orders and samples are welcome — many customers validate one unit in their system before committing to volume. There is no minimum order quantity for standard stock models, and the sample price is deducted from the bulk order in most repeat purchases. Tell us the quantity you plan to use and we will quote both scenarios.

Bag

Bag packaging indicates that a specified quantity of product is packaged by the manufacturer in a bag, sealed pouch, or similar container and sold as a unit without repackaging. It is also used to describe kits/assortments where components are packaged in separate bags according to part number or parametric value, rather than in a compartmentalized box or similar rigid container.