AD0412HB-G70 is a 12 VDC axial fan for servers, data-communications equipment, control cabinets. Its main supplied feature is axial airflow intended for low-to-moderate system resistance. It also lists a 40*40*10 mm size specified in the upload data. Review pressure requirement for installation planning.
| Rated Voltage(V) | 12 |
|---|---|
| Size(mm) | 40*40*10 |
| Max.Air Flow(m³/h) | 3.94 |
| Input Power(W) | 1.2 |
| Speed(rpm) | 6000 |
| Noise(db) | 25 |
Model AD0412HB-G70 is positioned as the ebm-papst DC axial fan for data centers and communication hardware, supporting air movement where passive convection cannot maintain the required temperature margin.
Integrated approval should consider mounting, connector or lead arrangement, air movement direction and access for future service.
The axial layout favors direct air delivery when the surrounding grille, inlet clearance and outlet path are correctly engineered.
The listed air movement of 3.94 m3/h remains subject to the resistance and recirculation of the integrated installation. Check environmental limits in the original product data. Confirm the exact operating point before production release. Preserve the specified air movement direction during assembly.
Within servers and data-communication hardware, AD0412HB-G70 cools computing and network assemblies as a ebm-papst DC axial fan. The result aids consistent service while keeping the temperature management function understandable for future service work.
The thermal management role of ebm-papst AD0412HB-G70 in power supplies, inverters and control cabinets is to cools power modules and controls. Sustained operation requires an air delivery component that integrates cleanly with the machinery architecture.
ebm-papst AD0412HB-G70 is used in industrial automation installation, where the DC axial fan ventilates drives and production electronics. These systems operate with concentrated heat loads that can create local hot spots without continuous circulation.
When assembled in medical and laboratory instruments, AD0412HB-G70 cools enclosed instrument electronics within the available installation space. Forced-air thermal control aids installation availability during long duty cycles and repeated load changes.
The upload row lists RoHS compliance, but no additional exact-model certification is confirmed in the supplied feature record.
Verify the listed size, mounting pattern, fan housing or nozzle arrangement, airflow direction, and service clearance against the equipment drawing.
Speed-control support is not stated for this exact item in the supplied sources. Confirm the motor and controller version before specifying control hardware.
No guaranteed lead time is provided in the supplied sources. Confirm current stock, required quantity, production schedule, and shipping date with the supplier.
The supplied sources do not confirm an integrated controller. Verify the exact electrical variant and control requirement before ordering.
Compare the full model suffix, voltage, size, motor or controller type, mounting, airflow, pressure, power, speed, and protection; do not copy data from a similar model.