Get Quote
Home > Products > By type > Compact Fans > 8414NGML | ebm-papst 24VDC 1.2W DC Compact Fan for servers and data communications equipment

8414NGML ebm-papst Compact Fan

Brand :
ebmpapst
Model:
8414NGML | ebm-papst 24VDC 1.2W DC Compact Fan for servers and data communications equipment
Type:
Compact Fans
Industry:
Data Center Cooling
Description:

8414NGML is a 24 VDC compact axial fan for servers, data-communications equipment, control cabinets. Its main supplied feature is 1.2 W input power for the listed electrical version. It also lists a 80*80*25 mm size specified in the upload data. Review motor interface for equipment design.

Product Features

Rated Voltage(V)24
Size(mm)80*80*25
Max.Air Flow(m³/h)45
Max.Pressure(Pa)16
Input Power(W)1.2
Speed(rpm)2050

Product Features

Space Saving Fan

8414NGML gives designers of data centers and communication hardware a ebm-papst DC constrained-space axial fan option for routing air through limited spaces and thermally active sections.

Application validation should include realistic filters, grilles and neighboring components because these elements influence delivered moving air.

A constrained-space axial structure provides a practical forced-air cooling path for dense devices, short internal passages and localized thermal zones.

Listed moving air of 45 m3/h and pressure of 16 Pa provide starting points for duty-point evaluation in the completed application. Check environmental limits in the original product data. Confirm the exact operating point before production release. Preserve the specified moving air direction during assembly.

Application Industry

Frequently Asked Questions

Does 8414NGML require a separate controller?

The supplied sources do not confirm an integrated controller. Verify the exact electrical variant and control requirement before ordering.

Can 8414NGML be considered for continuous operation?

The supplied files do not establish a universal 24/7 duty rating. Validate ambient conditions, duty cycle, protection, and maintenance requirements for continuous use.

What should be checked before installing 8414NGML?

Check electrical supply, mounting clearance, fasteners, airflow direction, guards, wiring, and access for service before installation.

Which application details should be confirmed before ordering 8414NGML?

Confirm the target equipment, operating point, ambient conditions, installation space, electrical supply, controls, protection, quantity, and required delivery date.

Which certifications are documented for 8414NGML?

The upload row lists RoHS compliance, but no additional exact-model certification is confirmed in the supplied feature record.

What mounting details matter for 8414NGML?

Verify the listed size, mounting pattern, fan housing or nozzle arrangement, airflow direction, and service clearance against the equipment drawing.

Message Form