Get Quote
Home > Products > By type > Centrifugal Fans > K3G200-AG16-I3 | ebm-papst 230VAC 450W EC Centrifugal Fan for air handling and HVAC systems

K3G200-AG16-I3 ebm-papst Centrifugal Fan

Brand :
ebmpapst
Model:
K3G200-AG16-I3 | ebm-papst 230VAC 450W EC Centrifugal Fan for air handling and HVAC systems
Type:
Centrifugal Fans
Industry:
HVAC & Ventilation
Description:

K3G200-AG16-I3 is a 230 VAC centrifugal fan for electronic equipment, heat pumps, equipment cooling. Its main supplied feature is a compact construction intended to simplify equipment integration. It also lists a 200 mm size specified in the upload data. Review duct connection for procurement comparison.

Product Features

Rated Voltage(V)230
Size(mm)200
Max.Air Flow(m³/h)1500
Max.Pressure(Pa)850
Input Power(W)450
Speed(rpm)5390
Noise(db)79

Product Features

Stable Air Delivery

ebm-papst K3G200-AG16-I3 addresses equipment thermal control in air-handling, HVAC and refrigeration equipment with an EC centrifugal fan architecture suited to repeatable installation and service identification.

The 5390 rpm speed and 79 dB sound entry reinforce equipment-level thermal and acoustic review.

Air enters axially and leaves radially, allowing the fan to develop useful pressure for ducts, filters, coils and restricted equipment passages.

The result is a practical thermal control component for manufacturers balancing thermal performance, installation space and lifecycle service. Keep the model reference unchanged in replacement documentation. Check environmental limits in the original product data.

Application Industry

Frequently Asked Questions

What rated voltage is listed for K3G200-AG16-I3?

The upload row lists 230 VAC. Confirm phase, frequency, terminals, and local supply conditions before wiring.

What should I check if K3G200-AG16-I3 develops a cooling fault?

Check supply voltage, controller signals, blocked airflow, contamination, abnormal noise, rotation, and the equipment operating point before replacing the unit.

Which supplied feature distinguishes K3G200-AG16-I3?

The matched source highlights a compact construction intended to simplify equipment integration. Compare that point together with the listed electrical and dimensional data.

Does K3G200-AG16-I3 require a separate controller?

The series information indicates controllability, but whether a separate controller is needed depends on the exact motor and integrated electronics.

Is K3G200-AG16-I3 suitable for a high-reliability cooling system?

It may be evaluated for high-reliability cooling using the supplied parameters, but duty cycle, redundancy, ambient limits, and protection must be confirmed at system level.

What should be checked before installing K3G200-AG16-I3?

Check electrical supply, mounting clearance, fasteners, airflow direction, guards, wiring, and access for service before installation.