8315100592 VWCD060WHDGS is a 12 VDC compact axial fan for industrial automation, power supplies. Its main supplied feature is a 60*60*25 mm size specified in the upload data. It also lists 46 m³/h maximum airflow stated for this model. Review fan selection for air-system design. Check the exact variant before ordering.
| Rated Voltage(V) | 12 |
|---|---|
| Size(mm) | 60*60*25 |
| Max.Air Flow(m³/h) | 46 |
| Max.Pressure(Pa) | 105 |
| Input Power(W) | 1.2 |
| Speed(rpm) | 5300 |
Installation makers serving automation and electronic manufacturing installation can integrate ebm-papst 8315100592 VWCD060WHDGS as a DC space-efficient axial fan for directed ventilation and internal element-level generated heat removal.
The available reference identifies the product category but does not confirm model-specific construction, bearing, control signal or protection details.
The listed 12 V supply and 1.2 W input give electromechanical designers a defined basis for power and interface planning.
A documented installation-level test links the selected fan to measurable thermal control value instead of isolated catalogue figures. Confirm the exact operating point before production release. Preserve the specified airflow direction during assembly.
The upload row lists RoHS compliance, but no additional exact-model certification is confirmed in the supplied feature record.
Verify the listed size, mounting pattern, fan housing or nozzle arrangement, airflow direction, and service clearance against the equipment drawing.
Check supply voltage, controller signals, blocked airflow, contamination, abnormal noise, rotation, and the equipment operating point before replacing the unit.
No model-specific maintenance interval is supplied. Keep the airflow path clean, inspect mounting and electrical connections, and follow the exact product instructions.
The supplied row lists 46 m³/h airflow, 105 Pa pressure, 1.2 W input, 5300 rpm. Compare these values with the real system operating point, not only the free-air rating.
The supplied files do not establish a universal 24/7 duty rating. Validate ambient conditions, duty cycle, protection, and maintenance requirements for continuous use.