Applied in Automation, the ebm-papst R2E220-AA40-F6 is a 230 V AC forward-curved centrifugal fan, whose supplied data highlights a documented 90 W input rating. The rating aids system-fit checks.
| Rated Voltage(V) | 230 |
|---|---|
| Size(mm) | 220 |
| Max.Air Flow(m³/h) | 895 |
| Max.Pressure(Pa) | 220 |
| Input Power(W) | 90 |
| Speed(rpm) | 2700 |
R2E220-AA40-F6 is an ebm-papst AC centrifugal fan for Automation, where controlled heat removal and airflow management must match the actual duty point. Its model-specific format supports OEM builds, retrofit planning and replacement sourcing.
Documented selection points include 230 V supply, 90 W input, 220 mm size, up to 895 m3/h airflow. These values support electrical, envelope and duty-point comparison.
For procurement, verify voltage, duty point, dimensions, connector and mounting. Correct sizing and clear airflow paths support stable operation, controlled noise and long service life. Confirm speed control, IP protection and approvals in the exact-model datasheet. It supports applications that prioritize reliable operation and maintainable design.
The ebm-papst R2E220-AA40-F6 from the EC Centrifugal series is a direct energy-saving replacement for legacy AC fans including R2D, R4E. Key benefits:
R2E EC fans operate at V with W rated power. When replacing AC models, wire the 0-10V control signal alongside the standard three-phase power cable.
How the R2E220-AA40-F6 compares to nearby R2E series variants:
| Model | R2E133-BH66-05 | R2E133-BH66-05/A01 | R2E133-BH66-05/A02 | R2E133-BH66-07 |
|---|---|---|---|---|
| Air Flow | 290 m³/h | — | 340 m³/h | 240 m³/h |
| Power | 24 W | 27 W | 27 W | 25 W |
| Noise | — dB | — dB | — dB | — dB |
| Size | 133 mm | 133 mm | 133 mm | 133 mm |
All R2E series fans from Hengrui include performance curves, mounting instructions and factory warranty. Contact us for project-specific selection.
Data Center CRAH/CRAC Units: The R2E220-AA40-F6 delivers reliable cooling for Computer Room Air Handling with 24/7 uptime. EC motor enables precise temperature control.
AHU Air Handling: Engineered for integration into Air Handling Units.
Industrial Process Ventilation: Machinery cooling, enclosure ventilation and process air movement. Hengrui provides custom engineering support.
Its AC forward-curved centrifugal fan configuration and a documented 90 W input rating provide model-specific criteria for matching Automation systems.
The supplied table lists 895 m³/h, 220 Pa, 2,700 rpm; use the exact datasheet for the complete operating curve.
Continuous operation must remain within the published electrical, thermal and aerodynamic limits; confirm the exact datasheet and system conditions.
Correct sizing and operation within documented limits can reduce avoidable thermal stress and maintenance events; project savings require duty-cycle analysis.

Applied in Air Purification, the ebm-papst R3G355-AI56-08 is a 380-480V EC backward-curved centrifugal fan, documented with a listed pressure capability of 775 Pa. The data supports model-level evaluation.
Read More
Used in Air Purification, the ebm-papst R3G310-RR12-P1 is a 110 V EC backward-curved centrifugal fan, with a focus on a listed pressure capability of 600 Pa. This assists electrical and mechanical review.
Read More
Designed for Air Purification, the ebm-papst R3G250-RR15-P2 is a 80 V EC backward-curved centrifugal fan, with a documented speed of 3,600 rpm. The rating clarifies its operating profile.
Read More
Designed for Air Purification, the ebm-papst R3G250-RE07-07 is a 200-277V EC backward-curved centrifugal fan, identified by a listed acoustic value of 59 dB. It gives engineers a clear comparison point.
Read More
Used in Air Purification, the ebm-papst R3G225-RE09-06 is a 200-277V EC backward-curved centrifugal fan, whose supplied data highlights a documented speed of 2,725 rpm. It provides a practical sizing reference.
Read More
Specified for Air Purification, ebm-papst R3G220-RD53-03 is a 200-277V EC backward-curved centrifugal fan, with a documented speed of 3,230 rpm. The rating aids system-fit checks. Its documented data supports integration planning.
Read More