A4E400-AP02-01 is a 230 VAC axial fan for data-communications equipment, heat pumps, ventilation systems. Its main supplied feature is a 400 mm size specified in the upload data. It also lists 4950 m³/h maximum airflow stated for this model. Review housing geometry for compatibility checking.
| Rated Voltage(V) | 230 |
|---|---|
| Size(mm) | 400 |
| Max.Air Flow(m³/h) | 4950 |
| Max.Pressure(Pa) | 75 |
| Input Power(W) | 240 |
| Speed(rpm) | 1700 |
| Noise(db) | 71 |
Application makers serving air-handling, HVAC and refrigeration application can integrate ebm-papst A4E400-AP02-01 as an AC axial fan for directed ventilation and device-level accumulated heat removal.
This helps project engineers translate moving air into lower device thermal state, steadier function and a more repeatable application integration plan.
A coordinated impeller, frame and motor path helps convert powered input into useful forced-air cooling moving air without unnecessary flow disturbance.
The 1700 rpm speed and 71 dB sound entry aid application-level thermal and acoustic review. Confirm the exact operating point before production release. Preserve the specified moving air direction during assembly. Review the approved powered interface for the complete suffix.
The ebm-papst AC axial fan A4E400-AP02-01 addresses thermal demand in HVAC and ventilation systems by helping to provide supply or exhaust airflow. These systems operate with concentrated heat loads that can create local hot spots without ongoing circulation.
As part of refrigeration and condenser assembly, ebm-papst A4E400-AP02-01 performs a defined excess heat removal task and moves air across refrigeration coils. Sustained duty requires an air movement component that integrates cleanly with the assembly architecture.
For machinery in generated heat exchangers, ebm-papst A4E400-AP02-01 acts as a temperature management part that moves air across transfer surfaces. A defined air route aids repeatable thermal behavior across production units and service replacements.
For equipment in generated heat-pump systems, ebm-papst A4E400-AP02-01 acts as a working temperature management assembly that moves air through exchange sections. The finished working temperature management flow path should remain clear during installation and routine maintenance.
The matched source highlights a 400 mm size specified in the upload data. Compare that point together with the listed electrical and dimensional data.
The supplied row lists 4950 m³/h airflow, 75 Pa pressure, 240 W input, 1700 rpm, 71 dB. Compare these values with the real system operating point, not only the free-air rating.
It may be evaluated for high-reliability cooling using the supplied parameters, but duty cycle, redundancy, ambient limits, and protection must be confirmed at system level.
The supplied application data covers data-communications equipment, heat pumps, ventilation systems. Confirm the installation's airflow, pressure, space, and electrical requirements.
Confirm the target equipment, operating point, ambient conditions, installation space, electrical supply, controls, protection, quantity, and required delivery date.
The upload sheet marks the item as In Stock, but available quantity should be confirmed when the order is placed.

A4E350-AP06-33 is a 230 VAC axial fan for data-communications equipment, heat pumps, ventilation systems. Its main supplied feature is 3110 m³/h maximum airflow stated for this model. It also lists a 350 mm size specified in the upload data. Review ventilation duty for air-system design.
Read MoreA4E450-AP01-01 is a 230 VAC axial fan for data-communications equipment, heat pumps, ventilation systems. Its main supplied feature is 355 W input power for the listed electrical version. It also lists a 450 mm size specified in the upload data. Review controller compatibility for compatibility checking.
Read More
Used in HVAC Ventilation, ebm-papst A2D300-AP02-02 is a 400 V AC axial fan, defined by a listed airflow of 3,350 m³/h. The data helps compare W-series variants. Its documented data supports integration planning.
Read More
A4E300-AS72-01 is a 230 VAC axial fan for data-communications equipment, heat pumps, ventilation systems. Its main supplied feature is 80 W input power for the listed electrical version. It also lists a 300 mm size specified in the upload data. Review performance curve for cabinet planning.
Read More
A2E200-AF02-02 is a 230 VAC axial fan for data-communications equipment, heat pumps, ventilation systems. Its main supplied feature is a 200 mm size specified in the upload data. It also lists 830 m³/h maximum airflow stated for this model. Review operating point for cabinet planning.
Read More
A2E300-AC47-01 is a 230 VAC axial fan for data-communications equipment, heat pumps, ventilation systems. Its main supplied feature is 190 W input power for the listed electrical version. It also lists a 300 mm size specified in the upload data. Review control method for cabinet planning.
Read More