AB05012DX200300(0APXL1) is a 12 VDC centrifugal fan for servers, medical equipment, laboratory equipment. Its main supplied feature is 2.72 m³/h maximum airflow stated for this model. It also lists a 50*50*20 mm size specified in the upload data. Review airflow path for installation planning.
| Rated Voltage(V) | 12 |
|---|---|
| Size(mm) | 50*50*20 |
| Max.Air Flow(m³/h) | 2.72 |
| Input Power(W) | 0.96 |
| Speed(rpm) | 3700 |
| Noise(db) | 25.6 |
AB05012DX200300(0APXL1) gives designers of data centers and communication system a ebm-papst DC blower fan option for routing air through limited spaces and thermally active sections.
The listed ventilation flow of 2.72 m3/h remains subject to the resistance and recirculation of the production installation.
Its directed outlet enables cooling air to reach a specific heat source when a straight-through axial path is impractical.
The result is a practical cooling component for manufacturers balancing thermal performance, installation space and lifecycle service. Check environmental limits in the original product data. Confirm the exact operating point before production release. Preserve the specified ventilation flow direction during assembly.
Applied to servers and data-communication hardware, ebm-papst model AB05012DX200300(0APXL1) cools computing and network assemblies. This approach helps manufacturers balance temperature management effectiveness, enclosure space and lifecycle maintenance.
OEM designs for power supplies, inverters and control cabinets use AB05012DX200300(0APXL1) where a DC blower fan must cools power modules and controls. The result contributes to repeatable running while keeping the forced-air cooling function understandable for future service work.
AB05012DX200300(0APXL1) aids office, imaging and household appliances by using its DC blower fan format to removes appliance heat. The result aids consistent operation while keeping the thermal management function understandable for future service work.
OEM designs for medical and laboratory instruments use AB05012DX200300(0APXL1) where a DC blower fan must cools enclosed instrument electronics. Maintaining clear inlet and outlet space helps the integrated assembly realize the expected heat removal benefit.
The supplied files do not establish a universal 24/7 duty rating. Validate ambient conditions, duty cycle, protection, and maintenance requirements for continuous use.
The supplied application data covers servers, medical equipment, laboratory equipment. Confirm the installation's airflow, pressure, space, and electrical requirements.
No quantified cost-saving claim is supplied for this exact item. Compare energy use, controls, service needs, and purchase cost using the required duty point.
The product is classified as a centrifugal fan. Use the full model code because nearby variants can differ in motor, mounting, and controls.
The upload row lists 12 VDC. Confirm phase, frequency, terminals, and local supply conditions before wiring.
The upload row lists 25.6 dB. Confirm the measurement condition and compare noise at the intended operating point.