AFB0712HHB-F00 is a 12 VDC axial fan for servers, data-communications equipment, control cabinets. Its main supplied feature is 52.27 Pa maximum pressure stated for this model. It also lists a 70x70x15 mm size specified in the upload data. Review performance curve for equipment design.
| Rated Voltage(V) | 12 |
|---|---|
| Size(mm) | 70x70x15 |
| Max.Air Flow(m³/h) | 63.78 |
| Max.Pressure(Pa) | 52.27 |
| Input Power(W) | 3.12 |
| Speed(rpm) | 4300 |
| Noise(db) | 38.5 |
Delta AFB0712HHB-F00 is a DC axial fan selected for data centers and communication assembly, where controlled air movement protects operating margin in compact or continuously loaded assembly.
The 4300 rpm speed and 38.5 dB sound entry help maintain assembly-level thermal and acoustic review.
Axial air movement is appropriate where volume flow is the primary requirement and the completed installation does not impose excessive resistance.
Assembly designers gain a traceable heat removal specification that can be reviewed by engineering, purchasing and maintenance teams. Confirm the exact operating point before production release. Preserve the specified air movement direction during assembly. Review the approved electrical interface for the complete suffix.
When production in servers and data-communication hardware, AFB0712HHB-F00 cools computing and network assemblies within the available hardware space. The application needs predictable ventilation flow because dense layouts restrict natural convection and heat spreading.
Hardware serving power supplies, inverters and control cabinets can integrate Delta AFB0712HHB-F00; the unit cools power modules and controls. The application needs predictable ventilation flow because dense layouts restrict natural convection and heat spreading.
Delta AFB0712HHB-F00 serves industrial automation assembly; its primary application is to ventilates drives and production electronics. System developers should verify mounting, air movement direction and system resistance to preserve the intended application value.
For assembly in medical and laboratory instruments, Delta AFB0712HHB-F00 acts as a heat removal component that cools enclosed instrument electronics. Forced-air heat removal enables assembly availability during long duty cycles and repeated load changes.
The supplied files do not establish a universal 24/7 duty rating. Validate ambient conditions, duty cycle, protection, and maintenance requirements for continuous use.
The supplied application data covers servers, data-communications equipment, control cabinets. Confirm the installation's airflow, pressure, space, and electrical requirements.
Match the complete model code, voltage, dimensions, mounting arrangement, airflow direction, performance point, and control interface to the equipment.
The upload row lists RoHS compliance, but no additional exact-model certification is confirmed in the supplied feature record.
Verify the listed size, mounting pattern, fan housing or nozzle arrangement, airflow direction, and service clearance against the equipment drawing.
Speed-control support is not stated for this exact item in the supplied sources. Confirm the motor and controller version before specifying control hardware.

A 1.44 W input makes AFB0624MB a lower-input entry among the listed 24VDC axial fan fans. For server and power-supply ventilation, it provides a 60 x 60 x 15 mm format with a specified 4000 rpm rotor.
Read More
AFB0612HH-A combines a 5000 rpm rotor with a 12VDC axial fan motor for server and power-supply cooling. Its listed 2.04 W input and 74 Pa maximum static pressure accompany a 60 x 60 x 25.4 mm frame.
Read More
AFB1224GHE-C is a 24VDC axial fan for server chassis, with 409.7 m3/h listed maximum airflow. Its 27.6 W input differs from the 12VDC GHE entry; retain the -C suffix when checking connector and control configuration.
Read More
AFB0912HH supports storage-enclosure cooling with a 12VDC axial fan design. At 3200 rpm and 3 W listed input, it represents a distinct operating choice among the supplied 92 mm fans, with a specified 25.4 mm depth.
Read More
Server chassis with space for a 38 mm-deep fan can consider AFB0824SHE, an 80 mm axial model powered by 24VDC. Its listed airflow ceiling is 123.6 m3/h, a useful comparison point for enclosure ventilation designs.
Read More
A deeper 70 x 70 x 38 mm frame distinguishes AFB0712VHE for server and power-supply cooling. The 12VDC axial fan lists 7000 rpm operation and 216.7 Pa maximum pressure, with an 8.4 W input rating.
Read More