8315100563 VWCD060WJDFS is a 24 VDC compact axial fan for industrial automation, power supplies. Its main supplied feature is 45 m³/h maximum airflow stated for this model. It also lists a 60*60*25 mm size specified in the upload data. Review system resistance for air-system design. Check the exact variant before ordering.
| Rated Voltage(V) | 24 |
|---|---|
| Size(mm) | 60*60*25 |
| Max.Air Flow(m³/h) | 45 |
| Max.Pressure(Pa) | 105 |
| Input Power(W) | 1.5 |
| Speed(rpm) | 5300 |
ebm-papst developed 8315100563 VWCD060WJDFS in a DC space-efficient axial fan configuration applicable to automation and electronic manufacturing equipment, where steady airflow contributes to equipment availability.
The thermal role must be validated from the approved datasheet because the reference does not establish every configuration detail.
The listed 24 V supply and 1.5 W input give control-circuit designers a defined basis for power and interface planning.
Equipment designers gain a traceable thermal control specification that can be reviewed by engineering, purchasing and maintenance teams. Validate sound and temperature in the finished chassis. Keep the model reference unchanged in replacement documentation.
Its advantage should be judged from the matched series feature, exact size, electrical rating, and available performance data rather than from a generic fan comparison.
The supplied files do not establish a universal 24/7 duty rating. Validate ambient conditions, duty cycle, protection, and maintenance requirements for continuous use.
Check electrical supply, mounting clearance, fasteners, airflow direction, guards, wiring, and access for service before installation.
Match the complete model code, voltage, dimensions, mounting arrangement, airflow direction, performance point, and control interface to the equipment.
The upload sheet marks the item as In Stock, but available quantity should be confirmed when the order is placed.
Verify the listed size, mounting pattern, fan housing or nozzle arrangement, airflow direction, and service clearance against the equipment drawing.